First Pediatric Pyeloplasty Using the Senhance(®) Robotic System—A Case Report

A pediatric robotic pyeloplasty has been performed with the Senhance(®) robotic system for the first time in January 2021 on a 1.5-year-old girl with symptomatic ureteropelvic junction stenosis. A Senhance(®) robotic system (Asensus Surgical(®) Inc., Durham, NC, USA) with three arms and 5 mm instrum...

Descripción completa

Detalles Bibliográficos
Autores principales: Holzer, Juergen, Beyer, Peter, Schilcher, Florian, Poth, Clemens, Stephan, Dietmar, von Schnakenburg, Christian, van Gemert, Wim, Staib, Ludger
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8947751/
https://www.ncbi.nlm.nih.gov/pubmed/35327674
http://dx.doi.org/10.3390/children9030302
Descripción
Sumario:A pediatric robotic pyeloplasty has been performed with the Senhance(®) robotic system for the first time in January 2021 on a 1.5-year-old girl with symptomatic ureteropelvic junction stenosis. A Senhance(®) robotic system (Asensus Surgical(®) Inc., Durham, NC, USA) with three arms and 5 mm instruments was used, providing infrared eye tracking of the 5 mm camera and haptic feedback for the surgeon, facilitating suturing of the anastomosis and double-J stent insertion. The robotic surgery lasted 4.5 h, was uneventful and successful, without recurrence of the ureteropelvic junction obstruction after six months, and with normal development of the patient’s growth and organ function. The use of the robotic system was shown to be safe and feasible; long term follow-up will be conducted subsequently in pediatric surgery.