732 Examining Staff Views and Perceptions After Implementation of a Laser Doppler Imaging Device Into Practice

INTRODUCTION: Laser doppler imaging (LDI) has been established as an accurate diagnostic tool to assess burn depth and measure healing potential. Despite this, its use in burn centers remain limited. While studies have examined challenges to LDI use, there is a paucity of literature factoring staff...

Descripción completa

Detalles Bibliográficos
Autores principales: Tejiram, Shawn, Washburn, Thomas, Shupp, Jeffrey W
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946511/
http://dx.doi.org/10.1093/jbcr/irac012.286
_version_ 1784674210911617024
author Tejiram, Shawn
Washburn, Thomas
Shupp, Jeffrey W
author_facet Tejiram, Shawn
Washburn, Thomas
Shupp, Jeffrey W
author_sort Tejiram, Shawn
collection PubMed
description INTRODUCTION: Laser doppler imaging (LDI) has been established as an accurate diagnostic tool to assess burn depth and measure healing potential. Despite this, its use in burn centers remain limited. While studies have examined challenges to LDI use, there is a paucity of literature factoring staff views and attitudes as a barrier to implementation into burn practice. The aim of this work was to assess and examine attitudes and perspectives following implementation of an LDI protocol into acute burn injury assessment. METHODS: Following institutional approval, a 22-question survey was disseminated among staff involved with implementation of an LDI device as a point of care tool to assess acute burn injury at a single ABA verified burn center. The survey focused on questions examining device ease of use, understanding of the underlying LDI technology, interpretation of imaging generation from wounds, and perceptions of patients’ experience. Questions were answered on a standard 5-point Likert scale. All survey data was collected anonymously into an electronic database for assessment. RESULTS: Overall, there were 15 respondents to the survey questions. Five respondents found the LDI device difficult to use (33%). Barriers to device ease of use included difficulty with device movement (60%), incorporation of scanning into wound care and dressing placement (60%), and management of hardware or software issues that arise during use (60%). Challenges noted by respondents external to device use was mainly high patient census (80%). Despite this, 60% of respondents found the device easier to use after performing several scans in one or more patients and 60% found that scans generated matched their assessment of burn depth. Among respondents, 66% found patients amenable to the scanning process and 80% did not feel that that the scanning process worsened patients’ pain. CONCLUSIONS: Challenges in LDI device use, implementation with wound care and dressing placement, and high patient census were identified as barriers to LDI use. Despite this, ease of device use improved with more frequent use. Identification of views and perceptions such as these can lead to protocol changes and additional training that facilitate ease of LDI use. Further examination will be required to better elucidate this information.
format Online
Article
Text
id pubmed-8946511
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-89465112022-03-28 732 Examining Staff Views and Perceptions After Implementation of a Laser Doppler Imaging Device Into Practice Tejiram, Shawn Washburn, Thomas Shupp, Jeffrey W J Burn Care Res Medical Care, Non-critical 2 INTRODUCTION: Laser doppler imaging (LDI) has been established as an accurate diagnostic tool to assess burn depth and measure healing potential. Despite this, its use in burn centers remain limited. While studies have examined challenges to LDI use, there is a paucity of literature factoring staff views and attitudes as a barrier to implementation into burn practice. The aim of this work was to assess and examine attitudes and perspectives following implementation of an LDI protocol into acute burn injury assessment. METHODS: Following institutional approval, a 22-question survey was disseminated among staff involved with implementation of an LDI device as a point of care tool to assess acute burn injury at a single ABA verified burn center. The survey focused on questions examining device ease of use, understanding of the underlying LDI technology, interpretation of imaging generation from wounds, and perceptions of patients’ experience. Questions were answered on a standard 5-point Likert scale. All survey data was collected anonymously into an electronic database for assessment. RESULTS: Overall, there were 15 respondents to the survey questions. Five respondents found the LDI device difficult to use (33%). Barriers to device ease of use included difficulty with device movement (60%), incorporation of scanning into wound care and dressing placement (60%), and management of hardware or software issues that arise during use (60%). Challenges noted by respondents external to device use was mainly high patient census (80%). Despite this, 60% of respondents found the device easier to use after performing several scans in one or more patients and 60% found that scans generated matched their assessment of burn depth. Among respondents, 66% found patients amenable to the scanning process and 80% did not feel that that the scanning process worsened patients’ pain. CONCLUSIONS: Challenges in LDI device use, implementation with wound care and dressing placement, and high patient census were identified as barriers to LDI use. Despite this, ease of device use improved with more frequent use. Identification of views and perceptions such as these can lead to protocol changes and additional training that facilitate ease of LDI use. Further examination will be required to better elucidate this information. Oxford University Press 2022-03-23 /pmc/articles/PMC8946511/ http://dx.doi.org/10.1093/jbcr/irac012.286 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the American Burn Association. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Care, Non-critical 2
Tejiram, Shawn
Washburn, Thomas
Shupp, Jeffrey W
732 Examining Staff Views and Perceptions After Implementation of a Laser Doppler Imaging Device Into Practice
title 732 Examining Staff Views and Perceptions After Implementation of a Laser Doppler Imaging Device Into Practice
title_full 732 Examining Staff Views and Perceptions After Implementation of a Laser Doppler Imaging Device Into Practice
title_fullStr 732 Examining Staff Views and Perceptions After Implementation of a Laser Doppler Imaging Device Into Practice
title_full_unstemmed 732 Examining Staff Views and Perceptions After Implementation of a Laser Doppler Imaging Device Into Practice
title_short 732 Examining Staff Views and Perceptions After Implementation of a Laser Doppler Imaging Device Into Practice
title_sort 732 examining staff views and perceptions after implementation of a laser doppler imaging device into practice
topic Medical Care, Non-critical 2
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946511/
http://dx.doi.org/10.1093/jbcr/irac012.286
work_keys_str_mv AT tejiramshawn 732examiningstaffviewsandperceptionsafterimplementationofalaserdopplerimagingdeviceintopractice
AT washburnthomas 732examiningstaffviewsandperceptionsafterimplementationofalaserdopplerimagingdeviceintopractice
AT shuppjeffreyw 732examiningstaffviewsandperceptionsafterimplementationofalaserdopplerimagingdeviceintopractice