Cargando…

Experimental Study on Seismic Behavior of PC Walls with Alveolar-Type Horizontal Joint under Pseudo-Static Loading

There are many horizontal joints on precast concrete (PC) wall panel structures, which certainly has a significant impact on the seismic behavior of structures. This paper proposes a novel alveolar-type horizontal joint, which has advantages of convenient and rapid assembly. Six precast concrete wal...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Junfeng, Luo, Xiaoyong, Cheng, Laixiu, Cheng, Qian, Chen, Linsong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8951119/
https://www.ncbi.nlm.nih.gov/pubmed/35329753
http://dx.doi.org/10.3390/ma15062301
_version_ 1784675307229282304
author Cheng, Junfeng
Luo, Xiaoyong
Cheng, Laixiu
Cheng, Qian
Chen, Linsong
author_facet Cheng, Junfeng
Luo, Xiaoyong
Cheng, Laixiu
Cheng, Qian
Chen, Linsong
author_sort Cheng, Junfeng
collection PubMed
description There are many horizontal joints on precast concrete (PC) wall panel structures, which certainly has a significant impact on the seismic behavior of structures. This paper proposes a novel alveolar-type horizontal joint, which has advantages of convenient and rapid assembly. Six precast concrete wall specimens with alveolar-type joints were designed and constructed, and they were weakly connected by spliced rebars anchored into grouted sleeves to meet the requirements of structural performance. The pseudo-static loading tests on these specimens were conducted to investigate the effects of influencing factors, such as the axial compression ratio, the thickness of wall (interface contact area), and the addition of a vertical grouted sleeve connection at the horizontal joint, on the seismic performance of PC walls. Analyses and comparisons were conducted in terms of the cracking propagation pattern, failure modes, force–displacement hysteretic curves, skeleton curves, bearing capacity, ductility factors, and energy dissipation of PC walls. It was concluded that the axial compression ratio and adding grouted sleeve connection had a significant influence on the cracking mode of PC walls, whereas the impact of the wall thickness was slight. The shear capacity and energy dissipation capacity of specimen dramatically enhanced by increasing the axial compression ratio or adding grouted sleeve connection. The PC wall exhibits good ductility after adding the vertical grouted sleeve connection at a horizontal joint. However, the ductility factor increases firstly and then decreases in the enhancement of the axial compression ratio. The reduction in wall thickness has remarkable impacts on the shear strength and energy dissipation capacity of specimens, but the influences on ductility were not significant. The prediction method for calculating the shear capacity of PC walls with alveolar-type horizontal joints was proposed based on the experimental data, and these calculated results are in good agreement with the experimental results.
format Online
Article
Text
id pubmed-8951119
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89511192022-03-26 Experimental Study on Seismic Behavior of PC Walls with Alveolar-Type Horizontal Joint under Pseudo-Static Loading Cheng, Junfeng Luo, Xiaoyong Cheng, Laixiu Cheng, Qian Chen, Linsong Materials (Basel) Article There are many horizontal joints on precast concrete (PC) wall panel structures, which certainly has a significant impact on the seismic behavior of structures. This paper proposes a novel alveolar-type horizontal joint, which has advantages of convenient and rapid assembly. Six precast concrete wall specimens with alveolar-type joints were designed and constructed, and they were weakly connected by spliced rebars anchored into grouted sleeves to meet the requirements of structural performance. The pseudo-static loading tests on these specimens were conducted to investigate the effects of influencing factors, such as the axial compression ratio, the thickness of wall (interface contact area), and the addition of a vertical grouted sleeve connection at the horizontal joint, on the seismic performance of PC walls. Analyses and comparisons were conducted in terms of the cracking propagation pattern, failure modes, force–displacement hysteretic curves, skeleton curves, bearing capacity, ductility factors, and energy dissipation of PC walls. It was concluded that the axial compression ratio and adding grouted sleeve connection had a significant influence on the cracking mode of PC walls, whereas the impact of the wall thickness was slight. The shear capacity and energy dissipation capacity of specimen dramatically enhanced by increasing the axial compression ratio or adding grouted sleeve connection. The PC wall exhibits good ductility after adding the vertical grouted sleeve connection at a horizontal joint. However, the ductility factor increases firstly and then decreases in the enhancement of the axial compression ratio. The reduction in wall thickness has remarkable impacts on the shear strength and energy dissipation capacity of specimens, but the influences on ductility were not significant. The prediction method for calculating the shear capacity of PC walls with alveolar-type horizontal joints was proposed based on the experimental data, and these calculated results are in good agreement with the experimental results. MDPI 2022-03-20 /pmc/articles/PMC8951119/ /pubmed/35329753 http://dx.doi.org/10.3390/ma15062301 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cheng, Junfeng
Luo, Xiaoyong
Cheng, Laixiu
Cheng, Qian
Chen, Linsong
Experimental Study on Seismic Behavior of PC Walls with Alveolar-Type Horizontal Joint under Pseudo-Static Loading
title Experimental Study on Seismic Behavior of PC Walls with Alveolar-Type Horizontal Joint under Pseudo-Static Loading
title_full Experimental Study on Seismic Behavior of PC Walls with Alveolar-Type Horizontal Joint under Pseudo-Static Loading
title_fullStr Experimental Study on Seismic Behavior of PC Walls with Alveolar-Type Horizontal Joint under Pseudo-Static Loading
title_full_unstemmed Experimental Study on Seismic Behavior of PC Walls with Alveolar-Type Horizontal Joint under Pseudo-Static Loading
title_short Experimental Study on Seismic Behavior of PC Walls with Alveolar-Type Horizontal Joint under Pseudo-Static Loading
title_sort experimental study on seismic behavior of pc walls with alveolar-type horizontal joint under pseudo-static loading
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8951119/
https://www.ncbi.nlm.nih.gov/pubmed/35329753
http://dx.doi.org/10.3390/ma15062301
work_keys_str_mv AT chengjunfeng experimentalstudyonseismicbehaviorofpcwallswithalveolartypehorizontaljointunderpseudostaticloading
AT luoxiaoyong experimentalstudyonseismicbehaviorofpcwallswithalveolartypehorizontaljointunderpseudostaticloading
AT chenglaixiu experimentalstudyonseismicbehaviorofpcwallswithalveolartypehorizontaljointunderpseudostaticloading
AT chengqian experimentalstudyonseismicbehaviorofpcwallswithalveolartypehorizontaljointunderpseudostaticloading
AT chenlinsong experimentalstudyonseismicbehaviorofpcwallswithalveolartypehorizontaljointunderpseudostaticloading