Cargando…
Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy
The tilted implant with immediate function is increasingly used in clinical dental therapy for edentulous and partially edentulous patients with excessive bone resorption and the anatomic limitations in the alveolar ridge. However, peri-implant cervical bone loss can be caused by the stress shieldin...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
KeAi Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8958422/ https://www.ncbi.nlm.nih.gov/pubmed/35386333 http://dx.doi.org/10.1016/j.bioactmat.2022.03.005 |
_version_ | 1784676939439538176 |
---|---|
author | Mao, Chuanyuan Yu, Weijun Jin, Min Wang, Yingchen Shang, Xiaoqing Lin, Lu Zeng, Xiaoqin Wang, Liqiang Lu, Eryi |
author_facet | Mao, Chuanyuan Yu, Weijun Jin, Min Wang, Yingchen Shang, Xiaoqing Lin, Lu Zeng, Xiaoqin Wang, Liqiang Lu, Eryi |
author_sort | Mao, Chuanyuan |
collection | PubMed |
description | The tilted implant with immediate function is increasingly used in clinical dental therapy for edentulous and partially edentulous patients with excessive bone resorption and the anatomic limitations in the alveolar ridge. However, peri-implant cervical bone loss can be caused by the stress shielding effect. Herein, inspired by the concept of “materiobiology”, the mechanical characteristics of materials were considered along with bone biology for tilted implant design. In this study, a novel Ti–35Nb–2Ta–3Zr alloy (TNTZ) implant with low elastic modulus, high strength and favorable biocompatibility was developed. Then the human alveolar bone environment was mimicked in goat and finite element (FE) models to investigate the mechanical property and the related peri-implant bone remodeling of TNTZ compared to commonly used Ti–6Al–4V (TC4) in tilted implantation under loading condition. Next, a layer-by-layer quantitative correlation of the FE and X-ray Microscopy (XRM) analysis suggested that the TNTZ implant present better mechanobiological characteristics including improved load transduction and increased bone area in the tilted implantation model compared to TC4 implant, especially in the upper 1/3 region of peri-implant bone that is “lower stress”. Finally, combining the static and dynamic parameters of bone, it was further verified that TNTZ enhanced bone remodeling in “lower stress” upper 1/3 region. This study demonstrates that TNTZ is a mechanobiological optimized tilted implant material that enhances load transduction and bone remodeling. |
format | Online Article Text |
id | pubmed-8958422 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | KeAi Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-89584222022-04-05 Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy Mao, Chuanyuan Yu, Weijun Jin, Min Wang, Yingchen Shang, Xiaoqing Lin, Lu Zeng, Xiaoqin Wang, Liqiang Lu, Eryi Bioact Mater Article The tilted implant with immediate function is increasingly used in clinical dental therapy for edentulous and partially edentulous patients with excessive bone resorption and the anatomic limitations in the alveolar ridge. However, peri-implant cervical bone loss can be caused by the stress shielding effect. Herein, inspired by the concept of “materiobiology”, the mechanical characteristics of materials were considered along with bone biology for tilted implant design. In this study, a novel Ti–35Nb–2Ta–3Zr alloy (TNTZ) implant with low elastic modulus, high strength and favorable biocompatibility was developed. Then the human alveolar bone environment was mimicked in goat and finite element (FE) models to investigate the mechanical property and the related peri-implant bone remodeling of TNTZ compared to commonly used Ti–6Al–4V (TC4) in tilted implantation under loading condition. Next, a layer-by-layer quantitative correlation of the FE and X-ray Microscopy (XRM) analysis suggested that the TNTZ implant present better mechanobiological characteristics including improved load transduction and increased bone area in the tilted implantation model compared to TC4 implant, especially in the upper 1/3 region of peri-implant bone that is “lower stress”. Finally, combining the static and dynamic parameters of bone, it was further verified that TNTZ enhanced bone remodeling in “lower stress” upper 1/3 region. This study demonstrates that TNTZ is a mechanobiological optimized tilted implant material that enhances load transduction and bone remodeling. KeAi Publishing 2022-03-16 /pmc/articles/PMC8958422/ /pubmed/35386333 http://dx.doi.org/10.1016/j.bioactmat.2022.03.005 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Mao, Chuanyuan Yu, Weijun Jin, Min Wang, Yingchen Shang, Xiaoqing Lin, Lu Zeng, Xiaoqin Wang, Liqiang Lu, Eryi Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy |
title | Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy |
title_full | Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy |
title_fullStr | Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy |
title_full_unstemmed | Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy |
title_short | Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy |
title_sort | mechanobiologically optimized ti–35nb–2ta–3zr improves load transduction and enhances bone remodeling in tilted dental implant therapy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8958422/ https://www.ncbi.nlm.nih.gov/pubmed/35386333 http://dx.doi.org/10.1016/j.bioactmat.2022.03.005 |
work_keys_str_mv | AT maochuanyuan mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy AT yuweijun mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy AT jinmin mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy AT wangyingchen mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy AT shangxiaoqing mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy AT linlu mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy AT zengxiaoqin mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy AT wangliqiang mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy AT lueryi mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy |