Cargando…

Impact of DC Transient Disturbances on Harmonic Performance of Voltage Transformers for AC Railway Applications

This paper analyzes the impact of typical DC transient events occurring in railway grids on the frequency performance of instrument transformers (ITs) installed onboard trains and in AC substations for power quality (PQ) applications. PQ monitoring in railway systems is an issue of great interest be...

Descripción completa

Detalles Bibliográficos
Autores principales: Letizia, Palma Sara, Signorino, Davide, Crotti, Gabriella
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950315/
https://www.ncbi.nlm.nih.gov/pubmed/35336441
http://dx.doi.org/10.3390/s22062270
_version_ 1784675111618478080
author Letizia, Palma Sara
Signorino, Davide
Crotti, Gabriella
author_facet Letizia, Palma Sara
Signorino, Davide
Crotti, Gabriella
author_sort Letizia, Palma Sara
collection PubMed
description This paper analyzes the impact of typical DC transient events occurring in railway grids on the frequency performance of instrument transformers (ITs) installed onboard trains and in AC substations for power quality (PQ) applications. PQ monitoring in railway systems is an issue of great interest because it plays a key role in the improvement of energy efficiency. The measurement chain for the PQ measurements, at 15 kV at 16.7 Hz and 25 kV at 50/60 Hz, commonly includes ITs to scale the voltage to levels fitting the input of the measurement units. Nevertheless, the behavior of ITs in the presence of PQ phenomena represents an open issue from a normative point of view, even for those installed in conventional AC power supply systems. In this context, the paper presents a possible definition of DC transient disturbances test waveforms, a measurement procedure, and a setup to assess the impact of these disturbances on the harmonic performances of ITs for railway systems. Preliminary experimental tests carried out on two commercial ITs under wide ranges of variation for the amplitude and the time duration of DC disturbances show that, in some cases, the error introduced in harmonic measurements can exceed 100%.
format Online
Article
Text
id pubmed-8950315
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89503152022-03-26 Impact of DC Transient Disturbances on Harmonic Performance of Voltage Transformers for AC Railway Applications Letizia, Palma Sara Signorino, Davide Crotti, Gabriella Sensors (Basel) Article This paper analyzes the impact of typical DC transient events occurring in railway grids on the frequency performance of instrument transformers (ITs) installed onboard trains and in AC substations for power quality (PQ) applications. PQ monitoring in railway systems is an issue of great interest because it plays a key role in the improvement of energy efficiency. The measurement chain for the PQ measurements, at 15 kV at 16.7 Hz and 25 kV at 50/60 Hz, commonly includes ITs to scale the voltage to levels fitting the input of the measurement units. Nevertheless, the behavior of ITs in the presence of PQ phenomena represents an open issue from a normative point of view, even for those installed in conventional AC power supply systems. In this context, the paper presents a possible definition of DC transient disturbances test waveforms, a measurement procedure, and a setup to assess the impact of these disturbances on the harmonic performances of ITs for railway systems. Preliminary experimental tests carried out on two commercial ITs under wide ranges of variation for the amplitude and the time duration of DC disturbances show that, in some cases, the error introduced in harmonic measurements can exceed 100%. MDPI 2022-03-15 /pmc/articles/PMC8950315/ /pubmed/35336441 http://dx.doi.org/10.3390/s22062270 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Letizia, Palma Sara
Signorino, Davide
Crotti, Gabriella
Impact of DC Transient Disturbances on Harmonic Performance of Voltage Transformers for AC Railway Applications
title Impact of DC Transient Disturbances on Harmonic Performance of Voltage Transformers for AC Railway Applications
title_full Impact of DC Transient Disturbances on Harmonic Performance of Voltage Transformers for AC Railway Applications
title_fullStr Impact of DC Transient Disturbances on Harmonic Performance of Voltage Transformers for AC Railway Applications
title_full_unstemmed Impact of DC Transient Disturbances on Harmonic Performance of Voltage Transformers for AC Railway Applications
title_short Impact of DC Transient Disturbances on Harmonic Performance of Voltage Transformers for AC Railway Applications
title_sort impact of dc transient disturbances on harmonic performance of voltage transformers for ac railway applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950315/
https://www.ncbi.nlm.nih.gov/pubmed/35336441
http://dx.doi.org/10.3390/s22062270
work_keys_str_mv AT letiziapalmasara impactofdctransientdisturbancesonharmonicperformanceofvoltagetransformersforacrailwayapplications
AT signorinodavide impactofdctransientdisturbancesonharmonicperformanceofvoltagetransformersforacrailwayapplications
AT crottigabriella impactofdctransientdisturbancesonharmonicperformanceofvoltagetransformersforacrailwayapplications