Cargando…
The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy
To prove the role of high-tech investigation in monitoring corneal morphological changes in patients with neurotrophic keratopathy (NK) using Keratograph 5M (K5M) and anterior segment OCT (AS-OCT), corneal healing was monitored with Keratograph 5M (Oculus, Wetzlar, Germany) and AS-OCT (DRI, Triton,...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8955972/ https://www.ncbi.nlm.nih.gov/pubmed/35329927 http://dx.doi.org/10.3390/jcm11061602 |
_version_ | 1784676467120013312 |
---|---|
author | Inferrera, Leandro Aragona, Emanuela Wylęgała, Adam Valastro, Antonio Latino, Gianluigi Postorino, Elisa I. Gargano, Romana Orzechowska-Wylęgała, Bogusława Wylęgała, Edward Roszkowska, Anna M. |
author_facet | Inferrera, Leandro Aragona, Emanuela Wylęgała, Adam Valastro, Antonio Latino, Gianluigi Postorino, Elisa I. Gargano, Romana Orzechowska-Wylęgała, Bogusława Wylęgała, Edward Roszkowska, Anna M. |
author_sort | Inferrera, Leandro |
collection | PubMed |
description | To prove the role of high-tech investigation in monitoring corneal morphological changes in patients with neurotrophic keratopathy (NK) using Keratograph 5M (K5M) and anterior segment OCT (AS-OCT), corneal healing was monitored with Keratograph 5M (Oculus, Wetzlar, Germany) and AS-OCT (DRI, Triton, Topcon, Tokyo, Japan) in 13 patients (8F and 5M), aged from 24 to 93 years (67.8 ± 19) with severe NK, who were treated with Cenegermin 0.002% (20 μg/mL) (Oxervate(®), Dompè, Farmaceutici Spa, Milan, Italy). The surface defects were evaluated on Keratograph 5M with ImageJ software and the corneal thickness variations were measured using DRI-Triton OCT software. Instrumental procedures were performed at baseline, and after 4 and 8 weeks of the treatment, respectively. The main outcome measures were reduction of the ulcers’ area and corneal thickness recovery. The mean area of the corneal ulcers was reduced between baseline and 4 weeks examination in all patients, and at 8 weeks all ulcers were completely healed. An increase of the corneal thickness was evidenced between the baseline visit and after the 4- and 8-week follow-up, respectively. Additionally, only in collaborating subjects the In Vivo Confocal Microscopy (IVCM) was performed with HRT Rostock Cornea Module (Heidelberg Eng GmbH) to study the corneal nerves fibres. High-tech diagnostics with K5M, AS-OCT and IVCM proved useful in the assessment of corneal morphology and the healing process in patients with NK and could be extended to assess other corneal pathologies. |
format | Online Article Text |
id | pubmed-8955972 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89559722022-03-26 The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy Inferrera, Leandro Aragona, Emanuela Wylęgała, Adam Valastro, Antonio Latino, Gianluigi Postorino, Elisa I. Gargano, Romana Orzechowska-Wylęgała, Bogusława Wylęgała, Edward Roszkowska, Anna M. J Clin Med Article To prove the role of high-tech investigation in monitoring corneal morphological changes in patients with neurotrophic keratopathy (NK) using Keratograph 5M (K5M) and anterior segment OCT (AS-OCT), corneal healing was monitored with Keratograph 5M (Oculus, Wetzlar, Germany) and AS-OCT (DRI, Triton, Topcon, Tokyo, Japan) in 13 patients (8F and 5M), aged from 24 to 93 years (67.8 ± 19) with severe NK, who were treated with Cenegermin 0.002% (20 μg/mL) (Oxervate(®), Dompè, Farmaceutici Spa, Milan, Italy). The surface defects were evaluated on Keratograph 5M with ImageJ software and the corneal thickness variations were measured using DRI-Triton OCT software. Instrumental procedures were performed at baseline, and after 4 and 8 weeks of the treatment, respectively. The main outcome measures were reduction of the ulcers’ area and corneal thickness recovery. The mean area of the corneal ulcers was reduced between baseline and 4 weeks examination in all patients, and at 8 weeks all ulcers were completely healed. An increase of the corneal thickness was evidenced between the baseline visit and after the 4- and 8-week follow-up, respectively. Additionally, only in collaborating subjects the In Vivo Confocal Microscopy (IVCM) was performed with HRT Rostock Cornea Module (Heidelberg Eng GmbH) to study the corneal nerves fibres. High-tech diagnostics with K5M, AS-OCT and IVCM proved useful in the assessment of corneal morphology and the healing process in patients with NK and could be extended to assess other corneal pathologies. MDPI 2022-03-14 /pmc/articles/PMC8955972/ /pubmed/35329927 http://dx.doi.org/10.3390/jcm11061602 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Inferrera, Leandro Aragona, Emanuela Wylęgała, Adam Valastro, Antonio Latino, Gianluigi Postorino, Elisa I. Gargano, Romana Orzechowska-Wylęgała, Bogusława Wylęgała, Edward Roszkowska, Anna M. The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy |
title | The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy |
title_full | The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy |
title_fullStr | The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy |
title_full_unstemmed | The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy |
title_short | The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy |
title_sort | role of hi-tech devices in assessment of corneal healing in patients with neurotrophic keratopathy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8955972/ https://www.ncbi.nlm.nih.gov/pubmed/35329927 http://dx.doi.org/10.3390/jcm11061602 |
work_keys_str_mv | AT inferreraleandro theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT aragonaemanuela theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT wylegałaadam theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT valastroantonio theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT latinogianluigi theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT postorinoelisai theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT garganoromana theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT orzechowskawylegałabogusława theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT wylegałaedward theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT roszkowskaannam theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT inferreraleandro roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT aragonaemanuela roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT wylegałaadam roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT valastroantonio roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT latinogianluigi roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT postorinoelisai roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT garganoromana roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT orzechowskawylegałabogusława roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT wylegałaedward roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy AT roszkowskaannam roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy |