Cargando…

Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy

PURPOSE: This study aimed to evaluate the medium-term fit of soft contact lenses (SCLs) and its effects on dry eye by using ultra-high-resolution optical coherence tomography (UHR-OCT) and digital slit-lamp biomicroscopy (DSLB) and identify factors indicating a better contact lens fit. METHODS: A to...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yuzhou, Xu, Zhiqiang, Chen, Shuangjiao, Xu, Yangyang, Wei, Linzhi, Lu, Fan, Hu, Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8956436/
https://www.ncbi.nlm.nih.gov/pubmed/35340415
http://dx.doi.org/10.1155/2022/7220706
_version_ 1784676569323667456
author Wang, Yuzhou
Xu, Zhiqiang
Chen, Shuangjiao
Xu, Yangyang
Wei, Linzhi
Lu, Fan
Hu, Liang
author_facet Wang, Yuzhou
Xu, Zhiqiang
Chen, Shuangjiao
Xu, Yangyang
Wei, Linzhi
Lu, Fan
Hu, Liang
author_sort Wang, Yuzhou
collection PubMed
description PURPOSE: This study aimed to evaluate the medium-term fit of soft contact lenses (SCLs) and its effects on dry eye by using ultra-high-resolution optical coherence tomography (UHR-OCT) and digital slit-lamp biomicroscopy (DSLB) and identify factors indicating a better contact lens fit. METHODS: A total of 14 participants (7 men, 7 women; mean age, 23.1 years) were recruited. Temporal lag and conjunctival coverage were imaged by UHR-OCT. DSLB was used to assess lens decentration and blink-induced movement. In addition, dry eye indices, including ocular surface disease index (OSDI), tear break-up time (TBUT), and Schirmer I test scores, were measured at baseline and 1 day, 1 week, 1 month, 3 months, and 6 months after wearing. RESULTS: Good repeatability was found in the assessments of lens fit characteristics by two researchers and in the assessments by one researcher at different follow-up times. There were no significant differences in lens fit characteristics, TBUT and Schirmer I test scores at each checkpoint (P >0.05). However, the OSDI was significantly higher than baseline after wearing (P <0.05). Changes in the temporal lag were positively correlated with changes in TBUT (r =0.544, P =0.044) and negatively correlated with changes in OSDI (r = -0.629, P =0.016). Changes in blink-induced movement were positively correlated with changes in OSDI, Schirmer I test scores, and TBUT (P <0.05). CONCLUSIONS: UHR-OCT and DSLB can be used to comprehensively and quantitatively evaluate SCL fit. Both the contact lenses and ocular surface conditions are almost stable within 6 months of SCL wear. Temporal lag and blink-induced movement have a strong correlation with dry eye parameters in SCL wearers.
format Online
Article
Text
id pubmed-8956436
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-89564362022-03-26 Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy Wang, Yuzhou Xu, Zhiqiang Chen, Shuangjiao Xu, Yangyang Wei, Linzhi Lu, Fan Hu, Liang Dis Markers Research Article PURPOSE: This study aimed to evaluate the medium-term fit of soft contact lenses (SCLs) and its effects on dry eye by using ultra-high-resolution optical coherence tomography (UHR-OCT) and digital slit-lamp biomicroscopy (DSLB) and identify factors indicating a better contact lens fit. METHODS: A total of 14 participants (7 men, 7 women; mean age, 23.1 years) were recruited. Temporal lag and conjunctival coverage were imaged by UHR-OCT. DSLB was used to assess lens decentration and blink-induced movement. In addition, dry eye indices, including ocular surface disease index (OSDI), tear break-up time (TBUT), and Schirmer I test scores, were measured at baseline and 1 day, 1 week, 1 month, 3 months, and 6 months after wearing. RESULTS: Good repeatability was found in the assessments of lens fit characteristics by two researchers and in the assessments by one researcher at different follow-up times. There were no significant differences in lens fit characteristics, TBUT and Schirmer I test scores at each checkpoint (P >0.05). However, the OSDI was significantly higher than baseline after wearing (P <0.05). Changes in the temporal lag were positively correlated with changes in TBUT (r =0.544, P =0.044) and negatively correlated with changes in OSDI (r = -0.629, P =0.016). Changes in blink-induced movement were positively correlated with changes in OSDI, Schirmer I test scores, and TBUT (P <0.05). CONCLUSIONS: UHR-OCT and DSLB can be used to comprehensively and quantitatively evaluate SCL fit. Both the contact lenses and ocular surface conditions are almost stable within 6 months of SCL wear. Temporal lag and blink-induced movement have a strong correlation with dry eye parameters in SCL wearers. Hindawi 2022-03-18 /pmc/articles/PMC8956436/ /pubmed/35340415 http://dx.doi.org/10.1155/2022/7220706 Text en Copyright © 2022 Yuzhou Wang et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Wang, Yuzhou
Xu, Zhiqiang
Chen, Shuangjiao
Xu, Yangyang
Wei, Linzhi
Lu, Fan
Hu, Liang
Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy
title Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy
title_full Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy
title_fullStr Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy
title_full_unstemmed Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy
title_short Effects of Medium-Term Soft Contact Lens Fitting on Dry Eye: Analyses Using Ultra-High Resolution Optical Coherence Tomography and Digital Slit-Lamp Biomicroscopy
title_sort effects of medium-term soft contact lens fitting on dry eye: analyses using ultra-high resolution optical coherence tomography and digital slit-lamp biomicroscopy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8956436/
https://www.ncbi.nlm.nih.gov/pubmed/35340415
http://dx.doi.org/10.1155/2022/7220706
work_keys_str_mv AT wangyuzhou effectsofmediumtermsoftcontactlensfittingondryeyeanalysesusingultrahighresolutionopticalcoherencetomographyanddigitalslitlampbiomicroscopy
AT xuzhiqiang effectsofmediumtermsoftcontactlensfittingondryeyeanalysesusingultrahighresolutionopticalcoherencetomographyanddigitalslitlampbiomicroscopy
AT chenshuangjiao effectsofmediumtermsoftcontactlensfittingondryeyeanalysesusingultrahighresolutionopticalcoherencetomographyanddigitalslitlampbiomicroscopy
AT xuyangyang effectsofmediumtermsoftcontactlensfittingondryeyeanalysesusingultrahighresolutionopticalcoherencetomographyanddigitalslitlampbiomicroscopy
AT weilinzhi effectsofmediumtermsoftcontactlensfittingondryeyeanalysesusingultrahighresolutionopticalcoherencetomographyanddigitalslitlampbiomicroscopy
AT lufan effectsofmediumtermsoftcontactlensfittingondryeyeanalysesusingultrahighresolutionopticalcoherencetomographyanddigitalslitlampbiomicroscopy
AT huliang effectsofmediumtermsoftcontactlensfittingondryeyeanalysesusingultrahighresolutionopticalcoherencetomographyanddigitalslitlampbiomicroscopy