Cargando…

Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns

Concrete-filled composite columns are widely used in the construction industry, exploiting the benefits of combining steel and concrete, providing, for instance, high load-bearing capacities and enhanced fire resistance. These solutions are extensively used in high-rise buildings and/or when high fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Craveiro, Hélder D., Rahnavard, Rohola, Henriques, José, Simões, Rui A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8954931/
https://www.ncbi.nlm.nih.gov/pubmed/35329611
http://dx.doi.org/10.3390/ma15062159
_version_ 1784676214705750016
author Craveiro, Hélder D.
Rahnavard, Rohola
Henriques, José
Simões, Rui A.
author_facet Craveiro, Hélder D.
Rahnavard, Rohola
Henriques, José
Simões, Rui A.
author_sort Craveiro, Hélder D.
collection PubMed
description Concrete-filled composite columns are widely used in the construction industry, exploiting the benefits of combining steel and concrete, providing, for instance, high load-bearing capacities and enhanced fire resistance. These solutions are extensively used in high-rise buildings and/or when high fire resistance performance requirements are imposed. In this exploratory research, a new type of concrete-filled composite column is investigated using fire resistance tests. Promoting the use of cold-formed steel products and developing innovative solutions for low-rise buildings with lower passive fire protection requirements led to the solutions presented in this research. Hence, a set of fire-resistance tests were undertaken on concrete-filled closed built-up cold-formed steel columns, where single cold-formed steel shapes are combined and fastened to create a box-shaped cross-section. The experimental results were then compared with the corresponding bare steel solutions to assess, in detail, the observed enhancements. Additionally, the effect of restraint on thermal elongation was assessed.
format Online
Article
Text
id pubmed-8954931
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89549312022-03-26 Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns Craveiro, Hélder D. Rahnavard, Rohola Henriques, José Simões, Rui A. Materials (Basel) Article Concrete-filled composite columns are widely used in the construction industry, exploiting the benefits of combining steel and concrete, providing, for instance, high load-bearing capacities and enhanced fire resistance. These solutions are extensively used in high-rise buildings and/or when high fire resistance performance requirements are imposed. In this exploratory research, a new type of concrete-filled composite column is investigated using fire resistance tests. Promoting the use of cold-formed steel products and developing innovative solutions for low-rise buildings with lower passive fire protection requirements led to the solutions presented in this research. Hence, a set of fire-resistance tests were undertaken on concrete-filled closed built-up cold-formed steel columns, where single cold-formed steel shapes are combined and fastened to create a box-shaped cross-section. The experimental results were then compared with the corresponding bare steel solutions to assess, in detail, the observed enhancements. Additionally, the effect of restraint on thermal elongation was assessed. MDPI 2022-03-15 /pmc/articles/PMC8954931/ /pubmed/35329611 http://dx.doi.org/10.3390/ma15062159 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Craveiro, Hélder D.
Rahnavard, Rohola
Henriques, José
Simões, Rui A.
Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns
title Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns
title_full Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns
title_fullStr Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns
title_full_unstemmed Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns
title_short Structural Fire Performance of Concrete-Filled Built-Up Cold-Formed Steel Columns
title_sort structural fire performance of concrete-filled built-up cold-formed steel columns
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8954931/
https://www.ncbi.nlm.nih.gov/pubmed/35329611
http://dx.doi.org/10.3390/ma15062159
work_keys_str_mv AT craveirohelderd structuralfireperformanceofconcretefilledbuiltupcoldformedsteelcolumns
AT rahnavardrohola structuralfireperformanceofconcretefilledbuiltupcoldformedsteelcolumns
AT henriquesjose structuralfireperformanceofconcretefilledbuiltupcoldformedsteelcolumns
AT simoesruia structuralfireperformanceofconcretefilledbuiltupcoldformedsteelcolumns