Cargando…
Evaluation of a continuously active disinfectant for decontamination of portable medical equipment
A single spray application of a continuously active disinfectant on portable equipment resulted in significant reductions in aerobic colony counts over 7 days and in recovery of Staphylococcus aureus and enterococci: 3 of 93 cultures (3%) versus 11 of 97 (11%) and 20 of 97 (21%) in quaternary ammoni...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cambridge University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8961336/ https://www.ncbi.nlm.nih.gov/pubmed/34034834 http://dx.doi.org/10.1017/ice.2021.66 |
_version_ | 1784677576118108160 |
---|---|
author | Redmond, Sarah N. Cadnum, Jennifer L. Silva, Sandra Y. Pearlmutter, Basya S. Jencson, Annette L. Alhmidi, Heba Wilson, Brigid M. Donskey, Curtis J. |
author_facet | Redmond, Sarah N. Cadnum, Jennifer L. Silva, Sandra Y. Pearlmutter, Basya S. Jencson, Annette L. Alhmidi, Heba Wilson, Brigid M. Donskey, Curtis J. |
author_sort | Redmond, Sarah N. |
collection | PubMed |
description | A single spray application of a continuously active disinfectant on portable equipment resulted in significant reductions in aerobic colony counts over 7 days and in recovery of Staphylococcus aureus and enterococci: 3 of 93 cultures (3%) versus 11 of 97 (11%) and 20 of 97 (21%) in quaternary ammonium disinfectant and untreated control groups, respectively. |
format | Online Article Text |
id | pubmed-8961336 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Cambridge University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-89613362022-04-08 Evaluation of a continuously active disinfectant for decontamination of portable medical equipment Redmond, Sarah N. Cadnum, Jennifer L. Silva, Sandra Y. Pearlmutter, Basya S. Jencson, Annette L. Alhmidi, Heba Wilson, Brigid M. Donskey, Curtis J. Infect Control Hosp Epidemiol Concise Communication A single spray application of a continuously active disinfectant on portable equipment resulted in significant reductions in aerobic colony counts over 7 days and in recovery of Staphylococcus aureus and enterococci: 3 of 93 cultures (3%) versus 11 of 97 (11%) and 20 of 97 (21%) in quaternary ammonium disinfectant and untreated control groups, respectively. Cambridge University Press 2022-03 2021-05-26 /pmc/articles/PMC8961336/ /pubmed/34034834 http://dx.doi.org/10.1017/ice.2021.66 Text en © The Society for Healthcare Epidemiology of America 2021 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Concise Communication Redmond, Sarah N. Cadnum, Jennifer L. Silva, Sandra Y. Pearlmutter, Basya S. Jencson, Annette L. Alhmidi, Heba Wilson, Brigid M. Donskey, Curtis J. Evaluation of a continuously active disinfectant for decontamination of portable medical equipment |
title | Evaluation of a continuously active disinfectant for decontamination of portable medical equipment |
title_full | Evaluation of a continuously active disinfectant for decontamination of portable medical equipment |
title_fullStr | Evaluation of a continuously active disinfectant for decontamination of portable medical equipment |
title_full_unstemmed | Evaluation of a continuously active disinfectant for decontamination of portable medical equipment |
title_short | Evaluation of a continuously active disinfectant for decontamination of portable medical equipment |
title_sort | evaluation of a continuously active disinfectant for decontamination of portable medical equipment |
topic | Concise Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8961336/ https://www.ncbi.nlm.nih.gov/pubmed/34034834 http://dx.doi.org/10.1017/ice.2021.66 |
work_keys_str_mv | AT redmondsarahn evaluationofacontinuouslyactivedisinfectantfordecontaminationofportablemedicalequipment AT cadnumjenniferl evaluationofacontinuouslyactivedisinfectantfordecontaminationofportablemedicalequipment AT silvasandray evaluationofacontinuouslyactivedisinfectantfordecontaminationofportablemedicalequipment AT pearlmutterbasyas evaluationofacontinuouslyactivedisinfectantfordecontaminationofportablemedicalequipment AT jencsonannettel evaluationofacontinuouslyactivedisinfectantfordecontaminationofportablemedicalequipment AT alhmidiheba evaluationofacontinuouslyactivedisinfectantfordecontaminationofportablemedicalequipment AT wilsonbrigidm evaluationofacontinuouslyactivedisinfectantfordecontaminationofportablemedicalequipment AT donskeycurtisj evaluationofacontinuouslyactivedisinfectantfordecontaminationofportablemedicalequipment |