Cargando…

Radiomics of Patients with Locally Advanced Rectal Cancer: Effect of Preprocessing on Features Estimation from Computed Tomography Imaging

The purpose of this study was to investigate the effect of image preprocessing on radiomic features estimation from computed tomography (CT) imaging of locally advanced rectal cancer (LARC). CT images of 20 patients with LARC were used to estimate 105 radiomic features of 7 classes (shape, first-ord...

Descripción completa

Detalles Bibliográficos
Autores principales: Linsalata, Stefania, Borgheresi, Rita, Marfisi, Daniela, Barca, Patrizio, Sainato, Aldo, Paiar, Fabiola, Neri, Emanuele, Traino, Antonio Claudio, Giannelli, Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8958068/
https://www.ncbi.nlm.nih.gov/pubmed/35355820
http://dx.doi.org/10.1155/2022/2003286
_version_ 1784676870775635968
author Linsalata, Stefania
Borgheresi, Rita
Marfisi, Daniela
Barca, Patrizio
Sainato, Aldo
Paiar, Fabiola
Neri, Emanuele
Traino, Antonio Claudio
Giannelli, Marco
author_facet Linsalata, Stefania
Borgheresi, Rita
Marfisi, Daniela
Barca, Patrizio
Sainato, Aldo
Paiar, Fabiola
Neri, Emanuele
Traino, Antonio Claudio
Giannelli, Marco
author_sort Linsalata, Stefania
collection PubMed
description The purpose of this study was to investigate the effect of image preprocessing on radiomic features estimation from computed tomography (CT) imaging of locally advanced rectal cancer (LARC). CT images of 20 patients with LARC were used to estimate 105 radiomic features of 7 classes (shape, first-order, GLCM, GLDM, GLRLM, GLSZM, and NGTDM). Radiomic features were estimated for 6 different isotropic resampling voxel sizes, using 10 interpolation algorithms (at fixed bin width) and 6 different bin widths (at fixed interpolation algorithm). The intraclass correlation coefficient (ICC) and the coefficient of variation (CV) were calculated to assess the variability in radiomic features estimation due to preprocessing. A repeated measures correlation analysis was performed to assess any linear correlation between radiomic feature estimate and resampling voxel size or bin width. Reproducibility of radiomic feature estimate, when assessed through ICC analysis, was nominally excellent (ICC > 0.9) for shape features, good (0.75 < ICC ≤ 0.9) or moderate (0.5 < ICC ≤ 0.75) for first-order features, and moderate or poor (0 ≤ ICC ≤ 0.5) for textural features. A number of radiomic features characterized by good or excellent reproducibility in terms of ICC showed however median CV values greater than 15%. For most textural features, a significant (p < 0.05) correlation between their estimate and resampling voxel size or bin width was found. In CT imaging of patients with LARC, the estimate of textural features, as well as of first-order features to a lesser extent, is appreciably biased by preprocessing. Accordingly, this should be taken into account when planning clinical or research studies, as well as when comparing results from different studies and performing multicenter studies.
format Online
Article
Text
id pubmed-8958068
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-89580682022-03-29 Radiomics of Patients with Locally Advanced Rectal Cancer: Effect of Preprocessing on Features Estimation from Computed Tomography Imaging Linsalata, Stefania Borgheresi, Rita Marfisi, Daniela Barca, Patrizio Sainato, Aldo Paiar, Fabiola Neri, Emanuele Traino, Antonio Claudio Giannelli, Marco Biomed Res Int Research Article The purpose of this study was to investigate the effect of image preprocessing on radiomic features estimation from computed tomography (CT) imaging of locally advanced rectal cancer (LARC). CT images of 20 patients with LARC were used to estimate 105 radiomic features of 7 classes (shape, first-order, GLCM, GLDM, GLRLM, GLSZM, and NGTDM). Radiomic features were estimated for 6 different isotropic resampling voxel sizes, using 10 interpolation algorithms (at fixed bin width) and 6 different bin widths (at fixed interpolation algorithm). The intraclass correlation coefficient (ICC) and the coefficient of variation (CV) were calculated to assess the variability in radiomic features estimation due to preprocessing. A repeated measures correlation analysis was performed to assess any linear correlation between radiomic feature estimate and resampling voxel size or bin width. Reproducibility of radiomic feature estimate, when assessed through ICC analysis, was nominally excellent (ICC > 0.9) for shape features, good (0.75 < ICC ≤ 0.9) or moderate (0.5 < ICC ≤ 0.75) for first-order features, and moderate or poor (0 ≤ ICC ≤ 0.5) for textural features. A number of radiomic features characterized by good or excellent reproducibility in terms of ICC showed however median CV values greater than 15%. For most textural features, a significant (p < 0.05) correlation between their estimate and resampling voxel size or bin width was found. In CT imaging of patients with LARC, the estimate of textural features, as well as of first-order features to a lesser extent, is appreciably biased by preprocessing. Accordingly, this should be taken into account when planning clinical or research studies, as well as when comparing results from different studies and performing multicenter studies. Hindawi 2022-03-20 /pmc/articles/PMC8958068/ /pubmed/35355820 http://dx.doi.org/10.1155/2022/2003286 Text en Copyright © 2022 Stefania Linsalata et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Linsalata, Stefania
Borgheresi, Rita
Marfisi, Daniela
Barca, Patrizio
Sainato, Aldo
Paiar, Fabiola
Neri, Emanuele
Traino, Antonio Claudio
Giannelli, Marco
Radiomics of Patients with Locally Advanced Rectal Cancer: Effect of Preprocessing on Features Estimation from Computed Tomography Imaging
title Radiomics of Patients with Locally Advanced Rectal Cancer: Effect of Preprocessing on Features Estimation from Computed Tomography Imaging
title_full Radiomics of Patients with Locally Advanced Rectal Cancer: Effect of Preprocessing on Features Estimation from Computed Tomography Imaging
title_fullStr Radiomics of Patients with Locally Advanced Rectal Cancer: Effect of Preprocessing on Features Estimation from Computed Tomography Imaging
title_full_unstemmed Radiomics of Patients with Locally Advanced Rectal Cancer: Effect of Preprocessing on Features Estimation from Computed Tomography Imaging
title_short Radiomics of Patients with Locally Advanced Rectal Cancer: Effect of Preprocessing on Features Estimation from Computed Tomography Imaging
title_sort radiomics of patients with locally advanced rectal cancer: effect of preprocessing on features estimation from computed tomography imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8958068/
https://www.ncbi.nlm.nih.gov/pubmed/35355820
http://dx.doi.org/10.1155/2022/2003286
work_keys_str_mv AT linsalatastefania radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging
AT borgheresirita radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging
AT marfisidaniela radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging
AT barcapatrizio radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging
AT sainatoaldo radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging
AT paiarfabiola radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging
AT neriemanuele radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging
AT trainoantonioclaudio radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging
AT giannellimarco radiomicsofpatientswithlocallyadvancedrectalcancereffectofpreprocessingonfeaturesestimationfromcomputedtomographyimaging