Cargando…

Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging

V Flow is commercially developed by high-frame-rate ultrasound vector flow imaging. Compared to conventional color Doppler, V Flow is angle-independent and is capable of measuring both the magnitude and the direction of blood flow velocities. This paper aims to investigate the differences between V...

Descripción completa

Detalles Bibliográficos
Autores principales: Du, Yigang, Ding, Haiyan, He, Le, Yiu, Billy Y. S., Deng, Linsong, Yu, Alfred C. H., Zhu, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8947594/
https://www.ncbi.nlm.nih.gov/pubmed/35328242
http://dx.doi.org/10.3390/diagnostics12030690
_version_ 1784674477204832256
author Du, Yigang
Ding, Haiyan
He, Le
Yiu, Billy Y. S.
Deng, Linsong
Yu, Alfred C. H.
Zhu, Lei
author_facet Du, Yigang
Ding, Haiyan
He, Le
Yiu, Billy Y. S.
Deng, Linsong
Yu, Alfred C. H.
Zhu, Lei
author_sort Du, Yigang
collection PubMed
description V Flow is commercially developed by high-frame-rate ultrasound vector flow imaging. Compared to conventional color Doppler, V Flow is angle-independent and is capable of measuring both the magnitude and the direction of blood flow velocities. This paper aims to investigate the differences between V Flow and pulsed wave Doppler (PW) relative to phase contrast magnetic resonance imaging (PC-MRI), for the quantitative measurements of blood flow in common carotid arteries (CCA) and, consequently, to evaluate the accuracy of the new technique, V Flow. Sixty-four CCAs were measured using V Flow, PW, and PC-MRI. The maximum velocities, time-averaged mean (TAMEAN) velocities, and volume flow were measured using different imaging technologies. The mean error with standard deviation (Std), the median of absolute errors, and the r-values between V Flow and PC-MRI results for the maximum velocity, the TAMEAN velocity, and the volume flow measurements are {9.40% ± 14.91%; 11.84%; 0.84}, {21.52% ± 14.46%; 19.28%; 0.86}, and {−2.80% ± 14.01%; 10.38%; 0.7}, respectively, and are {53.44% ± 29.68%; 49.79%; 0.74}, {27.83% ± 31.60%; 23.83; 0.71}, and {21.01% ± 29.64%; 25.48%; 0.34}, respectively, for those between PW and PC-MRI. The boxplot, linear regression and Bland–Altman plots were performed for each comparison, which illustrated that the results measured via V Flow rather than via PW agreed more closely with those measured via PC-MRI.
format Online
Article
Text
id pubmed-8947594
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89475942022-03-25 Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging Du, Yigang Ding, Haiyan He, Le Yiu, Billy Y. S. Deng, Linsong Yu, Alfred C. H. Zhu, Lei Diagnostics (Basel) Article V Flow is commercially developed by high-frame-rate ultrasound vector flow imaging. Compared to conventional color Doppler, V Flow is angle-independent and is capable of measuring both the magnitude and the direction of blood flow velocities. This paper aims to investigate the differences between V Flow and pulsed wave Doppler (PW) relative to phase contrast magnetic resonance imaging (PC-MRI), for the quantitative measurements of blood flow in common carotid arteries (CCA) and, consequently, to evaluate the accuracy of the new technique, V Flow. Sixty-four CCAs were measured using V Flow, PW, and PC-MRI. The maximum velocities, time-averaged mean (TAMEAN) velocities, and volume flow were measured using different imaging technologies. The mean error with standard deviation (Std), the median of absolute errors, and the r-values between V Flow and PC-MRI results for the maximum velocity, the TAMEAN velocity, and the volume flow measurements are {9.40% ± 14.91%; 11.84%; 0.84}, {21.52% ± 14.46%; 19.28%; 0.86}, and {−2.80% ± 14.01%; 10.38%; 0.7}, respectively, and are {53.44% ± 29.68%; 49.79%; 0.74}, {27.83% ± 31.60%; 23.83; 0.71}, and {21.01% ± 29.64%; 25.48%; 0.34}, respectively, for those between PW and PC-MRI. The boxplot, linear regression and Bland–Altman plots were performed for each comparison, which illustrated that the results measured via V Flow rather than via PW agreed more closely with those measured via PC-MRI. MDPI 2022-03-11 /pmc/articles/PMC8947594/ /pubmed/35328242 http://dx.doi.org/10.3390/diagnostics12030690 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Du, Yigang
Ding, Haiyan
He, Le
Yiu, Billy Y. S.
Deng, Linsong
Yu, Alfred C. H.
Zhu, Lei
Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging
title Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging
title_full Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging
title_fullStr Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging
title_full_unstemmed Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging
title_short Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging
title_sort quantitative blood flow measurements in the common carotid artery: a comparative study of high-frame-rate ultrasound vector flow imaging, pulsed wave doppler, and phase contrast magnetic resonance imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8947594/
https://www.ncbi.nlm.nih.gov/pubmed/35328242
http://dx.doi.org/10.3390/diagnostics12030690
work_keys_str_mv AT duyigang quantitativebloodflowmeasurementsinthecommoncarotidarteryacomparativestudyofhighframerateultrasoundvectorflowimagingpulsedwavedopplerandphasecontrastmagneticresonanceimaging
AT dinghaiyan quantitativebloodflowmeasurementsinthecommoncarotidarteryacomparativestudyofhighframerateultrasoundvectorflowimagingpulsedwavedopplerandphasecontrastmagneticresonanceimaging
AT hele quantitativebloodflowmeasurementsinthecommoncarotidarteryacomparativestudyofhighframerateultrasoundvectorflowimagingpulsedwavedopplerandphasecontrastmagneticresonanceimaging
AT yiubillyys quantitativebloodflowmeasurementsinthecommoncarotidarteryacomparativestudyofhighframerateultrasoundvectorflowimagingpulsedwavedopplerandphasecontrastmagneticresonanceimaging
AT denglinsong quantitativebloodflowmeasurementsinthecommoncarotidarteryacomparativestudyofhighframerateultrasoundvectorflowimagingpulsedwavedopplerandphasecontrastmagneticresonanceimaging
AT yualfredch quantitativebloodflowmeasurementsinthecommoncarotidarteryacomparativestudyofhighframerateultrasoundvectorflowimagingpulsedwavedopplerandphasecontrastmagneticresonanceimaging
AT zhulei quantitativebloodflowmeasurementsinthecommoncarotidarteryacomparativestudyofhighframerateultrasoundvectorflowimagingpulsedwavedopplerandphasecontrastmagneticresonanceimaging