Cargando…
Osseointegration at Implants Installed in Composite Bone: A Randomized Clinical Trial on Sinus Floor Elevation
Osseointegration of implants installed in conjunction with sinus floor elevation might be affected by the presence of residual graft. The implant surface characteristics and the protection of the access window using a collagen membrane might influence the osseointegration. To evaluate these factors,...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950152/ https://www.ncbi.nlm.nih.gov/pubmed/35323222 http://dx.doi.org/10.3390/jfb13010022 |
_version_ | 1784675072722599936 |
---|---|
author | Kotsu, Mitsuo Apaza Alccayhuaman, Karol Alí Ferri, Mauro Iezzi, Giovanna Piattelli, Adriano Fortich Mesa, Natalia Botticelli, Daniele |
author_facet | Kotsu, Mitsuo Apaza Alccayhuaman, Karol Alí Ferri, Mauro Iezzi, Giovanna Piattelli, Adriano Fortich Mesa, Natalia Botticelli, Daniele |
author_sort | Kotsu, Mitsuo |
collection | PubMed |
description | Osseointegration of implants installed in conjunction with sinus floor elevation might be affected by the presence of residual graft. The implant surface characteristics and the protection of the access window using a collagen membrane might influence the osseointegration. To evaluate these factors, sinus floor elevation was performed in patients using a natural bovine bone grafting material. The access windows were either covered with a collagen membrane made of porcine corium (Mb group) or left uncovered (No-Mb group) and, after six months, two mini-implants with either a moderate rough or turned surfaces were installed. After 3 months, biopsies containing the mini-implants were retrieved, processed histologically, and analyzed. Twenty patients, ten in each group, were included in the study. The two mini-implants were retrieved from fourteen patients, six belonging to the Mb group, and eight to the No-Mb group. No statistically significant differences were found in osseointegration between groups. However, statistically significant differences were found between the two surfaces. It was concluded that implants with a moderately rough surface installed in a composite bone presented much higher osseointegration compared to those with a turned surface. The present study failed to show an effect of the use of a collagen membrane on the access window. |
format | Online Article Text |
id | pubmed-8950152 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89501522022-03-26 Osseointegration at Implants Installed in Composite Bone: A Randomized Clinical Trial on Sinus Floor Elevation Kotsu, Mitsuo Apaza Alccayhuaman, Karol Alí Ferri, Mauro Iezzi, Giovanna Piattelli, Adriano Fortich Mesa, Natalia Botticelli, Daniele J Funct Biomater Article Osseointegration of implants installed in conjunction with sinus floor elevation might be affected by the presence of residual graft. The implant surface characteristics and the protection of the access window using a collagen membrane might influence the osseointegration. To evaluate these factors, sinus floor elevation was performed in patients using a natural bovine bone grafting material. The access windows were either covered with a collagen membrane made of porcine corium (Mb group) or left uncovered (No-Mb group) and, after six months, two mini-implants with either a moderate rough or turned surfaces were installed. After 3 months, biopsies containing the mini-implants were retrieved, processed histologically, and analyzed. Twenty patients, ten in each group, were included in the study. The two mini-implants were retrieved from fourteen patients, six belonging to the Mb group, and eight to the No-Mb group. No statistically significant differences were found in osseointegration between groups. However, statistically significant differences were found between the two surfaces. It was concluded that implants with a moderately rough surface installed in a composite bone presented much higher osseointegration compared to those with a turned surface. The present study failed to show an effect of the use of a collagen membrane on the access window. MDPI 2022-02-28 /pmc/articles/PMC8950152/ /pubmed/35323222 http://dx.doi.org/10.3390/jfb13010022 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kotsu, Mitsuo Apaza Alccayhuaman, Karol Alí Ferri, Mauro Iezzi, Giovanna Piattelli, Adriano Fortich Mesa, Natalia Botticelli, Daniele Osseointegration at Implants Installed in Composite Bone: A Randomized Clinical Trial on Sinus Floor Elevation |
title | Osseointegration at Implants Installed in Composite Bone: A Randomized Clinical Trial on Sinus Floor Elevation |
title_full | Osseointegration at Implants Installed in Composite Bone: A Randomized Clinical Trial on Sinus Floor Elevation |
title_fullStr | Osseointegration at Implants Installed in Composite Bone: A Randomized Clinical Trial on Sinus Floor Elevation |
title_full_unstemmed | Osseointegration at Implants Installed in Composite Bone: A Randomized Clinical Trial on Sinus Floor Elevation |
title_short | Osseointegration at Implants Installed in Composite Bone: A Randomized Clinical Trial on Sinus Floor Elevation |
title_sort | osseointegration at implants installed in composite bone: a randomized clinical trial on sinus floor elevation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950152/ https://www.ncbi.nlm.nih.gov/pubmed/35323222 http://dx.doi.org/10.3390/jfb13010022 |
work_keys_str_mv | AT kotsumitsuo osseointegrationatimplantsinstalledincompositebonearandomizedclinicaltrialonsinusfloorelevation AT apazaalccayhuamankarolali osseointegrationatimplantsinstalledincompositebonearandomizedclinicaltrialonsinusfloorelevation AT ferrimauro osseointegrationatimplantsinstalledincompositebonearandomizedclinicaltrialonsinusfloorelevation AT iezzigiovanna osseointegrationatimplantsinstalledincompositebonearandomizedclinicaltrialonsinusfloorelevation AT piattelliadriano osseointegrationatimplantsinstalledincompositebonearandomizedclinicaltrialonsinusfloorelevation AT fortichmesanatalia osseointegrationatimplantsinstalledincompositebonearandomizedclinicaltrialonsinusfloorelevation AT botticellidaniele osseointegrationatimplantsinstalledincompositebonearandomizedclinicaltrialonsinusfloorelevation |