Cargando…

Effectiveness and Safety of Real-Time Transthoracic Ultrasound-Guided Thoracentesis

Purpose: The purpose of the present study was to specifically evaluate the effectiveness and safety of real-time ultrasound-guided thoracentesis in a case series of pleural effusion. Patients and methods: An observational prospective study was conducted. From February 2018 to December 2019, a total...

Descripción completa

Detalles Bibliográficos
Autores principales: Sperandeo, Marco, Quarato, Carla Maria Irene, Squatrito, Rosario, Fuso, Paolo, Dimitri, Lucia, Simeone, Anna, Notarangelo, Stefano, Lacedonia, Donato
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946970/
https://www.ncbi.nlm.nih.gov/pubmed/35328278
http://dx.doi.org/10.3390/diagnostics12030725
_version_ 1784674326032678912
author Sperandeo, Marco
Quarato, Carla Maria Irene
Squatrito, Rosario
Fuso, Paolo
Dimitri, Lucia
Simeone, Anna
Notarangelo, Stefano
Lacedonia, Donato
author_facet Sperandeo, Marco
Quarato, Carla Maria Irene
Squatrito, Rosario
Fuso, Paolo
Dimitri, Lucia
Simeone, Anna
Notarangelo, Stefano
Lacedonia, Donato
author_sort Sperandeo, Marco
collection PubMed
description Purpose: The purpose of the present study was to specifically evaluate the effectiveness and safety of real-time ultrasound-guided thoracentesis in a case series of pleural effusion. Patients and methods: An observational prospective study was conducted. From February 2018 to December 2019, a total of 361 consecutive real-time transthoracic ultrasound (TUS)-guided thoracentesis were performed in the Unit of Diagnostic and Interventional Ultrasound of the Research Hospital “Fondazione Casa Sollievo della Sofferenza” of San Giovanni Rotondo, Foggia, Italy. The primary indication for thoracentesis was therapeutic in all the cases (i.e., evacuation of persistent small/moderate pleural effusions to avoid super-infection; drainage of symptomatic moderate/massive effusions). For completeness, further diagnostic investigations (including chemical, microbiological, and cytological analysis) were conducted. All the procedures were performed by two internists with more than 30 years of experience in interventional ultrasound using a multifrequency convex probe (3–8 MHz). For pleural effusions with a depth of 2–3 cm measured at the level of the costo-phrenic sinus was employed a dedicated holed convex-array probe (5 MHz). Results: In all the cases, the attempts at thoracentesis were successful, allowing the achievement of the therapeutic purpose of the procedure (i.e., the complete drying of the pleural space or the withdrawal of fluid till a “safe” quantity [a mean of 1.5 L, max 2 L] producing relief from symptoms) regardless of the initial extent of the pleural effusion. There were only 3 cases of pneumothorax, for a prevalence rate of complications in this population of 0.83%. No statistical difference was recorded in the rate of pneumothorax according to the initial amount of pleural fluid in the effusion (p = 0.12). All the pleural effusions classified as transudates showed an anechoic TUS appearance. Only the exudative effusions showed a complex nonseptated or a hyperechoic TUS appearance. However, an anechoic TUS pattern was not unequivocally associated with transudates. Some chronic transudates have been classified as exudates by Light’s criteria, showing also a complex nonseptated TUS appearance. The cytological examination of the drained fluid allowed the detection of neoplastic cells in 15.89% cases. On the other hand, the microbiological examination of effusions yielded negative results in all the cases. Conclusions: Real-time TUS-guided thoracentesis is a therapeutically effective and safe procedure, despite the diagnostic yield of the cytological or microbiological examinations on the collected liquid being very low. Future blinded randomized studies are required to definitely clarify the actual benefit of the real-time TUS-guided procedure over percussion-guided and other ultrasound-based procedures.
format Online
Article
Text
id pubmed-8946970
