The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor
Background: Injectable cardiac monitors (ICMs) are leadless subcutaneous devices for long-term monitoring of arrhythmias. The BIOTRONIK BIOMONITOR III is a novel ICM with a miniaturized profile, long sensing vector, and simplified implantation technique. Methods: R-wave amplitude was recorded immedi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8954265/ https://www.ncbi.nlm.nih.gov/pubmed/35329960 http://dx.doi.org/10.3390/jcm11061634 |
_version_ | 1784676052068466688 |
---|---|
author | Reinsch, Nico Füting, Anna Höwel, Dennis Neven, Kars |
author_facet | Reinsch, Nico Füting, Anna Höwel, Dennis Neven, Kars |
author_sort | Reinsch, Nico |
collection | PubMed |
description | Background: Injectable cardiac monitors (ICMs) are leadless subcutaneous devices for long-term monitoring of arrhythmias. The BIOTRONIK BIOMONITOR III is a novel ICM with a miniaturized profile, long sensing vector, and simplified implantation technique. Methods: R-wave amplitude was recorded immediately after implantation, the day after implantation, and after 3 months. Follow-up was scheduled after 3 months or after an event. All data from the ICM were retrieved. The anatomical position of the ICM was determined post-implantation and after 3 months. A patient questionnaire was conducted after 3 months. Results: In 36 patients (mean age 67 ± 13 years; 40% male) an ICM was inserted. Six patients were not included in the final analysis. The median time from skin cut to wound closure was 6 [IQR 5–7] minutes. Mean R-wave amplitude increased over time (0.73 ± 32 mV vs. 0.78 ± 0.38 mV vs. 0.81 ± 0.39 mV; p = ns). Three months after implantation, the ICM was in an anatomically stable position. In 14 (47%) patients, true episodes were detected. False arrhythmia alerts were detected in 13 (43%) patients. The total number of false detections was low, and the patient satisfaction rate was high. Conclusion: Implantation of the novel BIOMONITOR III is fast and uncomplicated; its sensing characteristics are excellent and improve over time, and patient satisfaction is high. |
format | Online Article Text |
id | pubmed-8954265 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89542652022-03-26 The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor Reinsch, Nico Füting, Anna Höwel, Dennis Neven, Kars J Clin Med Article Background: Injectable cardiac monitors (ICMs) are leadless subcutaneous devices for long-term monitoring of arrhythmias. The BIOTRONIK BIOMONITOR III is a novel ICM with a miniaturized profile, long sensing vector, and simplified implantation technique. Methods: R-wave amplitude was recorded immediately after implantation, the day after implantation, and after 3 months. Follow-up was scheduled after 3 months or after an event. All data from the ICM were retrieved. The anatomical position of the ICM was determined post-implantation and after 3 months. A patient questionnaire was conducted after 3 months. Results: In 36 patients (mean age 67 ± 13 years; 40% male) an ICM was inserted. Six patients were not included in the final analysis. The median time from skin cut to wound closure was 6 [IQR 5–7] minutes. Mean R-wave amplitude increased over time (0.73 ± 32 mV vs. 0.78 ± 0.38 mV vs. 0.81 ± 0.39 mV; p = ns). Three months after implantation, the ICM was in an anatomically stable position. In 14 (47%) patients, true episodes were detected. False arrhythmia alerts were detected in 13 (43%) patients. The total number of false detections was low, and the patient satisfaction rate was high. Conclusion: Implantation of the novel BIOMONITOR III is fast and uncomplicated; its sensing characteristics are excellent and improve over time, and patient satisfaction is high. MDPI 2022-03-16 /pmc/articles/PMC8954265/ /pubmed/35329960 http://dx.doi.org/10.3390/jcm11061634 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Reinsch, Nico Füting, Anna Höwel, Dennis Neven, Kars The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor |
title | The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor |
title_full | The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor |
title_fullStr | The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor |
title_full_unstemmed | The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor |
title_short | The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor |
title_sort | biomonitor iii injectable cardiac monitor: clinical experience with a novel injectable cardiac monitor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8954265/ https://www.ncbi.nlm.nih.gov/pubmed/35329960 http://dx.doi.org/10.3390/jcm11061634 |
work_keys_str_mv | AT reinschnico thebiomonitoriiiinjectablecardiacmonitorclinicalexperiencewithanovelinjectablecardiacmonitor AT futinganna thebiomonitoriiiinjectablecardiacmonitorclinicalexperiencewithanovelinjectablecardiacmonitor AT howeldennis thebiomonitoriiiinjectablecardiacmonitorclinicalexperiencewithanovelinjectablecardiacmonitor AT nevenkars thebiomonitoriiiinjectablecardiacmonitorclinicalexperiencewithanovelinjectablecardiacmonitor AT reinschnico biomonitoriiiinjectablecardiacmonitorclinicalexperiencewithanovelinjectablecardiacmonitor AT futinganna biomonitoriiiinjectablecardiacmonitorclinicalexperiencewithanovelinjectablecardiacmonitor AT howeldennis biomonitoriiiinjectablecardiacmonitorclinicalexperiencewithanovelinjectablecardiacmonitor AT nevenkars biomonitoriiiinjectablecardiacmonitorclinicalexperiencewithanovelinjectablecardiacmonitor |