Cargando…
2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection
PURPOSE: To assess the ability of 2D-Shear wave elastography (2D-SWE) to evaluate its reproducibility, to define the optimal orientation and size of the region of interest (ROI), and to differentiate benign from malignant inguinal lymph nodes (LNs). METHOD: Thirty-two suspicious inguinal LNs from 21...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959156/ https://www.ncbi.nlm.nih.gov/pubmed/35344561 http://dx.doi.org/10.1371/journal.pone.0265802 |
_version_ | 1784677086989910016 |
---|---|
author | Lahtinen, Olli Pulkkinen, Mika Sironen, Reijo Vanninen, Ritva Rautiainen, Suvi |
author_facet | Lahtinen, Olli Pulkkinen, Mika Sironen, Reijo Vanninen, Ritva Rautiainen, Suvi |
author_sort | Lahtinen, Olli |
collection | PubMed |
description | PURPOSE: To assess the ability of 2D-Shear wave elastography (2D-SWE) to evaluate its reproducibility, to define the optimal orientation and size of the region of interest (ROI), and to differentiate benign from malignant inguinal lymph nodes (LNs). METHOD: Thirty-two suspicious inguinal LNs from 21 patients were evaluated with 2D-SWE. SWE measurements were obtained in two orthogonal planes. To investigate reproducibility, sensitivity and specificity, circular ROIs with a diameter of 1 mm, 2 mm, 3 mm and 5 mm were placed on the cortex of the LNs. Additionally, one freehand ROI was drawn covering majority of the LN. Two observers performed five sets of SWE measurements for each ROI size. All LNs underwent core needle biopsy or were surgically removed. RESULTS: The 3 mm ROI for Mean-E in axial plane showed high interrater agreement [intraclass correlation coefficient (ICC) 0.899] with the cut-off value of 7.31 kPa resulting in 88.9% sensitivity and 60.9% specificity for differentiating malignant from benign LNs. In benign LNs, mean elasticity of the ROI was lower (7.68 ± 3.82 kPa; range, 3.41–15.40 kPa) compared to the malignant LNs (15.81 ± 10.61 kPa; range, 3.86–36.45 kPa). CONCLUSIONS: The most reproducible way to measure stiffness in inguinal LNs is a 3 mm circular ROI centered on the cortex of the LN in axial plane. Elasticity values were higher in the malignant LNs reflecting the stiffer nature of the metastatic LNs. 2D-SWE offers a noninvasive ultrasonographic tool to assess superficial inguinal lymph nodes with high reproducibility. |
format | Online Article Text |
id | pubmed-8959156 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-89591562022-03-29 2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection Lahtinen, Olli Pulkkinen, Mika Sironen, Reijo Vanninen, Ritva Rautiainen, Suvi PLoS One Research Article PURPOSE: To assess the ability of 2D-Shear wave elastography (2D-SWE) to evaluate its reproducibility, to define the optimal orientation and size of the region of interest (ROI), and to differentiate benign from malignant inguinal lymph nodes (LNs). METHOD: Thirty-two suspicious inguinal LNs from 21 patients were evaluated with 2D-SWE. SWE measurements were obtained in two orthogonal planes. To investigate reproducibility, sensitivity and specificity, circular ROIs with a diameter of 1 mm, 2 mm, 3 mm and 5 mm were placed on the cortex of the LNs. Additionally, one freehand ROI was drawn covering majority of the LN. Two observers performed five sets of SWE measurements for each ROI size. All LNs underwent core needle biopsy or were surgically removed. RESULTS: The 3 mm ROI for Mean-E in axial plane showed high interrater agreement [intraclass correlation coefficient (ICC) 0.899] with the cut-off value of 7.31 kPa resulting in 88.9% sensitivity and 60.9% specificity for differentiating malignant from benign LNs. In benign LNs, mean elasticity of the ROI was lower (7.68 ± 3.82 kPa; range, 3.41–15.40 kPa) compared to the malignant LNs (15.81 ± 10.61 kPa; range, 3.86–36.45 kPa). CONCLUSIONS: The most reproducible way to measure stiffness in inguinal LNs is a 3 mm circular ROI centered on the cortex of the LN in axial plane. Elasticity values were higher in the malignant LNs reflecting the stiffer nature of the metastatic LNs. 2D-SWE offers a noninvasive ultrasonographic tool to assess superficial inguinal lymph nodes with high reproducibility. Public Library of Science 2022-03-28 /pmc/articles/PMC8959156/ /pubmed/35344561 http://dx.doi.org/10.1371/journal.pone.0265802 Text en © 2022 Lahtinen et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Lahtinen, Olli Pulkkinen, Mika Sironen, Reijo Vanninen, Ritva Rautiainen, Suvi 2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection |
title | 2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection |
title_full | 2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection |
title_fullStr | 2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection |
title_full_unstemmed | 2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection |
title_short | 2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection |
title_sort | 2d-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: reproducibility and region of interest selection |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959156/ https://www.ncbi.nlm.nih.gov/pubmed/35344561 http://dx.doi.org/10.1371/journal.pone.0265802 |
work_keys_str_mv | AT lahtinenolli 2dshearwaveelastographyintheevaluationofsuspicioussuperficialinguinallymphnodesreproducibilityandregionofinterestselection AT pulkkinenmika 2dshearwaveelastographyintheevaluationofsuspicioussuperficialinguinallymphnodesreproducibilityandregionofinterestselection AT sironenreijo 2dshearwaveelastographyintheevaluationofsuspicioussuperficialinguinallymphnodesreproducibilityandregionofinterestselection AT vanninenritva 2dshearwaveelastographyintheevaluationofsuspicioussuperficialinguinallymphnodesreproducibilityandregionofinterestselection AT rautiainensuvi 2dshearwaveelastographyintheevaluationofsuspicioussuperficialinguinallymphnodesreproducibilityandregionofinterestselection |