Cargando…
A prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk
OBJECTIVE: Our aim was to assess diagnostic accuracy in the prediction of small for gestational age (SGA <10th centile) and fetal growth restricted (FGR) (SGA <3rd centile) fetuses using three different sonographic methods in pregnancies at increased risk of fetal growth restriction: 1) fetal...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8962129/ https://www.ncbi.nlm.nih.gov/pubmed/35346088 http://dx.doi.org/10.1186/s12884-022-04545-x |
_version_ | 1784677731481419776 |
---|---|
author | Visentin, Silvia Londero, Ambrogio P. Cataneo, Ilaria Bellussi, Federica Salsi, Ginevra Pilu, Gianluigi Cosmi, Erich |
author_facet | Visentin, Silvia Londero, Ambrogio P. Cataneo, Ilaria Bellussi, Federica Salsi, Ginevra Pilu, Gianluigi Cosmi, Erich |
author_sort | Visentin, Silvia |
collection | PubMed |
description | OBJECTIVE: Our aim was to assess diagnostic accuracy in the prediction of small for gestational age (SGA <10th centile) and fetal growth restricted (FGR) (SGA <3rd centile) fetuses using three different sonographic methods in pregnancies at increased risk of fetal growth restriction: 1) fetal abdominal circumference (AC) z-scores, 2) estimated fetal weight (EFW) z-scores according to postnatal reference standard; 3) EFW z-scores according to a prenatal reference standard. METHODS: Singleton pregnancies at increased risk of fetal growth restriction seen in two university hospitals between 2014 and 2015 were studied retrospectively. EFW was calculated using formulas proposed by the INTERGROWTH-21st project and Hadlock; data derived from publications by the INTEGROWTH-twenty-first century project and Hadlock were used to calculate z-scores (AC and EFW). The accuracy of different methods was calculated and compared. RESULTS: The study group included 406 patients. Prenatal standard EFW z-scores derived from INTERGROWTH-21st project and Hadlock and co-workers performed similarly and were more accurate in identifying SGA infants than using AC z-scores or a postnatal reference standard. The subgroups analysis demonstrated that EFW prenatal standard was more or similarly accurate compared to other methods across all subgroups, defined by gestational age and birth weight. CONCLUSIONS: Prenatal standard EFW z-scores derived from either INTERGROWTH-21 st project or Hadlock and co-workers publications demonstrated a statistically significant advantage over other biometric methods in the diagnosis of SGA fetuses. |
format | Online Article Text |
id | pubmed-8962129 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-89621292022-03-30 A prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk Visentin, Silvia Londero, Ambrogio P. Cataneo, Ilaria Bellussi, Federica Salsi, Ginevra Pilu, Gianluigi Cosmi, Erich BMC Pregnancy Childbirth Research OBJECTIVE: Our aim was to assess diagnostic accuracy in the prediction of small for gestational age (SGA <10th centile) and fetal growth restricted (FGR) (SGA <3rd centile) fetuses using three different sonographic methods in pregnancies at increased risk of fetal growth restriction: 1) fetal abdominal circumference (AC) z-scores, 2) estimated fetal weight (EFW) z-scores according to postnatal reference standard; 3) EFW z-scores according to a prenatal reference standard. METHODS: Singleton pregnancies at increased risk of fetal growth restriction seen in two university hospitals between 2014 and 2015 were studied retrospectively. EFW was calculated using formulas proposed by the INTERGROWTH-21st project and Hadlock; data derived from publications by the INTEGROWTH-twenty-first century project and Hadlock were used to calculate z-scores (AC and EFW). The accuracy of different methods was calculated and compared. RESULTS: The study group included 406 patients. Prenatal standard EFW z-scores derived from INTERGROWTH-21st project and Hadlock and co-workers performed similarly and were more accurate in identifying SGA infants than using AC z-scores or a postnatal reference standard. The subgroups analysis demonstrated that EFW prenatal standard was more or similarly accurate compared to other methods across all subgroups, defined by gestational age and birth weight. CONCLUSIONS: Prenatal standard EFW z-scores derived from either INTERGROWTH-21 st project or Hadlock and co-workers publications demonstrated a statistically significant advantage over other biometric methods in the diagnosis of SGA fetuses. BioMed Central 2022-03-26 /pmc/articles/PMC8962129/ /pubmed/35346088 http://dx.doi.org/10.1186/s12884-022-04545-x Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Visentin, Silvia Londero, Ambrogio P. Cataneo, Ilaria Bellussi, Federica Salsi, Ginevra Pilu, Gianluigi Cosmi, Erich A prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk |
title | A prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk |
title_full | A prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk |
title_fullStr | A prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk |
title_full_unstemmed | A prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk |
title_short | A prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk |
title_sort | prenatal standard for fetal weight improves the prenatal diagnosis of small for gestational age fetuses in pregnancies at increased risk |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8962129/ https://www.ncbi.nlm.nih.gov/pubmed/35346088 http://dx.doi.org/10.1186/s12884-022-04545-x |
work_keys_str_mv | AT visentinsilvia aprenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT londeroambrogiop aprenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT cataneoilaria aprenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT bellussifederica aprenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT salsiginevra aprenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT pilugianluigi aprenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT cosmierich aprenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT visentinsilvia prenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT londeroambrogiop prenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT cataneoilaria prenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT bellussifederica prenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT salsiginevra prenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT pilugianluigi prenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk AT cosmierich prenatalstandardforfetalweightimprovestheprenataldiagnosisofsmallforgestationalagefetusesinpregnanciesatincreasedrisk |