Cargando…
A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate
Collecting sweat and monitoring its rate is important for determining body condition and further sweat analyses, as this provides vital information about physiologic status and fitness level and could become an alternative to invasive blood tests in the future. Presented here is a one-dollar, dispos...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950908/ https://www.ncbi.nlm.nih.gov/pubmed/35334706 http://dx.doi.org/10.3390/mi13030414 |
_version_ | 1784675256117493760 |
---|---|
author | Wang, Hongcheng Xu, Kai Xu, Haihao Huang, Along Fang, Zecong Zhang, Yifan Wang, Ze’en Lu, Kai Wan, Fei Bai, Zihao Wang, Qiao Zhang, Linan Wu, Liqun |
author_facet | Wang, Hongcheng Xu, Kai Xu, Haihao Huang, Along Fang, Zecong Zhang, Yifan Wang, Ze’en Lu, Kai Wan, Fei Bai, Zihao Wang, Qiao Zhang, Linan Wu, Liqun |
author_sort | Wang, Hongcheng |
collection | PubMed |
description | Collecting sweat and monitoring its rate is important for determining body condition and further sweat analyses, as this provides vital information about physiologic status and fitness level and could become an alternative to invasive blood tests in the future. Presented here is a one-dollar, disposable, paper-based microfluidic chip for real-time monitoring of sweat rate. The chip, pasted on any part of the skin surface, consists of a skin adhesive layer, sweat-proof layer, sweat-sensing layer, and scale layer with a disk-shape from bottom to top. The sweat-sensing layer has an impressed wax micro-channel containing pre-added chromogenic agent to show displacement by sweat, and the sweat volume can be read directly by scale lines without any electronic elements. The diameter and thickness of the complete chip are 25 mm and 0.3 mm, respectively, permitting good flexibility and compactness with the skin surface. Tests of sweat flow rate monitoring on the left forearm, forehead, and nape of the neck of volunteers doing running exercise were conducted. Average sweat rate on left forearm (1156 g·m(−2)·h(−1)) was much lower than that on the forehead (1710 g·m(−2)·h(−1)) and greater than that on the nape of the neck (998 g·m(−2)·h(−1)), in good agreement with rates measured using existing common commercial sweat collectors. The chip, as a very low-cost and convenient wearable device, has wide application prospects in real-time monitoring of sweat loss by body builders, athletes, firefighters, etc., or for further sweat analyses. |
format | Online Article Text |
id | pubmed-8950908 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89509082022-03-26 A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate Wang, Hongcheng Xu, Kai Xu, Haihao Huang, Along Fang, Zecong Zhang, Yifan Wang, Ze’en Lu, Kai Wan, Fei Bai, Zihao Wang, Qiao Zhang, Linan Wu, Liqun Micromachines (Basel) Article Collecting sweat and monitoring its rate is important for determining body condition and further sweat analyses, as this provides vital information about physiologic status and fitness level and could become an alternative to invasive blood tests in the future. Presented here is a one-dollar, disposable, paper-based microfluidic chip for real-time monitoring of sweat rate. The chip, pasted on any part of the skin surface, consists of a skin adhesive layer, sweat-proof layer, sweat-sensing layer, and scale layer with a disk-shape from bottom to top. The sweat-sensing layer has an impressed wax micro-channel containing pre-added chromogenic agent to show displacement by sweat, and the sweat volume can be read directly by scale lines without any electronic elements. The diameter and thickness of the complete chip are 25 mm and 0.3 mm, respectively, permitting good flexibility and compactness with the skin surface. Tests of sweat flow rate monitoring on the left forearm, forehead, and nape of the neck of volunteers doing running exercise were conducted. Average sweat rate on left forearm (1156 g·m(−2)·h(−1)) was much lower than that on the forehead (1710 g·m(−2)·h(−1)) and greater than that on the nape of the neck (998 g·m(−2)·h(−1)), in good agreement with rates measured using existing common commercial sweat collectors. The chip, as a very low-cost and convenient wearable device, has wide application prospects in real-time monitoring of sweat loss by body builders, athletes, firefighters, etc., or for further sweat analyses. MDPI 2022-03-06 /pmc/articles/PMC8950908/ /pubmed/35334706 http://dx.doi.org/10.3390/mi13030414 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Hongcheng Xu, Kai Xu, Haihao Huang, Along Fang, Zecong Zhang, Yifan Wang, Ze’en Lu, Kai Wan, Fei Bai, Zihao Wang, Qiao Zhang, Linan Wu, Liqun A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate |
title | A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate |
title_full | A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate |
title_fullStr | A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate |
title_full_unstemmed | A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate |
title_short | A One-Dollar, Disposable, Paper-Based Microfluidic Chip for Real-Time Monitoring of Sweat Rate |
title_sort | one-dollar, disposable, paper-based microfluidic chip for real-time monitoring of sweat rate |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950908/ https://www.ncbi.nlm.nih.gov/pubmed/35334706 http://dx.doi.org/10.3390/mi13030414 |
work_keys_str_mv | AT wanghongcheng aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT xukai aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT xuhaihao aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT huangalong aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT fangzecong aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT zhangyifan aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wangzeen aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT lukai aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wanfei aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT baizihao aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wangqiao aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT zhanglinan aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wuliqun aonedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wanghongcheng onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT xukai onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT xuhaihao onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT huangalong onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT fangzecong onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT zhangyifan onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wangzeen onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT lukai onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wanfei onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT baizihao onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wangqiao onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT zhanglinan onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate AT wuliqun onedollardisposablepaperbasedmicrofluidicchipforrealtimemonitoringofsweatrate |