Cargando…

Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material

Background: The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Due to the steadily increasing number of RH prostheses, we aimed to assess the complication frequencies, complication types and clinical outcomes of a modern RH hinge pros...

Descripción completa

Detalles Bibliográficos
Autores principales: Vertesich, Klemens, Staats, Kevin, Böhler, Christoph, Koza, Richard, Lass, Richard, Giurea, Alexander
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959897/
https://www.ncbi.nlm.nih.gov/pubmed/35356773
http://dx.doi.org/10.3389/fbioe.2022.845859
_version_ 1784677264459300864
author Vertesich, Klemens
Staats, Kevin
Böhler, Christoph
Koza, Richard
Lass, Richard
Giurea, Alexander
author_facet Vertesich, Klemens
Staats, Kevin
Böhler, Christoph
Koza, Richard
Lass, Richard
Giurea, Alexander
author_sort Vertesich, Klemens
collection PubMed
description Background: The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Due to the steadily increasing number of RH prostheses, we aimed to assess the complication frequencies, complication types and clinical outcomes of a modern RH hinge prosthesis using a new bearing material with a minimum follow-up of 7 years. Methods: Fifty-six consecutive patients who received the EnduRo(®) RH prosthesis using carbon-fiber reinforced poly-ether-ether-ketone (CFR-PEEK) as bearing material were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively, postoperatively after three and 12 months and annually thereafter. Clinical scores were documented for each patient. Competing risk analysis was assessed with respect to indication and failure mode. Results: Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS) and range of motion (ROM) improved significantly compared to preoperative values (p < 0.0001). The overall cumulative incidence for revision surgery was 23.6% at 7 years and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). Conclusion: The evaluated RH prosthesis provided reliable and durable results for a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of the cases. The use of this RH system in primary patients showed high survival rates and long-term functional outcomes and clinical outcomes proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK.
format Online
Article
Text
id pubmed-8959897
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-89598972022-03-29 Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material Vertesich, Klemens Staats, Kevin Böhler, Christoph Koza, Richard Lass, Richard Giurea, Alexander Front Bioeng Biotechnol Bioengineering and Biotechnology Background: The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Due to the steadily increasing number of RH prostheses, we aimed to assess the complication frequencies, complication types and clinical outcomes of a modern RH hinge prosthesis using a new bearing material with a minimum follow-up of 7 years. Methods: Fifty-six consecutive patients who received the EnduRo(®) RH prosthesis using carbon-fiber reinforced poly-ether-ether-ketone (CFR-PEEK) as bearing material were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively, postoperatively after three and 12 months and annually thereafter. Clinical scores were documented for each patient. Competing risk analysis was assessed with respect to indication and failure mode. Results: Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS) and range of motion (ROM) improved significantly compared to preoperative values (p < 0.0001). The overall cumulative incidence for revision surgery was 23.6% at 7 years and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). Conclusion: The evaluated RH prosthesis provided reliable and durable results for a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of the cases. The use of this RH system in primary patients showed high survival rates and long-term functional outcomes and clinical outcomes proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK. Frontiers Media S.A. 2022-03-04 /pmc/articles/PMC8959897/ /pubmed/35356773 http://dx.doi.org/10.3389/fbioe.2022.845859 Text en Copyright © 2022 Vertesich, Staats, Böhler, Koza, Lass and Giurea. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Vertesich, Klemens
Staats, Kevin
Böhler, Christoph
Koza, Richard
Lass, Richard
Giurea, Alexander
Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material
title Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material
title_full Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material
title_fullStr Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material
title_full_unstemmed Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material
title_short Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material
title_sort long term results of a rotating hinge total knee prosthesis with carbon-fiber reinforced poly-ether-ether-ketone (cfr-peek) as bearing material
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8959897/
https://www.ncbi.nlm.nih.gov/pubmed/35356773
http://dx.doi.org/10.3389/fbioe.2022.845859
work_keys_str_mv AT vertesichklemens longtermresultsofarotatinghingetotalkneeprosthesiswithcarbonfiberreinforcedpolyetheretherketonecfrpeekasbearingmaterial
AT staatskevin longtermresultsofarotatinghingetotalkneeprosthesiswithcarbonfiberreinforcedpolyetheretherketonecfrpeekasbearingmaterial
AT bohlerchristoph longtermresultsofarotatinghingetotalkneeprosthesiswithcarbonfiberreinforcedpolyetheretherketonecfrpeekasbearingmaterial
AT kozarichard longtermresultsofarotatinghingetotalkneeprosthesiswithcarbonfiberreinforcedpolyetheretherketonecfrpeekasbearingmaterial
AT lassrichard longtermresultsofarotatinghingetotalkneeprosthesiswithcarbonfiberreinforcedpolyetheretherketonecfrpeekasbearingmaterial
AT giureaalexander longtermresultsofarotatinghingetotalkneeprosthesiswithcarbonfiberreinforcedpolyetheretherketonecfrpeekasbearingmaterial