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89469702022-03-25 Effectiveness and Safety of Real-Time Transthoracic Ultrasound-Guided Thoracentesis Sperandeo, Marco Quarato, Carla Maria Irene Squatrito, Rosario Fuso, Paolo Dimitri, Lucia Simeone, Anna Notarangelo, Stefano Lacedonia, Donato Diagnostics (Basel) Article Purpose: The purpose of the present study was to specifically evaluate the effectiveness and safety of real-time ultrasound-guided thoracentesis in a case series of pleural effusion. Patients and methods: An observational prospective study was conducted. From February 2018 to December 2019, a total of 361 consecutive real-time transthoracic ultrasound (TUS)-guided thoracentesis were performed in the Unit of Diagnostic and Interventional Ultrasound of the Research Hospital “Fondazione Casa Sollievo della Sofferenza” of San Giovanni Rotondo, Foggia, Italy. The primary indication for thoracentesis was therapeutic in all the cases (i.e., evacuation of persistent small/moderate pleural effusions to avoid super-infection; drainage of symptomatic moderate/massive effusions). For completeness, further diagnostic investigations (including chemical, microbiological, and cytological analysis) were conducted. All the procedures were performed by two internists with more than 30 years of experience in interventional ultrasound using a multifrequency convex probe (3–8 MHz). For pleural effusions with a depth of 2–3 cm measured at the level of the costo-phrenic sinus was employed a dedicated holed convex-array probe (5 MHz). Results: In all the cases, the attempts at thoracentesis were successful, allowing the achievement of the therapeutic purpose of the procedure (i.e., the complete drying of the pleural space or the withdrawal of fluid till a “safe” quantity [a mean of 1.5 L, max 2 L] producing relief from symptoms) regardless of the initial extent of the pleural effusion. There were only 3 cases of pneumothorax, for a prevalence rate of complications in this population of 0.83%. No statistical difference was recorded in the rate of pneumothorax according to the initial amount of pleural fluid in the effusion (p = 0.12). All the pleural effusions classified as transudates showed an anechoic TUS appearance. Only the exudative effusions showed a complex nonseptated or a hyperechoic TUS appearance. However, an anechoic TUS pattern was not unequivocally associated with transudates. Some chronic transudates have been classified as exudates by Light’s criteria, showing also a complex nonseptated TUS appearance. The cytological examination of the drained fluid allowed the detection of neoplastic cells in 15.89% cases. On the other hand, the microbiological examination of effusions yielded negative results in all the cases. Conclusions: Real-time TUS-guided thoracentesis is a therapeutically effective and safe procedure, despite the diagnostic yield of the cytological or microbiological examinations on the collected liquid being very low. Future blinded randomized studies are required to definitely clarify the actual benefit of the real-time TUS-guided procedure over percussion-guided and other ultrasound-based procedures. MDPI 2022-03-16 /pmc/articles/PMC8946970/ /pubmed/35328278 http://dx.doi.org/10.3390/diagnostics12030725 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sperandeo, Marco
Quarato, Carla Maria Irene
Squatrito, Rosario
Fuso, Paolo
Dimitri, Lucia
Simeone, Anna
Notarangelo, Stefano
Lacedonia, Donato
Effectiveness and Safety of Real-Time Transthoracic Ultrasound-Guided Thoracentesis
title Effectiveness and Safety of Real-Time Transthoracic Ultrasound-Guided Thoracentesis
title_full Effectiveness and Safety of Real-Time Transthoracic Ultrasound-Guided Thoracentesis
title_fullStr Effectiveness and Safety of Real-Time Transthoracic Ultrasound-Guided Thoracentesis
title_full_unstemmed Effectiveness and Safety of Real-Time Transthoracic Ultrasound-Guided Thoracentesis
title_short Effectiveness and Safety of Real-Time Transthoracic Ultrasound-Guided Thoracentesis
title_sort effectiveness and safety of real-time transthoracic ultrasound-guided thoracentesis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946970/
https://www.ncbi.nlm.nih.gov/pubmed/35328278
http://dx.doi.org/10.3390/diagnostics12030725
work_keys_str_mv AT sperandeomarco effectivenessandsafetyofrealtimetransthoracicultrasoundguidedthoracentesis
AT quaratocarlamariairene effectivenessandsafetyofrealtimetransthoracicultrasoundguidedthoracentesis
AT squatritorosario effectivenessandsafetyofrealtimetransthoracicultrasoundguidedthoracentesis
AT fusopaolo effectivenessandsafetyofrealtimetransthoracicultrasoundguidedthoracentesis
AT dimitrilucia effectivenessandsafetyofrealtimetransthoracicultrasoundguidedthoracentesis
AT simeoneanna effectivenessandsafetyofrealtimetransthoracicultrasoundguidedthoracentesis
AT notarangelostefano effectivenessandsafetyofrealtimetransthoracicultrasoundguidedthoracentesis
AT lacedoniadonato effectivenessandsafetyofrealtimetransthoracicultrasoundguidedthoracentesis