Cargando…
The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples
Strychnine (STN) and its major metabolite Strychnine N-Oxide (SNO) were examined electrochemically. Both parent compounds and its major metabolite showed electroactivity on glassy carbon electrodes using CV and DPV techniques. One oxidation peak at 1008 mV was observed for STN with the optimum peak...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8954432/ https://www.ncbi.nlm.nih.gov/pubmed/35335189 http://dx.doi.org/10.3390/molecules27061826 |
_version_ | 1784676091881848832 |
---|---|
author | Qader, Bakhtiyar Hussain, Issam Baron, Mark Estevez-Brito, Rafael Cassella, John Paul Gonzalez-Rodriguez, Jose |
author_facet | Qader, Bakhtiyar Hussain, Issam Baron, Mark Estevez-Brito, Rafael Cassella, John Paul Gonzalez-Rodriguez, Jose |
author_sort | Qader, Bakhtiyar |
collection | PubMed |
description | Strychnine (STN) and its major metabolite Strychnine N-Oxide (SNO) were examined electrochemically. Both parent compounds and its major metabolite showed electroactivity on glassy carbon electrodes using CV and DPV techniques. One oxidation peak at 1008 mV was observed for STN with the optimum peak intensity at pH 7. SNO produced two oxidation peaks, at 617 mV and 797 mV, at pH 5. The peaks demonstrated irreversible behaviour and the irreversibility of the system was confirmed at different scan rates. A calibration curve was produced for both CV and DPV measurements and the sensitivity of the proposed EC method was good compared with previous electrochemical and non-electrochemical methods. The precision of oxidation peak of STN using the STN-MIP method produced a maximum value of 11.5% and 2.32% for inter-day and intraday %RSD, respectively. The average% recovery was around 92%. The electrochemical method has been successfully applied to the determination of STN in spiked plasma and urine samples. For SNO, both anodic peaks of SNO demonstrated irreversible behaviour. A different sweep rate was used for calculating the number of ‘transfer electrons’ in the system; based on this, the mechanism of oxidation reaction was proposed. Calibration curves for both oxidative peaks were produced using DPV measurements. The second anodic peak demonstrated high linearity and precision with %RSD < 1.96%. |
format | Online Article Text |
id | pubmed-8954432 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89544322022-03-26 The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples Qader, Bakhtiyar Hussain, Issam Baron, Mark Estevez-Brito, Rafael Cassella, John Paul Gonzalez-Rodriguez, Jose Molecules Article Strychnine (STN) and its major metabolite Strychnine N-Oxide (SNO) were examined electrochemically. Both parent compounds and its major metabolite showed electroactivity on glassy carbon electrodes using CV and DPV techniques. One oxidation peak at 1008 mV was observed for STN with the optimum peak intensity at pH 7. SNO produced two oxidation peaks, at 617 mV and 797 mV, at pH 5. The peaks demonstrated irreversible behaviour and the irreversibility of the system was confirmed at different scan rates. A calibration curve was produced for both CV and DPV measurements and the sensitivity of the proposed EC method was good compared with previous electrochemical and non-electrochemical methods. The precision of oxidation peak of STN using the STN-MIP method produced a maximum value of 11.5% and 2.32% for inter-day and intraday %RSD, respectively. The average% recovery was around 92%. The electrochemical method has been successfully applied to the determination of STN in spiked plasma and urine samples. For SNO, both anodic peaks of SNO demonstrated irreversible behaviour. A different sweep rate was used for calculating the number of ‘transfer electrons’ in the system; based on this, the mechanism of oxidation reaction was proposed. Calibration curves for both oxidative peaks were produced using DPV measurements. The second anodic peak demonstrated high linearity and precision with %RSD < 1.96%. MDPI 2022-03-11 /pmc/articles/PMC8954432/ /pubmed/35335189 http://dx.doi.org/10.3390/molecules27061826 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Qader, Bakhtiyar Hussain, Issam Baron, Mark Estevez-Brito, Rafael Cassella, John Paul Gonzalez-Rodriguez, Jose The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples |
title | The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples |
title_full | The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples |
title_fullStr | The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples |
title_full_unstemmed | The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples |
title_short | The Production and Evaluation of an Electrochemical Sensors for Strychnine and Its Main Metabolite Strychnine N-Oxide for Their Use in Biological Samples |
title_sort | production and evaluation of an electrochemical sensors for strychnine and its main metabolite strychnine n-oxide for their use in biological samples |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8954432/ https://www.ncbi.nlm.nih.gov/pubmed/35335189 http://dx.doi.org/10.3390/molecules27061826 |
work_keys_str_mv | AT qaderbakhtiyar theproductionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT hussainissam theproductionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT baronmark theproductionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT estevezbritorafael theproductionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT cassellajohnpaul theproductionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT gonzalezrodriguezjose theproductionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT qaderbakhtiyar productionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT hussainissam productionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT baronmark productionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT estevezbritorafael productionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT cassellajohnpaul productionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples AT gonzalezrodriguezjose productionandevaluationofanelectrochemicalsensorsforstrychnineanditsmainmetabolitestrychninenoxidefortheiruseinbiologicalsamples |