Cargando…

Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy

The tilted implant with immediate function is increasingly used in clinical dental therapy for edentulous and partially edentulous patients with excessive bone resorption and the anatomic limitations in the alveolar ridge. However, peri-implant cervical bone loss can be caused by the stress shieldin...

Descripción completa

Detalles Bibliográficos
Autores principales: Mao, Chuanyuan, Yu, Weijun, Jin, Min, Wang, Yingchen, Shang, Xiaoqing, Lin, Lu, Zeng, Xiaoqin, Wang, Liqiang, Lu, Eryi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: KeAi Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8958422/
https://www.ncbi.nlm.nih.gov/pubmed/35386333
http://dx.doi.org/10.1016/j.bioactmat.2022.03.005
_version_ 1784676939439538176
author Mao, Chuanyuan
Yu, Weijun
Jin, Min
Wang, Yingchen
Shang, Xiaoqing
Lin, Lu
Zeng, Xiaoqin
Wang, Liqiang
Lu, Eryi
author_facet Mao, Chuanyuan
Yu, Weijun
Jin, Min
Wang, Yingchen
Shang, Xiaoqing
Lin, Lu
Zeng, Xiaoqin
Wang, Liqiang
Lu, Eryi
author_sort Mao, Chuanyuan
collection PubMed
description The tilted implant with immediate function is increasingly used in clinical dental therapy for edentulous and partially edentulous patients with excessive bone resorption and the anatomic limitations in the alveolar ridge. However, peri-implant cervical bone loss can be caused by the stress shielding effect. Herein, inspired by the concept of “materiobiology”, the mechanical characteristics of materials were considered along with bone biology for tilted implant design. In this study, a novel Ti–35Nb–2Ta–3Zr alloy (TNTZ) implant with low elastic modulus, high strength and favorable biocompatibility was developed. Then the human alveolar bone environment was mimicked in goat and finite element (FE) models to investigate the mechanical property and the related peri-implant bone remodeling of TNTZ compared to commonly used Ti–6Al–4V (TC4) in tilted implantation under loading condition. Next, a layer-by-layer quantitative correlation of the FE and X-ray Microscopy (XRM) analysis suggested that the TNTZ implant present better mechanobiological characteristics including improved load transduction and increased bone area in the tilted implantation model compared to TC4 implant, especially in the upper 1/3 region of peri-implant bone that is “lower stress”. Finally, combining the static and dynamic parameters of bone, it was further verified that TNTZ enhanced bone remodeling in “lower stress” upper 1/3 region. This study demonstrates that TNTZ is a mechanobiological optimized tilted implant material that enhances load transduction and bone remodeling.
format Online
Article
Text
id pubmed-8958422
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher KeAi Publishing
record_format MEDLINE/PubMed
spelling pubmed-89584222022-04-05 Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy Mao, Chuanyuan Yu, Weijun Jin, Min Wang, Yingchen Shang, Xiaoqing Lin, Lu Zeng, Xiaoqin Wang, Liqiang Lu, Eryi Bioact Mater Article The tilted implant with immediate function is increasingly used in clinical dental therapy for edentulous and partially edentulous patients with excessive bone resorption and the anatomic limitations in the alveolar ridge. However, peri-implant cervical bone loss can be caused by the stress shielding effect. Herein, inspired by the concept of “materiobiology”, the mechanical characteristics of materials were considered along with bone biology for tilted implant design. In this study, a novel Ti–35Nb–2Ta–3Zr alloy (TNTZ) implant with low elastic modulus, high strength and favorable biocompatibility was developed. Then the human alveolar bone environment was mimicked in goat and finite element (FE) models to investigate the mechanical property and the related peri-implant bone remodeling of TNTZ compared to commonly used Ti–6Al–4V (TC4) in tilted implantation under loading condition. Next, a layer-by-layer quantitative correlation of the FE and X-ray Microscopy (XRM) analysis suggested that the TNTZ implant present better mechanobiological characteristics including improved load transduction and increased bone area in the tilted implantation model compared to TC4 implant, especially in the upper 1/3 region of peri-implant bone that is “lower stress”. Finally, combining the static and dynamic parameters of bone, it was further verified that TNTZ enhanced bone remodeling in “lower stress” upper 1/3 region. This study demonstrates that TNTZ is a mechanobiological optimized tilted implant material that enhances load transduction and bone remodeling. KeAi Publishing 2022-03-16 /pmc/articles/PMC8958422/ /pubmed/35386333 http://dx.doi.org/10.1016/j.bioactmat.2022.03.005 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Mao, Chuanyuan
Yu, Weijun
Jin, Min
Wang, Yingchen
Shang, Xiaoqing
Lin, Lu
Zeng, Xiaoqin
Wang, Liqiang
Lu, Eryi
Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy
title Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy
title_full Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy
title_fullStr Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy
title_full_unstemmed Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy
title_short Mechanobiologically optimized Ti–35Nb–2Ta–3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy
title_sort mechanobiologically optimized ti–35nb–2ta–3zr improves load transduction and enhances bone remodeling in tilted dental implant therapy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8958422/
https://www.ncbi.nlm.nih.gov/pubmed/35386333
http://dx.doi.org/10.1016/j.bioactmat.2022.03.005
work_keys_str_mv AT maochuanyuan mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy
AT yuweijun mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy
AT jinmin mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy
AT wangyingchen mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy
AT shangxiaoqing mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy
AT linlu mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy
AT zengxiaoqin mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy
AT wangliqiang mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy
AT lueryi mechanobiologicallyoptimizedti35nb2ta3zrimprovesloadtransductionandenhancesboneremodelingintilteddentalimplanttherapy