Cargando…

Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback

Based on the nonlinear relationship between heart rate and stroke volume, a flow model of left ventricular circulation was improved, and a variable-speed blood-pump control strategy based on heart-rate feedback was proposed. The control strategy was implemented on a system combining the rotary blood...

Descripción completa

Detalles Bibliográficos
Autores principales: Jing, Teng, Xin, Tianye, Wang, Fangqun, Zhang, Zhihao, Zhou, Ling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8951086/
https://www.ncbi.nlm.nih.gov/pubmed/35334650
http://dx.doi.org/10.3390/mi13030358
_version_ 1784675299090235392
author Jing, Teng
Xin, Tianye
Wang, Fangqun
Zhang, Zhihao
Zhou, Ling
author_facet Jing, Teng
Xin, Tianye
Wang, Fangqun
Zhang, Zhihao
Zhou, Ling
author_sort Jing, Teng
collection PubMed
description Based on the nonlinear relationship between heart rate and stroke volume, a flow model of left ventricular circulation was improved, and a variable-speed blood-pump control strategy based on heart-rate feedback was proposed. The control strategy was implemented on a system combining the rotary blood pump and blood circulation models of heart failure. The aortic flow of a healthy heart at different heart rates was the desired control goal. Changes in heart rate were monitored and pump speed was adjusted so that the output flow and aortic pressure of the system would match a normal heart in real time to achieve the best auxiliary state. After simulation with MATLAB, the cardiac output satisfied the ideal perfusion requirements at different heart rates, and aortic pressure demonstrated lifting and had good pulsatile performance when a variable-speed blood pump was used. The coupled model reflected the relationship between hemodynamic parameters at different heart rates with the use of the variable-speed blood pump, providing a theoretical basis for the blood-pump-assisted treatment of heart failure and the design of physiological control strategies.
format Online
Article
Text
id pubmed-8951086
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89510862022-03-26 Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback Jing, Teng Xin, Tianye Wang, Fangqun Zhang, Zhihao Zhou, Ling Micromachines (Basel) Article Based on the nonlinear relationship between heart rate and stroke volume, a flow model of left ventricular circulation was improved, and a variable-speed blood-pump control strategy based on heart-rate feedback was proposed. The control strategy was implemented on a system combining the rotary blood pump and blood circulation models of heart failure. The aortic flow of a healthy heart at different heart rates was the desired control goal. Changes in heart rate were monitored and pump speed was adjusted so that the output flow and aortic pressure of the system would match a normal heart in real time to achieve the best auxiliary state. After simulation with MATLAB, the cardiac output satisfied the ideal perfusion requirements at different heart rates, and aortic pressure demonstrated lifting and had good pulsatile performance when a variable-speed blood pump was used. The coupled model reflected the relationship between hemodynamic parameters at different heart rates with the use of the variable-speed blood pump, providing a theoretical basis for the blood-pump-assisted treatment of heart failure and the design of physiological control strategies. MDPI 2022-02-24 /pmc/articles/PMC8951086/ /pubmed/35334650 http://dx.doi.org/10.3390/mi13030358 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jing, Teng
Xin, Tianye
Wang, Fangqun
Zhang, Zhihao
Zhou, Ling
Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback
title Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback
title_full Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback
title_fullStr Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback
title_full_unstemmed Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback
title_short Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback
title_sort control strategy design of a microblood pump based on heart-rate feedback
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8951086/
https://www.ncbi.nlm.nih.gov/pubmed/35334650
http://dx.doi.org/10.3390/mi13030358
work_keys_str_mv AT jingteng controlstrategydesignofamicrobloodpumpbasedonheartratefeedback
AT xintianye controlstrategydesignofamicrobloodpumpbasedonheartratefeedback
AT wangfangqun controlstrategydesignofamicrobloodpumpbasedonheartratefeedback
AT zhangzhihao controlstrategydesignofamicrobloodpumpbasedonheartratefeedback
AT zhouling controlstrategydesignofamicrobloodpumpbasedonheartratefeedback