Cargando…

Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study

The purpose of this study was to assess the accuracy and reliability of tooth width measurements and Bolton Indices delivered by the Clin-Check Pro 6.0 software (Align Technology, San José, CA, USA). Fifty-four plaster casts were selected and measured with a manual calliper by a trained and calibrat...

Descripción completa

Detalles Bibliográficos
Autores principales: Adobes Martin, Milagros, Lipani, Erica, Bernes Martinez, Laura, Alvarado Lorenzo, Alfonso, Aiuto, Riccardo, Garcovich, Daniele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950071/
https://www.ncbi.nlm.nih.gov/pubmed/35329271
http://dx.doi.org/10.3390/ijerph19063581
_version_ 1784675056204382208
author Adobes Martin, Milagros
Lipani, Erica
Bernes Martinez, Laura
Alvarado Lorenzo, Alfonso
Aiuto, Riccardo
Garcovich, Daniele
author_facet Adobes Martin, Milagros
Lipani, Erica
Bernes Martinez, Laura
Alvarado Lorenzo, Alfonso
Aiuto, Riccardo
Garcovich, Daniele
author_sort Adobes Martin, Milagros
collection PubMed
description The purpose of this study was to assess the accuracy and reliability of tooth width measurements and Bolton Indices delivered by the Clin-Check Pro 6.0 software (Align Technology, San José, CA, USA). Fifty-four plaster casts were selected and measured with a manual calliper by a trained and calibrated observer. The data gathered were compared with those delivered by the software on the corresponding fifty-four virtual casts. The method reliability of the software was assessed by comparing the measurements performed by the software on 201 pairs of clin-checks corresponding to two consecutive treatment phases. Accuracy and reliability were statistically assessed using a mixed model. The software tends to provide larger widths compared with the manual method. Statistically significant differences were found in 23 teeth. At a global level, the mean difference between the methods was −0.19 mm, with a Dahlberg error of 0.24 mm and an intraclass correlation coefficient of 0.98. The Bolton Indices delivered by the two methods had a moderate correlation (ICC = 0.59; 0.69). The within method reliability of the software was extremely high. Tooth width measurements delivered by the software, despite the positive bias, can be considered accurate and clinically acceptable for all teeth except molars. The Bolton Indices made available by the software are not accurate and clinically acceptable, especially in the case of mandibular excess.
format Online
Article
Text
id pubmed-8950071
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89500712022-03-26 Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study Adobes Martin, Milagros Lipani, Erica Bernes Martinez, Laura Alvarado Lorenzo, Alfonso Aiuto, Riccardo Garcovich, Daniele Int J Environ Res Public Health Article The purpose of this study was to assess the accuracy and reliability of tooth width measurements and Bolton Indices delivered by the Clin-Check Pro 6.0 software (Align Technology, San José, CA, USA). Fifty-four plaster casts were selected and measured with a manual calliper by a trained and calibrated observer. The data gathered were compared with those delivered by the software on the corresponding fifty-four virtual casts. The method reliability of the software was assessed by comparing the measurements performed by the software on 201 pairs of clin-checks corresponding to two consecutive treatment phases. Accuracy and reliability were statistically assessed using a mixed model. The software tends to provide larger widths compared with the manual method. Statistically significant differences were found in 23 teeth. At a global level, the mean difference between the methods was −0.19 mm, with a Dahlberg error of 0.24 mm and an intraclass correlation coefficient of 0.98. The Bolton Indices delivered by the two methods had a moderate correlation (ICC = 0.59; 0.69). The within method reliability of the software was extremely high. Tooth width measurements delivered by the software, despite the positive bias, can be considered accurate and clinically acceptable for all teeth except molars. The Bolton Indices made available by the software are not accurate and clinically acceptable, especially in the case of mandibular excess. MDPI 2022-03-17 /pmc/articles/PMC8950071/ /pubmed/35329271 http://dx.doi.org/10.3390/ijerph19063581 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Adobes Martin, Milagros
Lipani, Erica
Bernes Martinez, Laura
Alvarado Lorenzo, Alfonso
Aiuto, Riccardo
Garcovich, Daniele
Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
title Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
title_full Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
title_fullStr Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
title_full_unstemmed Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
title_short Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
title_sort reliability of tooth width measurements delivered by the clin-check pro 6.0 software on digital casts: a cross-sectional study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950071/
https://www.ncbi.nlm.nih.gov/pubmed/35329271
http://dx.doi.org/10.3390/ijerph19063581
work_keys_str_mv AT adobesmartinmilagros reliabilityoftoothwidthmeasurementsdeliveredbytheclincheckpro60softwareondigitalcastsacrosssectionalstudy
AT lipanierica reliabilityoftoothwidthmeasurementsdeliveredbytheclincheckpro60softwareondigitalcastsacrosssectionalstudy
AT bernesmartinezlaura reliabilityoftoothwidthmeasurementsdeliveredbytheclincheckpro60softwareondigitalcastsacrosssectionalstudy
AT alvaradolorenzoalfonso reliabilityoftoothwidthmeasurementsdeliveredbytheclincheckpro60softwareondigitalcastsacrosssectionalstudy
AT aiutoriccardo reliabilityoftoothwidthmeasurementsdeliveredbytheclincheckpro60softwareondigitalcastsacrosssectionalstudy
AT garcovichdaniele reliabilityoftoothwidthmeasurementsdeliveredbytheclincheckpro60softwareondigitalcastsacrosssectionalstudy