A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis
In the microchip electrophoresis with capacitively coupled contactless conductivity detection, the stray capacitance of the detector causes high background noise, which seriously affects the sensitivity and stability of the detection system. To reduce the effect, a novel design of planar grounded ca...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8953769/ https://www.ncbi.nlm.nih.gov/pubmed/35334684 http://dx.doi.org/10.3390/mi13030394 |
_version_ | 1784675931415117824 |
---|---|
author | Wang, Jianjiao Liu, Yaping He, Wenhe Chen, Yuanfen You, Hui |
author_facet | Wang, Jianjiao Liu, Yaping He, Wenhe Chen, Yuanfen You, Hui |
author_sort | Wang, Jianjiao |
collection | PubMed |
description | In the microchip electrophoresis with capacitively coupled contactless conductivity detection, the stray capacitance of the detector causes high background noise, which seriously affects the sensitivity and stability of the detection system. To reduce the effect, a novel design of planar grounded capacitively coupled contactless conductivity detector (PG-C4D) based on printed circuit board (PCB) is proposed. The entire circuit plane except the sensing electrodes is covered by the ground electrode, greatly reducing the stray capacitance. The efficacy of the design has been verified by the electrical field simulation and the electrophoresis detection experiments of inorganic ions. The baseline intensity of the PG-C4D was less than 1/6 of that of the traditional C4D. The PG-C4D with the new design also demonstrated a good repeatability of migration time, peak area, and peak height (n = 5, relative standard deviation, RSD ≤ 0.3%, 3%, and 4%, respectively), and good linear coefficients within the range of 0.05–0.75 mM (R(2) ≥ 0.986). The detection sensitivity of K(+), Na(+), and Li(+) reached 0.05, 0.1, and 0.1 mM respectively. Those results prove that the new design is an effective and economical approach which can improve sensitivity and repeatability of a PCB based PG-C4D, which indicate a great application potential in agricultural and environmental monitoring. |
format | Online Article Text |
id | pubmed-8953769 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89537692022-03-26 A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis Wang, Jianjiao Liu, Yaping He, Wenhe Chen, Yuanfen You, Hui Micromachines (Basel) Article In the microchip electrophoresis with capacitively coupled contactless conductivity detection, the stray capacitance of the detector causes high background noise, which seriously affects the sensitivity and stability of the detection system. To reduce the effect, a novel design of planar grounded capacitively coupled contactless conductivity detector (PG-C4D) based on printed circuit board (PCB) is proposed. The entire circuit plane except the sensing electrodes is covered by the ground electrode, greatly reducing the stray capacitance. The efficacy of the design has been verified by the electrical field simulation and the electrophoresis detection experiments of inorganic ions. The baseline intensity of the PG-C4D was less than 1/6 of that of the traditional C4D. The PG-C4D with the new design also demonstrated a good repeatability of migration time, peak area, and peak height (n = 5, relative standard deviation, RSD ≤ 0.3%, 3%, and 4%, respectively), and good linear coefficients within the range of 0.05–0.75 mM (R(2) ≥ 0.986). The detection sensitivity of K(+), Na(+), and Li(+) reached 0.05, 0.1, and 0.1 mM respectively. Those results prove that the new design is an effective and economical approach which can improve sensitivity and repeatability of a PCB based PG-C4D, which indicate a great application potential in agricultural and environmental monitoring. MDPI 2022-02-28 /pmc/articles/PMC8953769/ /pubmed/35334684 http://dx.doi.org/10.3390/mi13030394 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Jianjiao Liu, Yaping He, Wenhe Chen, Yuanfen You, Hui A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis |
title | A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis |
title_full | A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis |
title_fullStr | A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis |
title_full_unstemmed | A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis |
title_short | A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis |
title_sort | novel planar grounded capacitively coupled contactless conductivity detector for microchip electrophoresis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8953769/ https://www.ncbi.nlm.nih.gov/pubmed/35334684 http://dx.doi.org/10.3390/mi13030394 |
work_keys_str_mv | AT wangjianjiao anovelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT liuyaping anovelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT hewenhe anovelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT chenyuanfen anovelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT youhui anovelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT wangjianjiao novelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT liuyaping novelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT hewenhe novelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT chenyuanfen novelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis AT youhui novelplanargroundedcapacitivelycoupledcontactlessconductivitydetectorformicrochipelectrophoresis |