Cargando…
Reusability of P3 Facial Filter in a Pandemic Emergency: A 3D Analysis of Filter Microstructure with X-ray Microtomography Images after Dry Heat and UV Sterilization Procedures
Objective: Our goal is to evaluate the effects of heat and ultraviolet (UV) irradiation on P3 facial respirator microstructure. Intervention: P3 facial filters were exposed to dry heat and UV sterilization procedures. Methods: P3 facial filter samples underwent a standardized sterilization process b...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8952298/ https://www.ncbi.nlm.nih.gov/pubmed/35329123 http://dx.doi.org/10.3390/ijerph19063435 |
_version_ | 1784675580464070656 |
---|---|
author | Borro, Luca Raponi, Massimiliano Del Fattore, Andrea Zanini, Franco di Lillo, Francesca Contillo, Adriano Bordonaro, Veronica Di Piazza, Eleonora Tozzi, Alberto E. Secinaro, Aurelio |
author_facet | Borro, Luca Raponi, Massimiliano Del Fattore, Andrea Zanini, Franco di Lillo, Francesca Contillo, Adriano Bordonaro, Veronica Di Piazza, Eleonora Tozzi, Alberto E. Secinaro, Aurelio |
author_sort | Borro, Luca |
collection | PubMed |
description | Objective: Our goal is to evaluate the effects of heat and ultraviolet (UV) irradiation on P3 facial respirator microstructure. Intervention: P3 facial filters were exposed to dry heat and UV sterilization procedures. Methods: P3 facial filter samples underwent a standardized sterilization process based on dry heat and UV irradiation techniques. We analyzed critical parameters of internal microstructure, such as fiber thickness and porosity, before and after sterilization, using 3D data obtained with synchrotron radiation-based X-ray computed microtomography (micro-CT). The analyzed filter has two inner layers called the “finer” and “coarser” layers. The “finer” layer consists of a dense fiber network, while the “coarser” layer has a less compact fiber network. Results: Analysis of 3D images showed no statistically significant differences between the P3 filter of the controls and the dry heat/UV sterilized samples. In particular, averages fiber thickness in the finer layer of the control and the 60° dry heated and UV-irradiated sample groups was almost identical. Average fiber thickness for the coarser layer of the control and the 60° dry heated and UV-irradiated sample groups was very similar, measuring 19.33 µm (±0.47), 18.33 µm (±0.47), and 18.66 µm (±0.47), respectively. There was no substantial difference in maximum fiber thickness in the finer layers and coarser layers. For the control group samples, maximum thickness was on average 11.43 µm (±1.24) in the finer layer and 59.33 µm (±6.79) in the coarser layer. Similarly, the 60° dry heated group samples were thickened 12.2 µm (±0.21) in the finer layer and 57.33 µm (±1.24) in the coarser layer, while for the UV-irradiated group, the mean max thickness was 12.23 µm (±0.90) in the finer layer and 58.00 µm (±6.68) in the coarser layer. Theoretical porosity analysis resulted in 74% and 88% for the finer and coarser layers. The finer layers’ theoretical porosity tended to decrease in dry heat and UV-irradiated samples compared with the respective control samples. Conclusions: Dry heat and UV sterilization processes do not substantially alter the morphometry of the P3 filter samples’ internal microstructure, as studied with micro-CT. The current study suggests that safe P3 filter facepiece reusability is theoretically feasible and should be further investigated. |
format | Online Article Text |
id | pubmed-8952298 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89522982022-03-26 Reusability of P3 Facial Filter in a Pandemic Emergency: A 3D Analysis of Filter Microstructure with X-ray Microtomography Images after Dry Heat and UV Sterilization Procedures Borro, Luca Raponi, Massimiliano Del Fattore, Andrea Zanini, Franco di Lillo, Francesca Contillo, Adriano Bordonaro, Veronica Di Piazza, Eleonora Tozzi, Alberto E. Secinaro, Aurelio Int J Environ Res Public Health Article Objective: Our goal is to evaluate the effects of heat and ultraviolet (UV) irradiation on P3 facial respirator microstructure. Intervention: P3 facial filters were exposed to dry heat and UV sterilization procedures. Methods: P3 facial filter samples underwent a standardized sterilization process based on dry heat and UV irradiation techniques. We analyzed critical parameters of internal microstructure, such as fiber thickness and porosity, before and after sterilization, using 3D data obtained with