Cargando…
Walk-IT: An Open-Source Modular Low-Cost Smart Rollator
Rollators are widely used in clinical rehabilitation for gait assessment, but gait analysis usually requires a great deal of expertise and focus from medical staff. Smart rollators can capture gait parameters autonomously while avoiding complex setups. However, commercial smart rollators, as closed...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950926/ https://www.ncbi.nlm.nih.gov/pubmed/35336255 http://dx.doi.org/10.3390/s22062086 |
_version_ | 1784675260474327040 |
---|---|
author | Fernandez-Carmona, Manuel Ballesteros, Joaquin Díaz-Boladeras, Marta Parra-Llanas, Xavier Urdiales, Cristina Gómez-de-Gabriel, Jesús Manuel |
author_facet | Fernandez-Carmona, Manuel Ballesteros, Joaquin Díaz-Boladeras, Marta Parra-Llanas, Xavier Urdiales, Cristina Gómez-de-Gabriel, Jesús Manuel |
author_sort | Fernandez-Carmona, Manuel |
collection | PubMed |
description | Rollators are widely used in clinical rehabilitation for gait assessment, but gait analysis usually requires a great deal of expertise and focus from medical staff. Smart rollators can capture gait parameters autonomously while avoiding complex setups. However, commercial smart rollators, as closed systems, can not be modified; plus, they are often expensive and not widely available. This work presents a low cost open-source modular rollator for monitorization of gait parameters and support. The whole system is based on commercial components and its software architecture runs over ROS2 to allow further customization and expansion. This paper describes the overall software and hardware architecture and, as an example of extended capabilities, modules for monitoring dynamic partial weight bearing and for estimation of spatiotemporal gait parameters of clinical interest. All presented tests are coherent from a clinical point of view and consistent with input data. |
format | Online Article Text |
id | pubmed-8950926 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89509262022-03-26 Walk-IT: An Open-Source Modular Low-Cost Smart Rollator Fernandez-Carmona, Manuel Ballesteros, Joaquin Díaz-Boladeras, Marta Parra-Llanas, Xavier Urdiales, Cristina Gómez-de-Gabriel, Jesús Manuel Sensors (Basel) Article Rollators are widely used in clinical rehabilitation for gait assessment, but gait analysis usually requires a great deal of expertise and focus from medical staff. Smart rollators can capture gait parameters autonomously while avoiding complex setups. However, commercial smart rollators, as closed systems, can not be modified; plus, they are often expensive and not widely available. This work presents a low cost open-source modular rollator for monitorization of gait parameters and support. The whole system is based on commercial components and its software architecture runs over ROS2 to allow further customization and expansion. This paper describes the overall software and hardware architecture and, as an example of extended capabilities, modules for monitoring dynamic partial weight bearing and for estimation of spatiotemporal gait parameters of clinical interest. All presented tests are coherent from a clinical point of view and consistent with input data. MDPI 2022-03-08 /pmc/articles/PMC8950926/ /pubmed/35336255 http://dx.doi.org/10.3390/s22062086 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Fernandez-Carmona, Manuel Ballesteros, Joaquin Díaz-Boladeras, Marta Parra-Llanas, Xavier Urdiales, Cristina Gómez-de-Gabriel, Jesús Manuel Walk-IT: An Open-Source Modular Low-Cost Smart Rollator |
title | Walk-IT: An Open-Source Modular Low-Cost Smart Rollator |
title_full | Walk-IT: An Open-Source Modular Low-Cost Smart Rollator |
title_fullStr | Walk-IT: An Open-Source Modular Low-Cost Smart Rollator |
title_full_unstemmed | Walk-IT: An Open-Source Modular Low-Cost Smart Rollator |
title_short | Walk-IT: An Open-Source Modular Low-Cost Smart Rollator |
title_sort | walk-it: an open-source modular low-cost smart rollator |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8950926/ https://www.ncbi.nlm.nih.gov/pubmed/35336255 http://dx.doi.org/10.3390/s22062086 |
work_keys_str_mv | AT fernandezcarmonamanuel walkitanopensourcemodularlowcostsmartrollator AT ballesterosjoaquin walkitanopensourcemodularlowcostsmartrollator AT diazboladerasmarta walkitanopensourcemodularlowcostsmartrollator AT parrallanasxavier walkitanopensourcemodularlowcostsmartrollator AT urdialescristina walkitanopensourcemodularlowcostsmartrollator AT gomezdegabrieljesusmanuel walkitanopensourcemodularlowcostsmartrollator |