Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber
A compact surface plasmon resonance sensor based on an H-shaped optical fiber is proposed and demonstrated. The H-shaped optical fiber was fabricated experimentally by using hydrofluoric acid to controllably corrode the polarization-maintaining fiber. A satisfactory distance between the outer surfac...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946733/ https://www.ncbi.nlm.nih.gov/pubmed/35323411 http://dx.doi.org/10.3390/bios12030141 |
_version_ | 1784674262380969984 |
---|---|
author | Huang, Yijian Wang, Ying Xu, Gaixia Rao, Xing Zhang, Jiaxiong Wu, Xun Liao, Changrui Wang, Yiping |
author_facet | Huang, Yijian Wang, Ying Xu, Gaixia Rao, Xing Zhang, Jiaxiong Wu, Xun Liao, Changrui Wang, Yiping |
author_sort | Huang, Yijian |
collection | PubMed |
description | A compact surface plasmon resonance sensor based on an H-shaped optical fiber is proposed and demonstrated. The H-shaped optical fiber was fabricated experimentally by using hydrofluoric acid to controllably corrode the polarization-maintaining fiber. A satisfactory distance between the outer surface of the fiber and the core can be achieved, and then the surface plasmon resonance effect can be excited by coating a metal film of appropriate thickness on the surface of the fiber. This technology can realize the preparation of multiple samples at one time, compared to the traditional side-polishing technique. The H-shaped optical fiber obtained from corrosion exhibits a high surface quality and short lengths, down to only a few hundred microns. The effects of the proposed H-shaped optical fiber on spectral properties are induced by process parameters, including fiber remaining thickness, coating thickness and fiber length, and were investigated in detail. The prepared sensor was used for the specific detection of human IgG, and the minimum human IgG concentration that the sensor can distinguish is 3.4 μg/mL. Such a compact surface plasmon resonance fiber sensor has the advantages of an easy fabrication, good consistency and low cost, and is expected to be applied in the specific detection of biomarkers. |
format | Online Article Text |
id | pubmed-8946733 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89467332022-03-25 Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber Huang, Yijian Wang, Ying Xu, Gaixia Rao, Xing Zhang, Jiaxiong Wu, Xun Liao, Changrui Wang, Yiping Biosensors (Basel) Article A compact surface plasmon resonance sensor based on an H-shaped optical fiber is proposed and demonstrated. The H-shaped optical fiber was fabricated experimentally by using hydrofluoric acid to controllably corrode the polarization-maintaining fiber. A satisfactory distance between the outer surface of the fiber and the core can be achieved, and then the surface plasmon resonance effect can be excited by coating a metal film of appropriate thickness on the surface of the fiber. This technology can realize the preparation of multiple samples at one time, compared to the traditional side-polishing technique. The H-shaped optical fiber obtained from corrosion exhibits a high surface quality and short lengths, down to only a few hundred microns. The effects of the proposed H-shaped optical fiber on spectral properties are induced by process parameters, including fiber remaining thickness, coating thickness and fiber length, and were investigated in detail. The prepared sensor was used for the specific detection of human IgG, and the minimum human IgG concentration that the sensor can distinguish is 3.4 μg/mL. Such a compact surface plasmon resonance fiber sensor has the advantages of an easy fabrication, good consistency and low cost, and is expected to be applied in the specific detection of biomarkers. MDPI 2022-02-25 /pmc/articles/PMC8946733/ /pubmed/35323411 http://dx.doi.org/10.3390/bios12030141 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Huang, Yijian Wang, Ying Xu, Gaixia Rao, Xing Zhang, Jiaxiong Wu, Xun Liao, Changrui Wang, Yiping Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber |
title | Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber |
title_full | Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber |
title_fullStr | Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber |
title_full_unstemmed | Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber |
title_short | Compact Surface Plasmon Resonance IgG Sensor Based on H-Shaped Optical Fiber |
title_sort | compact surface plasmon resonance igg sensor based on h-shaped optical fiber |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946733/ https://www.ncbi.nlm.nih.gov/pubmed/35323411 http://dx.doi.org/10.3390/bios12030141 |
work_keys_str_mv | AT huangyijian compactsurfaceplasmonresonanceiggsensorbasedonhshapedopticalfiber AT wangying compactsurfaceplasmonresonanceiggsensorbasedonhshapedopticalfiber AT xugaixia compactsurfaceplasmonresonanceiggsensorbasedonhshapedopticalfiber AT raoxing compactsurfaceplasmonresonanceiggsensorbasedonhshapedopticalfiber AT zhangjiaxiong compactsurfaceplasmonresonanceiggsensorbasedonhshapedopticalfiber AT wuxun compactsurfaceplasmonresonanceiggsensorbasedonhshapedopticalfiber AT liaochangrui compactsurfaceplasmonresonanceiggsensorbasedonhshapedopticalfiber AT wangyiping compactsurfaceplasmonresonanceiggsensorbasedonhshapedopticalfiber |