Cargando…
Assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children
BACKGROUND: Accurate measurements of left ventricular (LV) volumes and function are important in the management of patients with various cardiac abnormalities. Two-dimensional (2D) speckle tracking echocardiography (STE) is shown to be accurate in detecting subclinical myocardial dysfunction when mo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8960099/ https://www.ncbi.nlm.nih.gov/pubmed/35347471 http://dx.doi.org/10.1186/s43044-022-00258-w |
_version_ | 1784677314654633984 |
---|---|
author | Kamel, Heba Elsayegh, Ayah Tarek Nazmi, Hany Attia, Hebatallah Mohamed |
author_facet | Kamel, Heba Elsayegh, Ayah Tarek Nazmi, Hany Attia, Hebatallah Mohamed |
author_sort | Kamel, Heba |
collection | PubMed |
description | BACKGROUND: Accurate measurements of left ventricular (LV) volumes and function are important in the management of patients with various cardiac abnormalities. Two-dimensional (2D) speckle tracking echocardiography (STE) is shown to be accurate in detecting subclinical myocardial dysfunction when most of the conventional echocardiography parameters were normal. Three-dimensional (3D) echocardiography is a new noninvasive imaging technique that has been shown to be accurate in determining cardiac volume and performance. Establishment of normal range values of 3D STE over a different range of ages is crucial before applying this recent technology in clinical applications. This study aimed to assess feasibility of 3D LV STE and establish normal values for the LV systolic function among healthy Egyptian preschool-age pediatric population using 2D and 3D STE. RESULTS: A total of 200 subjects (95%) met the criteria for 2DSTE analysis, 10 were excluded from the 2D analysis and 180 subjects (85%) met the criteria for 3D STE analysis. Regarding the 2D STE GLS, the mean was -22.1345 ± 2.166%, GCS was f -19.02 ± 1.23%, and GRS was 42.25 ± 2.35%. There was a strongly positive significant correlation between age and 2D values of GLS (P = 0.001). The GCS showed a weakly positive nonsignificant correlation with age (P = 0.28), while GRS showed a strongly negative significant correlation with age (P = 0.001). Regarding the 3D STE data, GLS mean was -20.48 ± 1.526%, GCS mean was -13.90 ± 2.05%, while GRS mean was 47.21 ± 2.382%. 3D GLS values had a strongly positive significant correlation with age (P = 0.001). While GCS showed a weakly positive nonsignificant correlation (P = 0.955), GRS showed a strongly negative significant correlation (P = 0.001). Linear correlation analysis of 2D and 3D values of strain showed that GLS had a strongly positive significant correlation (P = 0.001), while GCS showed a weakly positive nonsignificant correlation (P = 0.161) and GRS showed a strongly positive significant correlation (P = 0.001). Conclusions 3D global strain analysis using the 3D STE is feasible in the preschool-age pediatric population. Results were almost concordant with previous observations in most of the values except for GCS, especially 3D values which could be attributed to different vendor system used and different ethnicity. Further studies are required to reinforce these data using the GE vendor machine. |
format | Online Article Text |
id | pubmed-8960099 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-89600992022-03-29 Assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children Kamel, Heba Elsayegh, Ayah Tarek Nazmi, Hany Attia, Hebatallah Mohamed Egypt Heart J Research BACKGROUND: Accurate measurements of left ventricular (LV) volumes and function are important in the management of patients with various cardiac abnormalities. Two-dimensional (2D) speckle tracking echocardiography (STE) is shown to be accurate in detecting subclinical myocardial dysfunction when most of the conventional echocardiography parameters were normal. Three-dimensional (3D) echocardiography is a new noninvasive imaging technique that has been shown to be accurate in determining cardiac volume and performance. Establishment of normal range values of 3D STE over a different range of ages is crucial before applying this recent technology in clinical applications. This study aimed to assess feasibility of 3D LV STE and establish normal values for the LV systolic function among healthy Egyptian preschool-age pediatric population using 2D and 3D STE. RESULTS: A total of 200 subjects (95%) met the criteria for 2DSTE analysis, 10 were excluded from the 2D analysis and 180 subjects (85%) met the criteria for 3D STE analysis. Regarding the 2D STE GLS, the mean was -22.1345 ± 2.166%, GCS was f -19.02 ± 1.23%, and GRS was 42.25 ± 2.35%. There was a strongly positive significant correlation between age and 2D values of GLS (P = 0.001). The GCS showed a weakly positive nonsignificant correlation with age (P = 0.28), while GRS showed a strongly negative significant correlation with age (P = 0.001). Regarding the 3D STE data, GLS mean was -20.48 ± 1.526%, GCS mean was -13.90 ± 2.05%, while GRS mean was 47.21 ± 2.382%. 3D GLS values had a strongly positive significant correlation with age (P = 0.001). While GCS showed a weakly positive nonsignificant correlation (P = 0.955), GRS showed a strongly negative significant correlation (P = 0.001). Linear correlation analysis of 2D and 3D values of strain showed that GLS had a strongly positive significant correlation (P = 0.001), while GCS showed a weakly positive nonsignificant correlation (P = 0.161) and GRS showed a strongly positive significant correlation (P = 0.001). Conclusions 3D global strain analysis using the 3D STE is feasible in the preschool-age pediatric population. Results were almost concordant with previous observations in most of the values except for GCS, especially 3D values which could be attributed to different vendor system used and different ethnicity. Further studies are required to reinforce these data using the GE vendor machine. Springer Berlin Heidelberg 2022-03-28 /pmc/articles/PMC8960099/ /pubmed/35347471 http://dx.doi.org/10.1186/s43044-022-00258-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Kamel, Heba Elsayegh, Ayah Tarek Nazmi, Hany Attia, Hebatallah Mohamed Assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children |
title | Assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children |
title_full | Assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children |
title_fullStr | Assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children |
title_full_unstemmed | Assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children |
title_short | Assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children |
title_sort | assessment of left ventricular systolic function using two- and three-dimensional speckle tracking echocardiography among healthy preschool-age pediatric children |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8960099/ https://www.ncbi.nlm.nih.gov/pubmed/35347471 http://dx.doi.org/10.1186/s43044-022-00258-w |
work_keys_str_mv | AT kamelheba assessmentofleftventricularsystolicfunctionusingtwoandthreedimensionalspeckletrackingechocardiographyamonghealthypreschoolagepediatricchildren AT elsayeghayahtarek assessmentofleftventricularsystolicfunctionusingtwoandthreedimensionalspeckletrackingechocardiographyamonghealthypreschoolagepediatricchildren AT nazmihany assessmentofleftventricularsystolicfunctionusingtwoandthreedimensionalspeckletrackingechocardiographyamonghealthypreschoolagepediatricchildren AT attiahebatallahmohamed assessmentofleftventricularsystolicfunctionusingtwoandthreedimensionalspeckletrackingechocardiographyamonghealthypreschoolagepediatricchildren |