Cargando…
SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction
In computer vision, reference datasets from simulation and real outdoor scenes have been highly successful in promoting algorithmic development in stereo reconstruction. Endoscopic stereo reconstruction for surgical scenes gives rise to specific problems, including the lack of clear corner features,...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8961000/ https://www.ncbi.nlm.nih.gov/pubmed/34906918 http://dx.doi.org/10.1016/j.media.2021.102302 |
_version_ | 1784677503836618752 |
---|---|
author | Edwards, P.J. Eddie Psychogyios, Dimitris Speidel, Stefanie Maier-Hein, Lena Stoyanov, Danail |
author_facet | Edwards, P.J. Eddie Psychogyios, Dimitris Speidel, Stefanie Maier-Hein, Lena Stoyanov, Danail |
author_sort | Edwards, P.J. Eddie |
collection | PubMed |
description | In computer vision, reference datasets from simulation and real outdoor scenes have been highly successful in promoting algorithmic development in stereo reconstruction. Endoscopic stereo reconstruction for surgical scenes gives rise to specific problems, including the lack of clear corner features, highly specular surface properties and the presence of blood and smoke. These issues present difficulties for both stereo reconstruction itself and also for standardised dataset production. Previous datasets have been produced using computed tomography (CT) or structured light reconstruction on phantom or ex vivo models. We present a stereo-endoscopic reconstruction validation dataset based on cone-beam CT (SERV-CT). Two ex vivo small porcine full torso cadavers were placed within the view of the endoscope with both the endoscope and target anatomy visible in the CT scan. Subsequent orientation of the endoscope was manually aligned to match the stereoscopic view and benchmark disparities, depths and occlusions are calculated. The requirement of a CT scan limited the number of stereo pairs to 8 from each ex vivo sample. For the second sample an RGB surface was acquired to aid alignment of smooth, featureless surfaces. Repeated manual alignments showed an RMS disparity accuracy of around 2 pixels and a depth accuracy of about 2 mm. A simplified reference dataset is provided consisting of endoscope image pairs with corresponding calibration, disparities, depths and occlusions covering the majority of the endoscopic image and a range of tissue types, including smooth specular surfaces, as well as significant variation of depth. We assessed the performance of various stereo algorithms from online available repositories. There is a significant variation between algorithms, highlighting some of the challenges of surgical endoscopic images. The SERV-CT dataset provides an easy to use stereoscopic validation for surgical applications with smooth reference disparities and depths covering the majority of the endoscopic image. This complements existing resources well and we hope will aid the development of surgical endoscopic anatomical reconstruction algorithms. |
format | Online Article Text |
id | pubmed-8961000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-89610002022-04-26 SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction Edwards, P.J. Eddie Psychogyios, Dimitris Speidel, Stefanie Maier-Hein, Lena Stoyanov, Danail Med Image Anal Article In computer vision, reference datasets from simulation and real outdoor scenes have been highly successful in promoting algorithmic development in stereo reconstruction. Endoscopic stereo reconstruction for surgical scenes gives rise to specific problems, including the lack of clear corner features, highly specular surface properties and the presence of blood and smoke. These issues present difficulties for both stereo reconstruction itself and also for standardised dataset production. Previous datasets have been produced using computed tomography (CT) or structured light reconstruction on phantom or ex vivo models. We present a stereo-endoscopic reconstruction validation dataset based on cone-beam CT (SERV-CT). Two ex vivo small porcine full torso cadavers were placed within the view of the endoscope with both the endoscope and target anatomy visible in the CT scan. Subsequent orientation of the endoscope was manually aligned to match the stereoscopic view and benchmark disparities, depths and occlusions are calculated. The requirement of a CT scan limited the number of stereo pairs to 8 from each ex vivo sample. For the second sample an RGB surface was acquired to aid alignment of smooth, featureless surfaces. Repeated manual alignments showed an RMS disparity accuracy of around 2 pixels and a depth accuracy of about 2 mm. A simplified reference dataset is provided consisting of endoscope image pairs with corresponding calibration, disparities, depths and occlusions covering the majority of the endoscopic image and a range of tissue types, including smooth specular surfaces, as well as significant variation of depth. We assessed the performance of various stereo algorithms from online available repositories. There is a significant variation between algorithms, highlighting some of the challenges of surgical endoscopic images. The SERV-CT dataset provides an easy to use stereoscopic validation for surgical applications with smooth reference disparities and depths covering the majority of the endoscopic image. This complements existing resources well and we hope will aid the development of surgical endoscopic anatomical reconstruction algorithms. Elsevier 2022-02 /pmc/articles/PMC8961000/ /pubmed/34906918 http://dx.doi.org/10.1016/j.media.2021.102302 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Edwards, P.J. Eddie Psychogyios, Dimitris Speidel, Stefanie Maier-Hein, Lena Stoyanov, Danail SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction |
title | SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction |
title_full | SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction |
title_fullStr | SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction |
title_full_unstemmed | SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction |
title_short | SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction |
title_sort | serv-ct: a disparity dataset from cone-beam ct for validation of endoscopic 3d reconstruction |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8961000/ https://www.ncbi.nlm.nih.gov/pubmed/34906918 http://dx.doi.org/10.1016/j.media.2021.102302 |
work_keys_str_mv | AT edwardspjeddie servctadisparitydatasetfromconebeamctforvalidationofendoscopic3dreconstruction AT psychogyiosdimitris servctadisparitydatasetfromconebeamctforvalidationofendoscopic3dreconstruction AT speidelstefanie servctadisparitydatasetfromconebeamctforvalidationofendoscopic3dreconstruction AT maierheinlena servctadisparitydatasetfromconebeamctforvalidationofendoscopic3dreconstruction AT stoyanovdanail servctadisparitydatasetfromconebeamctforvalidationofendoscopic3dreconstruction |