Cargando…

Biomechanical Analysis of a Novel Double-Point Fixation Method for Displaced Intra-Articular Calcaneal Fractures

The development of minimally invasive procedures and implant materials has improved the fixation strength of implants and is less traumatic in surgery. The purpose of this study was to propose a novel “double-point fixation” for calcaneal fractures and compare its biomechanical stability with the tr...

Descripción completa

Detalles Bibliográficos
Autores principales: Lv, Miko Lin, Ni, Ming, Sun, Wanju, Wong, Duo Wai-Chi, Zhou, Shuren, Jia, Yongwei, Zhang, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959616/
https://www.ncbi.nlm.nih.gov/pubmed/35356772
http://dx.doi.org/10.3389/fbioe.2022.791554
_version_ 1784677198596145152
author Lv, Miko Lin
Ni, Ming
Sun, Wanju
Wong, Duo Wai-Chi
Zhou, Shuren
Jia, Yongwei
Zhang, Ming
author_facet Lv, Miko Lin
Ni, Ming
Sun, Wanju
Wong, Duo Wai-Chi
Zhou, Shuren
Jia, Yongwei
Zhang, Ming
author_sort Lv, Miko Lin
collection PubMed
description The development of minimally invasive procedures and implant materials has improved the fixation strength of implants and is less traumatic in surgery. The purpose of this study was to propose a novel “double-point fixation” for calcaneal fractures and compare its biomechanical stability with the traditional “three-point fixation.” A three-dimensional finite element foot model with a Sanders type IIIAB calcaneal fracture was developed based on clinical images comprising bones, plantar fascia, ligaments, and encapsulated soft tissue. Double-point and three-point fixation resembled the surgical procedure with a volar distal radius plate and calcaneal locking plate, respectively. The stress distribution, fracture displacement, and change of the Böhler angle and Gissane’s angle were estimated by a walking simulation using the model, and the predictions between the double-point and three-point fixation were compared at heel-strike, midstance, and push-off instants. Double-point fixation demonstrated lower bone stress (103.3 vs. 199.4 MPa), but higher implant stress (1,084.0 vs. 577.9 MPa). The model displacement of double-point fixation was higher than that of three-point fixation (3.68 vs. 2.53 mm). The displacement of the posterior joint facet (0.127 vs. 0.150 mm) and the changes of the Böhler angle (0.9° vs. 1.4°) and Gissane’s angle (0.7° vs. 0.9°) in double-point fixation were comparably lower. Double-point fixation by volar distal radius plates demonstrated sufficient and favorable fixation stability and a lower risk of postoperative stress fracture, which may potentially serve as a new fixation modality for the treatment of displaced intra-articular calcaneal fractures.
format Online
Article
Text
id pubmed-8959616
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-89596162022-03-29 Biomechanical Analysis of a Novel Double-Point Fixation Method for Displaced Intra-Articular Calcaneal Fractures Lv, Miko Lin Ni, Ming Sun, Wanju Wong, Duo Wai-Chi Zhou, Shuren Jia, Yongwei Zhang, Ming Front Bioeng Biotechnol Bioengineering and Biotechnology The development of minimally invasive procedures and implant materials has improved the fixation strength of implants and is less traumatic in surgery. The purpose of this study was to propose a novel “double-point fixation” for calcaneal fractures and compare its biomechanical stability with the traditional “three-point fixation.” A three-dimensional finite element foot model with a Sanders type IIIAB calcaneal fracture was developed based on clinical images comprising bones, plantar fascia, ligaments, and encapsulated soft tissue. Double-point and three-point fixation resembled the surgical procedure with a volar distal radius plate and calcaneal locking plate, respectively. The stress distribution, fracture displacement, and change of the Böhler angle and Gissane’s angle were estimated by a walking simulation using the model, and the predictions between the double-point and three-point fixation were compared at heel-strike, midstance, and push-off instants. Double-point fixation demonstrated lower bone stress (103.3 vs. 199.4 MPa), but higher implant stress (1,084.0 vs. 577.9 MPa). The model displacement of double-point fixation was higher than that of three-point fixation (3.68 vs. 2.53 mm). The displacement of the posterior joint facet (0.127 vs. 0.150 mm) and the changes of the Böhler angle (0.9° vs. 1.4°) and Gissane’s angle (0.7° vs. 0.9°) in double-point fixation were comparably lower. Double-point fixation by volar distal radius plates demonstrated sufficient and favorable fixation stability and a lower risk of postoperative stress fracture, which may potentially serve as a new fixation modality for the treatment of displaced intra-articular calcaneal fractures. Frontiers Media S.A. 2022-03-09 /pmc/articles/PMC8959616/ /pubmed/35356772 http://dx.doi.org/10.3389/fbioe.2022.791554 Text en Copyright © 2022 Lv, Ni, Sun, Wong, Zhou, Jia and Zhang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Lv, Miko Lin
Ni, Ming
Sun, Wanju
Wong, Duo Wai-Chi
Zhou, Shuren
Jia, Yongwei
Zhang, Ming
Biomechanical Analysis of a Novel Double-Point Fixation Method for Displaced Intra-Articular Calcaneal Fractures
title Biomechanical Analysis of a Novel Double-Point Fixation Method for Displaced Intra-Articular Calcaneal Fractures
title_full Biomechanical Analysis of a Novel Double-Point Fixation Method for Displaced Intra-Articular Calcaneal Fractures
title_fullStr Biomechanical Analysis of a Novel Double-Point Fixation Method for Displaced Intra-Articular Calcaneal Fractures
title_full_unstemmed Biomechanical Analysis of a Novel Double-Point Fixation Method for Displaced Intra-Articular Calcaneal Fractures
title_short Biomechanical Analysis of a Novel Double-Point Fixation Method for Displaced Intra-Articular Calcaneal Fractures
title_sort biomechanical analysis of a novel double-point fixation method for displaced intra-articular calcaneal fractures
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959616/
https://www.ncbi.nlm.nih.gov/pubmed/35356772
http://dx.doi.org/10.3389/fbioe.2022.791554
work_keys_str_mv AT lvmikolin biomechanicalanalysisofanoveldoublepointfixationmethodfordisplacedintraarticularcalcanealfractures
AT niming biomechanicalanalysisofanoveldoublepointfixationmethodfordisplacedintraarticularcalcanealfractures
AT sunwanju biomechanicalanalysisofanoveldoublepointfixationmethodfordisplacedintraarticularcalcanealfractures
AT wongduowaichi biomechanicalanalysisofanoveldoublepointfixationmethodfordisplacedintraarticularcalcanealfractures
AT zhoushuren biomechanicalanalysisofanoveldoublepointfixationmethodfordisplacedintraarticularcalcanealfractures
AT jiayongwei biomechanicalanalysisofanoveldoublepointfixationmethodfordisplacedintraarticularcalcanealfractures
AT zhangming biomechanicalanalysisofanoveldoublepointfixationmethodfordisplacedintraarticularcalcanealfractures