Cargando…

The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy

To prove the role of high-tech investigation in monitoring corneal morphological changes in patients with neurotrophic keratopathy (NK) using Keratograph 5M (K5M) and anterior segment OCT (AS-OCT), corneal healing was monitored with Keratograph 5M (Oculus, Wetzlar, Germany) and AS-OCT (DRI, Triton,...

Descripción completa

Detalles Bibliográficos
Autores principales: Inferrera, Leandro, Aragona, Emanuela, Wylęgała, Adam, Valastro, Antonio, Latino, Gianluigi, Postorino, Elisa I., Gargano, Romana, Orzechowska-Wylęgała, Bogusława, Wylęgała, Edward, Roszkowska, Anna M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8955972/
https://www.ncbi.nlm.nih.gov/pubmed/35329927
http://dx.doi.org/10.3390/jcm11061602
_version_ 1784676467120013312
author Inferrera, Leandro
Aragona, Emanuela
Wylęgała, Adam
Valastro, Antonio
Latino, Gianluigi
Postorino, Elisa I.
Gargano, Romana
Orzechowska-Wylęgała, Bogusława
Wylęgała, Edward
Roszkowska, Anna M.
author_facet Inferrera, Leandro
Aragona, Emanuela
Wylęgała, Adam
Valastro, Antonio
Latino, Gianluigi
Postorino, Elisa I.
Gargano, Romana
Orzechowska-Wylęgała, Bogusława
Wylęgała, Edward
Roszkowska, Anna M.
author_sort Inferrera, Leandro
collection PubMed
description To prove the role of high-tech investigation in monitoring corneal morphological changes in patients with neurotrophic keratopathy (NK) using Keratograph 5M (K5M) and anterior segment OCT (AS-OCT), corneal healing was monitored with Keratograph 5M (Oculus, Wetzlar, Germany) and AS-OCT (DRI, Triton, Topcon, Tokyo, Japan) in 13 patients (8F and 5M), aged from 24 to 93 years (67.8 ± 19) with severe NK, who were treated with Cenegermin 0.002% (20 μg/mL) (Oxervate(®), Dompè, Farmaceutici Spa, Milan, Italy). The surface defects were evaluated on Keratograph 5M with ImageJ software and the corneal thickness variations were measured using DRI-Triton OCT software. Instrumental procedures were performed at baseline, and after 4 and 8 weeks of the treatment, respectively. The main outcome measures were reduction of the ulcers’ area and corneal thickness recovery. The mean area of the corneal ulcers was reduced between baseline and 4 weeks examination in all patients, and at 8 weeks all ulcers were completely healed. An increase of the corneal thickness was evidenced between the baseline visit and after the 4- and 8-week follow-up, respectively. Additionally, only in collaborating subjects the In Vivo Confocal Microscopy (IVCM) was performed with HRT Rostock Cornea Module (Heidelberg Eng GmbH) to study the corneal nerves fibres. High-tech diagnostics with K5M, AS-OCT and IVCM proved useful in the assessment of corneal morphology and the healing process in patients with NK and could be extended to assess other corneal pathologies.
format Online
Article
Text
id pubmed-8955972
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89559722022-03-26 The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy Inferrera, Leandro Aragona, Emanuela Wylęgała, Adam Valastro, Antonio Latino, Gianluigi Postorino, Elisa I. Gargano, Romana Orzechowska-Wylęgała, Bogusława Wylęgała, Edward Roszkowska, Anna M. J Clin Med Article To prove the role of high-tech investigation in monitoring corneal morphological changes in patients with neurotrophic keratopathy (NK) using Keratograph 5M (K5M) and anterior segment OCT (AS-OCT), corneal healing was monitored with Keratograph 5M (Oculus, Wetzlar, Germany) and AS-OCT (DRI, Triton, Topcon, Tokyo, Japan) in 13 patients (8F and 5M), aged from 24 to 93 years (67.8 ± 19) with severe NK, who were treated with Cenegermin 0.002% (20 μg/mL) (Oxervate(®), Dompè, Farmaceutici Spa, Milan, Italy). The surface defects were evaluated on Keratograph 5M with ImageJ software and the corneal thickness variations were measured using DRI-Triton OCT software. Instrumental procedures were performed at baseline, and after 4 and 8 weeks of the treatment, respectively. The main outcome measures were reduction of the ulcers’ area and corneal thickness recovery. The mean area of the corneal ulcers was reduced between baseline and 4 weeks examination in all patients, and at 8 weeks all ulcers were completely healed. An increase of the corneal thickness was evidenced between the baseline visit and after the 4- and 8-week follow-up, respectively. Additionally, only in collaborating subjects the In Vivo Confocal Microscopy (IVCM) was performed with HRT Rostock Cornea Module (Heidelberg Eng GmbH) to study the corneal nerves fibres. High-tech diagnostics with K5M, AS-OCT and IVCM proved useful in the assessment of corneal morphology and the healing process in patients with NK and could be extended to assess other corneal pathologies. MDPI 2022-03-14 /pmc/articles/PMC8955972/ /pubmed/35329927 http://dx.doi.org/10.3390/jcm11061602 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Inferrera, Leandro
Aragona, Emanuela
Wylęgała, Adam
Valastro, Antonio
Latino, Gianluigi
Postorino, Elisa I.
Gargano, Romana
Orzechowska-Wylęgała, Bogusława
Wylęgała, Edward
Roszkowska, Anna M.
The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy
title The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy
title_full The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy
title_fullStr The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy
title_full_unstemmed The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy
title_short The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy
title_sort role of hi-tech devices in assessment of corneal healing in patients with neurotrophic keratopathy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8955972/
https://www.ncbi.nlm.nih.gov/pubmed/35329927
http://dx.doi.org/10.3390/jcm11061602
work_keys_str_mv AT inferreraleandro theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT aragonaemanuela theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT wylegałaadam theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT valastroantonio theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT latinogianluigi theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT postorinoelisai theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT garganoromana theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT orzechowskawylegałabogusława theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT wylegałaedward theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT roszkowskaannam theroleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT inferreraleandro roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT aragonaemanuela roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT wylegałaadam roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT valastroantonio roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT latinogianluigi roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT postorinoelisai roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT garganoromana roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT orzechowskawylegałabogusława roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT wylegałaedward roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy
AT roszkowskaannam roleofhitechdevicesinassessmentofcornealhealinginpatientswithneurotrophickeratopathy