Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography

This study aims to investigate differences in the mean corneal power of annular zones (corneal power measured over the inner annular zone of difference diameters) and rings (corneal power measured over a ring of different diameters) centered on the corneal apex using the swept-source optical coheren...

Descripción completa

Detalles Bibliográficos
Autores principales: Dong, Jing, Yao, Jinhan, Chang, Shuimiao, Kanclerz, Piotr, Khoramnia, Ramin, Wang, Xiaogang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946905/
https://www.ncbi.nlm.nih.gov/pubmed/35328307
http://dx.doi.org/10.3390/diagnostics12030754
_version_ 1784674303387631616
author Dong, Jing
Yao, Jinhan
Chang, Shuimiao
Kanclerz, Piotr
Khoramnia, Ramin
Wang, Xiaogang
author_facet Dong, Jing
Yao, Jinhan
Chang, Shuimiao
Kanclerz, Piotr
Khoramnia, Ramin
Wang, Xiaogang
author_sort Dong, Jing
collection PubMed
description This study aims to investigate differences in the mean corneal power of annular zones (corneal power measured over the inner annular zone of difference diameters) and rings (corneal power measured over a ring of different diameters) centered on the corneal apex using the swept-source optical coherence tomography technique. The mean anterior axial curvature (AAC), posterior axial curvature (PAC), and total corneal power (TCP) centered on the corneal apex with the annular rings (0–2 mm, 2–4 mm, 4–6 mm, and 6–8 mm) and zones were assessed using the ANTERION device. The paired-sample t-test was used for data comparison. For the 0–2 mm comparison, the AAC, PAC, and TCP values of rings and zones were interchangeable. For the 2–4 mm comparison, the AAC of the rings was lower than that of the zones (p = 0.004), and the TCP values of the rings were higher than that of the zones (p < 0.001). For the 4–6 mm comparison, the AAC of the rings was lower than that of the zones (p < 0.001), and the PAC and TCP values of the rings were higher than that of the zones (both p < 0.001). For the 6–8 mm comparison, the AAC of the rings was lower than that of the zones (p < 0.001), and the PAC and TCP values of the rings were higher than that of the zones (both p < 0.001). Comparisons between AAC and TCP in each sub-region showed significant differences both in the rings (p < 0.001) and the zones (p < 0.008). Differences in the AAC, PAC, and TCP measured at different diameters (2–4 mm, 4–6 mm, and 6–8 mm) of the rings and zones, centered on the corneal apex, should be noticed in clinical practice. As the diameter increases, the difference between the rings and the zones in terms of AAC, PAC, and TCP increase as well. Clinicians should also pay attention to differences between AAC and TCP for the rings and the zones within the same annular region.
format Online
Article
Text
id pubmed-8946905
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89469052022-03-25 Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography Dong, Jing Yao, Jinhan Chang, Shuimiao Kanclerz, Piotr Khoramnia, Ramin Wang, Xiaogang Diagnostics (Basel) Article This study aims to investigate differences in the mean corneal power of annular zones (corneal power measured over the inner annular zone of difference diameters) and rings (corneal power measured over a ring of different diameters) centered on the corneal apex using the swept-source optical coherence tomography technique. The mean anterior axial curvature (AAC), posterior axial curvature (PAC), and total corneal power (TCP) centered on the corneal apex with the annular rings (0–2 mm, 2–4 mm, 4–6 mm, and 6–8 mm) and zones were assessed using the ANTERION device. The paired-sample t-test was used for data comparison. For the 0–2 mm comparison, the AAC, PAC, and TCP values of rings and zones were interchangeable. For the 2–4 mm comparison, the AAC of the rings was lower than that of the zones (p = 0.004), and the TCP values of the rings were higher than that of the zones (p < 0.001). For the 4–6 mm comparison, the AAC of the rings was lower than that of the zones (p < 0.001), and the PAC and TCP values of the rings were higher than that of the zones (both p < 0.001). For the 6–8 mm comparison, the AAC of the rings was lower than that of the zones (p < 0.001), and the PAC and TCP values of the rings were higher than that of the zones (both p < 0.001). Comparisons between AAC and TCP in each sub-region showed significant differences both in the rings (p < 0.001) and the zones (p < 0.008). Differences in the AAC, PAC, and TCP measured at different diameters (2–4 mm, 4–6 mm, and 6–8 mm) of the rings and zones, centered on the corneal apex, should be noticed in clinical practice. As the diameter increases, the difference between the rings and the zones in terms of AAC, PAC, and TCP increase as well. Clinicians should also pay attention to differences between AAC and TCP for the rings and the zones within the same annular region. MDPI 2022-03-19 /pmc/articles/PMC8946905/ /pubmed/35328307 http://dx.doi.org/10.3390/diagnostics12030754 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dong, Jing
Yao, Jinhan
Chang, Shuimiao
Kanclerz, Piotr
Khoramnia, Ramin
Wang, Xiaogang
Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography
title Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography
title_full Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography
title_fullStr Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography
title_full_unstemmed Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography
title_short Comparison of Mean Corneal Power of Annular Rings and Zones Using Swept-Source Optical Coherence Tomography
title_sort comparison of mean corneal power of annular rings and zones using swept-source optical coherence tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946905/
https://www.ncbi.nlm.nih.gov/pubmed/35328307
http://dx.doi.org/10.3390/diagnostics12030754
work_keys_str_mv AT dongjing comparisonofmeancornealpowerofannularringsandzonesusingsweptsourceopticalcoherencetomography
AT yaojinhan comparisonofmeancornealpowerofannularringsandzonesusingsweptsourceopticalcoherencetomography
AT changshuimiao comparisonofmeancornealpowerofannularringsandzonesusingsweptsourceopticalcoherencetomography
AT kanclerzpiotr comparisonofmeancornealpowerofannularringsandzonesusingsweptsourceopticalcoherencetomography
AT khoramniaramin comparisonofmeancornealpowerofannularringsandzonesusingsweptsourceopticalcoherencetomography
AT wangxiaogang comparisonofmeancornealpowerofannularringsandzonesusingsweptsourceopticalcoherencetomography