Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up

Applying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the physico-chemical properties, histological response and radiographs of four copolym...

Descripción completa

Detalles Bibliográficos
Autores principales: Gareb, Barzi, van Bakelen, Nico B., Driessen, Léon, Buma, Pieter, Kuipers, Jeroen, Grijpma, Dirk W., Vissink, Arjan, Bos, Ruud R.M., van Minnen, Baucke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: KeAi Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8961280/
https://www.ncbi.nlm.nih.gov/pubmed/35386449
http://dx.doi.org/10.1016/j.bioactmat.2022.01.015
_version_ 1784677563054948352
author Gareb, Barzi
van Bakelen, Nico B.
Driessen, Léon
Buma, Pieter
Kuipers, Jeroen
Grijpma, Dirk W.
Vissink, Arjan
Bos, Ruud R.M.
van Minnen, Baucke
author_facet Gareb, Barzi
van Bakelen, Nico B.
Driessen, Léon
Buma, Pieter
Kuipers, Jeroen
Grijpma, Dirk W.
Vissink, Arjan
Bos, Ruud R.M.
van Minnen, Baucke
author_sort Gareb, Barzi
collection PubMed
description Applying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the physico-chemical properties, histological response and radiographs of four copolymeric biodegradable osteosynthesis systems in a goat model with 48-months follow-up. The systems were implanted subperiosteally in both tibia and radius of 12 Dutch White goats. The BioSorb FX [poly(70LLA-co-30DLLA)], Inion CPS [poly([70–78.5]LLA-co-[16–24]DLLA-co-4TMC)], SonicWeld Rx [poly(DLLA)], LactoSorb [poly(82LLA-co-18GA)] systems and a negative control were randomly implanted in each extremity. Samples were assessed at 6-, 12-, 18-, 24-, 36-, and 48-month follow-up. Surface topography was performed using scanning electron microscopy (SEM). Differential scanning calorimetry and gel permeation chromatography were performed on initial and explanted samples. Histological sections were systematically assessed by two blinded researchers using (polarized) light microscopy, SEM and energy-dispersive X-ray analysis. The SonicWeld Rx system was amorphous while the others were semi-crystalline. Foreign-body reactions were not observed during the complete follow-up. The SonicWeld Rx and LactoSorb systems reached bone percentages of negative controls after 18 months while the BioSorb Fx and Inion CPS systems reached these levels after 36 months. The SonicWeld Rx system showed the most predictable degradation profile. All the biodegradable systems were safe to use and well-tolerated (i.e., complete implant replacement by bone, no clinical or histological foreign body reactions, no [sterile] abscess formation, no re-interventions needed), but nanoscale residual polymeric fragments were observed at every system's assessment.
format Online
Article
Text
id pubmed-8961280
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher KeAi Publishing
record_format MEDLINE/PubMed
spelling pubmed-89612802022-04-05 Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up Gareb, Barzi van Bakelen, Nico B. Driessen, Léon Buma, Pieter Kuipers, Jeroen Grijpma, Dirk W. Vissink, Arjan Bos, Ruud R.M. van Minnen, Baucke Bioact Mater Article Applying biodegradable osteosyntheses avoids the disadvantages of titanium osteosyntheses. However, foreign-body reactions remain a major concern and evidence of complete resorption is lacking. This study compared the physico-chemical properties, histological response and radiographs of four copolymeric biodegradable osteosynthesis systems in a goat model with 48-months follow-up. The systems were implanted subperiosteally in both tibia and radius of 12 Dutch White goats. The BioSorb FX [poly(70LLA-co-30DLLA)], Inion CPS [poly([70–78.5]LLA-co-[16–24]DLLA-co-4TMC)], SonicWeld Rx [poly(DLLA)], LactoSorb [poly(82LLA-co-18GA)] systems and a negative control were randomly implanted in each extremity. Samples were assessed at 6-, 12-, 18-, 24-, 36-, and 48-month follow-up. Surface topography was performed using scanning electron microscopy (SEM). Differential scanning calorimetry and gel permeation chromatography were performed on initial and explanted samples. Histological sections were systematically assessed by two blinded researchers using (polarized) light microscopy, SEM and energy-dispersive X-ray analysis. The SonicWeld Rx system was amorphous while the others were semi-crystalline. Foreign-body reactions were not observed during the complete follow-up. The SonicWeld Rx and LactoSorb systems reached bone percentages of negative controls after 18 months while the BioSorb Fx and Inion CPS systems reached these levels after 36 months. The SonicWeld Rx system showed the most predictable degradation profile. All the biodegradable systems were safe to use and well-tolerated (i.e., complete implant replacement by bone, no clinical or histological foreign body reactions, no [sterile] abscess formation, no re-interventions needed), but nanoscale residual polymeric fragments were observed at every system's assessment. KeAi Publishing 2022-01-19 /pmc/articles/PMC8961280/ /pubmed/35386449 http://dx.doi.org/10.1016/j.bioactmat.2022.01.015 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gareb, Barzi
van Bakelen, Nico B.
Driessen, Léon
Buma, Pieter
Kuipers, Jeroen
Grijpma, Dirk W.
Vissink, Arjan
Bos, Ruud R.M.
van Minnen, Baucke
Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up
title Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up
title_full Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up
title_fullStr Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up
title_full_unstemmed Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up
title_short Biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: A goat model with four years follow-up
title_sort biocompatibility and degradation comparisons of four biodegradable copolymeric osteosynthesis systems used in maxillofacial surgery: a goat model with four years follow-up
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8961280/
https://www.ncbi.nlm.nih.gov/pubmed/35386449
http://dx.doi.org/10.1016/j.bioactmat.2022.01.015
work_keys_str_mv AT garebbarzi biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup
AT vanbakelennicob biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup
AT driessenleon biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup
AT bumapieter biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup
AT kuipersjeroen biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup
AT grijpmadirkw biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup
AT vissinkarjan biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup
AT bosruudrm biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup
AT vanminnenbaucke biocompatibilityanddegradationcomparisonsoffourbiodegradablecopolymericosteosynthesissystemsusedinmaxillofacialsurgeryagoatmodelwithfouryearsfollowup