Cargando…

Evaluation of Computer-Aided Detection (CAD) in Screening Automated Breast Ultrasound Based on Characteristics of CAD Marks and False-Positive Marks

The present study evaluated the effectiveness of computer-aided detection (CAD) system in screening automated breast ultrasound (ABUS) and analyzed the characteristics of CAD marks and the causes of false-positive marks. A total of 846 women who underwent ABUS for screening from January 2017 to Dece...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jeongmin, Kang, Bong Joo, Kim, Sung Hun, Park, Ga Eun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8947351/
https://www.ncbi.nlm.nih.gov/pubmed/35328136
http://dx.doi.org/10.3390/diagnostics12030583
_version_ 1784674418659688448
author Lee, Jeongmin
Kang, Bong Joo
Kim, Sung Hun
Park, Ga Eun
author_facet Lee, Jeongmin
Kang, Bong Joo
Kim, Sung Hun
Park, Ga Eun
author_sort Lee, Jeongmin
collection PubMed
description The present study evaluated the effectiveness of computer-aided detection (CAD) system in screening automated breast ultrasound (ABUS) and analyzed the characteristics of CAD marks and the causes of false-positive marks. A total of 846 women who underwent ABUS for screening from January 2017 to December 2017 were included. Commercial CAD was used in all ABUS examinations, and its diagnostic performance and efficacy in shortening the reading time (RT) were evaluated. In addition, we analyzed the characteristics of CAD marks and the causes of false-positive marks. A total of 1032 CAD marks were displayed based on the patient and 534 CAD marks on the lesion. Five cases of breast cancer were diagnosed. The sensitivity, specificity, PPV, and NPV of CAD were 60.0%, 59.0%, 0.9%, and 99.6% for 846 patients. In the case of a negative study, it was less time-consuming and easier to make a decision. Among 530 false-positive marks, 459 were identified clearly for pseudo-lesions; the most common cause was marginal shadowing, followed by Cooper’s ligament shadowing, peri-areolar shadowing, rib, and skin lesions. Even though CAD does not improve the performance of ABUS and a large number of false-positive marks were detected, the addition of CAD reduces RT, especially in the case of negative screening ultrasound.
format Online
Article
Text
id pubmed-8947351
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89473512022-03-25 Evaluation of Computer-Aided Detection (CAD) in Screening Automated Breast Ultrasound Based on Characteristics of CAD Marks and False-Positive Marks Lee, Jeongmin Kang, Bong Joo Kim, Sung Hun Park, Ga Eun Diagnostics (Basel) Article The present study evaluated the effectiveness of computer-aided detection (CAD) system in screening automated breast ultrasound (ABUS) and analyzed the characteristics of CAD marks and the causes of false-positive marks. A total of 846 women who underwent ABUS for screening from January 2017 to December 2017 were included. Commercial CAD was used in all ABUS examinations, and its diagnostic performance and efficacy in shortening the reading time (RT) were evaluated. In addition, we analyzed the characteristics of CAD marks and the causes of false-positive marks. A total of 1032 CAD marks were displayed based on the patient and 534 CAD marks on the lesion. Five cases of breast cancer were diagnosed. The sensitivity, specificity, PPV, and NPV of CAD were 60.0%, 59.0%, 0.9%, and 99.6% for 846 patients. In the case of a negative study, it was less time-consuming and easier to make a decision. Among 530 false-positive marks, 459 were identified clearly for pseudo-lesions; the most common cause was marginal shadowing, followed by Cooper’s ligament shadowing, peri-areolar shadowing, rib, and skin lesions. Even though CAD does not improve the performance of ABUS and a large number of false-positive marks were detected, the addition of CAD reduces RT, especially in the case of negative screening ultrasound. MDPI 2022-02-24 /pmc/articles/PMC8947351/ /pubmed/35328136 http://dx.doi.org/10.3390/diagnostics12030583 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Jeongmin
Kang, Bong Joo
Kim, Sung Hun
Park, Ga Eun
Evaluation of Computer-Aided Detection (CAD) in Screening Automated Breast Ultrasound Based on Characteristics of CAD Marks and False-Positive Marks
title Evaluation of Computer-Aided Detection (CAD) in Screening Automated Breast Ultrasound Based on Characteristics of CAD Marks and False-Positive Marks
title_full Evaluation of Computer-Aided Detection (CAD) in Screening Automated Breast Ultrasound Based on Characteristics of CAD Marks and False-Positive Marks
title_fullStr Evaluation of Computer-Aided Detection (CAD) in Screening Automated Breast Ultrasound Based on Characteristics of CAD Marks and False-Positive Marks
title_full_unstemmed Evaluation of Computer-Aided Detection (CAD) in Screening Automated Breast Ultrasound Based on Characteristics of CAD Marks and False-Positive Marks
title_short Evaluation of Computer-Aided Detection (CAD) in Screening Automated Breast Ultrasound Based on Characteristics of CAD Marks and False-Positive Marks
title_sort evaluation of computer-aided detection (cad) in screening automated breast ultrasound based on characteristics of cad marks and false-positive marks
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8947351/
https://www.ncbi.nlm.nih.gov/pubmed/35328136
http://dx.doi.org/10.3390/diagnostics12030583
work_keys_str_mv AT leejeongmin evaluationofcomputeraideddetectioncadinscreeningautomatedbreastultrasoundbasedoncharacteristicsofcadmarksandfalsepositivemarks
AT kangbongjoo evaluationofcomputeraideddetectioncadinscreeningautomatedbreastultrasoundbasedoncharacteristicsofcadmarksandfalsepositivemarks
AT kimsunghun evaluationofcomputeraideddetectioncadinscreeningautomatedbreastultrasoundbasedoncharacteristicsofcadmarksandfalsepositivemarks
AT parkgaeun evaluationofcomputeraideddetectioncadinscreeningautomatedbreastultrasoundbasedoncharacteristicsofcadmarksandfalsepositivemarks