synchrotron radiation-based X-ray computed microtomography (micro-CT). The analyzed filter has two inner layers called the “finer” and “coarser” layers. The “finer” layer consists of a dense fiber network, while the “coarser” layer has a less compact fiber network. Results: Analysis of 3D images showed no statistically significant differences between the P3 filter of the controls and the dry heat/UV sterilized samples. In particular, averages fiber thickness in the finer layer of the control and the 60° dry heated and UV-irradiated sample groups was almost identical. Average fiber thickness for the coarser layer of the control and the 60° dry heated and UV-irradiated sample groups was very similar, measuring 19.33 µm (±0.47), 18.33 µm (±0.47), and 18.66 µm (±0.47), respectively. There was no substantial difference in maximum fiber thickness in the finer layers and coarser layers. For the control group samples, maximum thickness was on average 11.43 µm (±1.24) in the finer layer and 59.33 µm (±6.79) in the coarser layer. Similarly, the 60° dry heated group samples were thickened 12.2 µm (±0.21) in the finer layer and 57.33 µm (±1.24) in the coarser layer, while for the UV-irradiated group, the mean max thickness was 12.23 µm (±0.90) in the finer layer and 58.00 µm (±6.68) in the coarser layer. Theoretical porosity analysis resulted in 74% and 88% for the finer and coarser layers. The finer layers’ theoretical porosity tended to decrease in dry heat and UV-irradiated samples compared with the respective control samples. Conclusions: Dry heat and UV sterilization processes do not substantially alter the morphometry of the P3 filter samples’ internal microstructure, as studied with micro-CT. The current study suggests that safe P3 filter facepiece reusability is theoretically feasible and should be further investigated. MDPI 2022-03-14 /pmc/articles/PMC8952298/ /pubmed/35329123 http://dx.doi.org/10.3390/ijerph19063435 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Borro, Luca Raponi, Massimiliano Del Fattore, Andrea Zanini, Franco di Lillo, Francesca Contillo, Adriano Bordonaro, Veronica Di Piazza, Eleonora Tozzi, Alberto E. Secinaro, Aurelio Reusability of P3 Facial Filter in a Pandemic Emergency: A 3D Analysis of Filter Microstructure with X-ray Microtomography Images after Dry Heat and UV Sterilization Procedures |
title | Reusability of P3 Facial Filter in a Pandemic Emergency: A 3D Analysis of Filter Microstructure with X-ray Microtomography Images after Dry Heat and UV Sterilization Procedures |
title_full | Reusability of P3 Facial Filter in a Pandemic Emergency: A 3D Analysis of Filter Microstructure with X-ray Microtomography Images after Dry Heat and UV Sterilization Procedures |
title_fullStr | Reusability of P3 Facial Filter in a Pandemic Emergency: A 3D Analysis of Filter Microstructure with X-ray Microtomography Images after Dry Heat and UV Sterilization Procedures |
title_full_unstemmed | Reusability of P3 Facial Filter in a Pandemic Emergency: A 3D Analysis of Filter Microstructure with X-ray Microtomography Images after Dry Heat and UV Sterilization Procedures |
title_short | Reusability of P3 Facial Filter in a Pandemic Emergency: A 3D Analysis of Filter Microstructure with X-ray Microtomography Images after Dry Heat and UV Sterilization Procedures |
title_sort | reusability of p3 facial filter in a pandemic emergency: a 3d analysis of filter microstructure with x-ray microtomography images after dry heat and uv sterilization procedures |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8952298/ https://www.ncbi.nlm.nih.gov/pubmed/35329123 http://dx.doi.org/10.3390/ijerph19063435 |
work_keys_str_mv | AT borroluca reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT raponimassimiliano reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT delfattoreandrea reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT zaninifranco reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT dilillofrancesca reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT contilloadriano reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT bordonaroveronica reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT dipiazzaeleonora reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT tozzialbertoe reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures AT secinaroaurelio reusabilityofp3facialfilterinapandemicemergencya3danalysisoffiltermicrostructurewithxraymicrotomographyimagesafterdryheatanduvsterilizationprocedures |