Cargando…
Frequency Shifts in Muscle Activation during Static Strength Elements on the Rings before and after an Eccentric Training Intervention in Male Gymnasts
During ring performance in men’s gymnastics, static strength elements require a high level of maximal muscular strength. The aim of the study was to analyze the effect of a four-week eccentric–isokinetic training intervention in the frequency spectra of the wavelet-transformed electromyogram (EMG) d...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8956077/ https://www.ncbi.nlm.nih.gov/pubmed/35323611 http://dx.doi.org/10.3390/jfmk7010028 |
_version_ | 1784676490531569664 |
---|---|
author | Göpfert, Beat Schärer, Christoph Tacchelli, Lisa Gross, Micah Lüthy, Fabian Hübner, Klaus |
author_facet | Göpfert, Beat Schärer, Christoph Tacchelli, Lisa Gross, Micah Lüthy, Fabian Hübner, Klaus |
author_sort | Göpfert, Beat |
collection | PubMed |
description | During ring performance in men’s gymnastics, static strength elements require a high level of maximal muscular strength. The aim of the study was to analyze the effect of a four-week eccentric–isokinetic training intervention in the frequency spectra of the wavelet-transformed electromyogram (EMG) during the two static strength elements, the swallow and support scale, in different time intervals during the performance. The gymnasts performed an instrumented movement analysis on the rings, once before the intervention and twice after. For both elements, the results showed a lower congruence in the correlation of the frequency spectra between the first and the last 0.5 s interval than between the first and second 0.5 s intervals, which was indicated by a shift toward the predominant frequency around the wavelet with a center frequency of 62 Hz (Wavelet W10). Furthermore, in both elements, there was a significant increase in the congruence of the frequency spectra after the intervention between the first and second 0.5 s intervals, but not between the first and last ones. In conclusion, the EMG wavelet spectra presented changes corresponding to the performance gain with the eccentric training intervention, and showed the frequency shift toward a predominant frequency due to acute muscular fatigue. |
format | Online Article Text |
id | pubmed-8956077 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89560772022-03-26 Frequency Shifts in Muscle Activation during Static Strength Elements on the Rings before and after an Eccentric Training Intervention in Male Gymnasts Göpfert, Beat Schärer, Christoph Tacchelli, Lisa Gross, Micah Lüthy, Fabian Hübner, Klaus J Funct Morphol Kinesiol Article During ring performance in men’s gymnastics, static strength elements require a high level of maximal muscular strength. The aim of the study was to analyze the effect of a four-week eccentric–isokinetic training intervention in the frequency spectra of the wavelet-transformed electromyogram (EMG) during the two static strength elements, the swallow and support scale, in different time intervals during the performance. The gymnasts performed an instrumented movement analysis on the rings, once before the intervention and twice after. For both elements, the results showed a lower congruence in the correlation of the frequency spectra between the first and the last 0.5 s interval than between the first and second 0.5 s intervals, which was indicated by a shift toward the predominant frequency around the wavelet with a center frequency of 62 Hz (Wavelet W10). Furthermore, in both elements, there was a significant increase in the congruence of the frequency spectra after the intervention between the first and second 0.5 s intervals, but not between the first and last ones. In conclusion, the EMG wavelet spectra presented changes corresponding to the performance gain with the eccentric training intervention, and showed the frequency shift toward a predominant frequency due to acute muscular fatigue. MDPI 2022-03-11 /pmc/articles/PMC8956077/ /pubmed/35323611 http://dx.doi.org/10.3390/jfmk7010028 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Göpfert, Beat Schärer, Christoph Tacchelli, Lisa Gross, Micah Lüthy, Fabian Hübner, Klaus Frequency Shifts in Muscle Activation during Static Strength Elements on the Rings before and after an Eccentric Training Intervention in Male Gymnasts |
title | Frequency Shifts in Muscle Activation during Static Strength Elements on the Rings before and after an Eccentric Training Intervention in Male Gymnasts |
title_full | Frequency Shifts in Muscle Activation during Static Strength Elements on the Rings before and after an Eccentric Training Intervention in Male Gymnasts |
title_fullStr | Frequency Shifts in Muscle Activation during Static Strength Elements on the Rings before and after an Eccentric Training Intervention in Male Gymnasts |
title_full_unstemmed | Frequency Shifts in Muscle Activation during Static Strength Elements on the Rings before and after an Eccentric Training Intervention in Male Gymnasts |
title_short | Frequency Shifts in Muscle Activation during Static Strength Elements on the Rings before and after an Eccentric Training Intervention in Male Gymnasts |
title_sort | frequency shifts in muscle activation during static strength elements on the rings before and after an eccentric training intervention in male gymnasts |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8956077/ https://www.ncbi.nlm.nih.gov/pubmed/35323611 http://dx.doi.org/10.3390/jfmk7010028 |
work_keys_str_mv | AT gopfertbeat frequencyshiftsinmuscleactivationduringstaticstrengthelementsontheringsbeforeandafteraneccentrictraininginterventioninmalegymnasts AT scharerchristoph frequencyshiftsinmuscleactivationduringstaticstrengthelementsontheringsbeforeandafteraneccentrictraininginterventioninmalegymnasts AT tacchellilisa frequencyshiftsinmuscleactivationduringstaticstrengthelementsontheringsbeforeandafteraneccentrictraininginterventioninmalegymnasts AT grossmicah frequencyshiftsinmuscleactivationduringstaticstrengthelementsontheringsbeforeandafteraneccentrictraininginterventioninmalegymnasts AT luthyfabian frequencyshiftsinmuscleactivationduringstaticstrengthelementsontheringsbeforeandafteraneccentrictraininginterventioninmalegymnasts AT hubnerklaus frequencyshiftsinmuscleactivationduringstaticstrengthelementsontheringsbeforeandafteraneccentrictraininginterventioninmalegymnasts |