Cargando…

Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2

BACKGROUND: Laser peripheral iridotomy (LPI) is effective in primary angle-closure suspects (PACS); however, predictors for anterior segment alterations after LPI are limited. We aimed to evaluate the anterior segment biometric parameters before and after LPI in PACS using the recently developed, CA...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Xiaoxiao, Wang, Xiaolei, Tang, Yizhen, Sun, Xinghuai, Chen, Yuhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8962180/
https://www.ncbi.nlm.nih.gov/pubmed/35351034
http://dx.doi.org/10.1186/s12886-022-02366-2
_version_ 1784677742009122816
author Chen, Xiaoxiao
Wang, Xiaolei
Tang, Yizhen
Sun, Xinghuai
Chen, Yuhong
author_facet Chen, Xiaoxiao
Wang, Xiaolei
Tang, Yizhen
Sun, Xinghuai
Chen, Yuhong
author_sort Chen, Xiaoxiao
collection PubMed
description BACKGROUND: Laser peripheral iridotomy (LPI) is effective in primary angle-closure suspects (PACS); however, predictors for anterior segment alterations after LPI are limited. We aimed to evaluate the anterior segment biometric parameters before and after LPI in PACS using the recently developed, CASIA 2 device of anterior segment optical coherence tomography (AS-OCT). METHODS: We performed LPI in 52 PACS. Anterior segment parameters, including anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber volume (ACV), iris curvature (ICURVE), iridotrabecular contact (ITC), lens vault (LV), lens thickness (LT), radius of the lens, angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular iris angle (TIA) at different distances (i.e., 500 μm from the sclera spur), were evaluated before and after LPI using CASIA 2. RESULTS: Eyes of PACS after LPI had a greater ACV, AOD, ARA, TISA, and TIA, and a lower ITC and ICURVE (all p < 0.001) than those before LPI. On a 360° scan, the anterior chamber angle in the superior quadrant increased the most after the LPI. A higher baseline LT was significantly associated with a greater postoperative increase in AOD 500, ARA 500, TISA 500, and TIA 500 (p = 0.001, p = 0.010, p = 0.004, and p < 0.001, respectively). CONCLUSIONS: We found that LPI widens the anterior chamber angle in the PACS, especially, in the superior quadrant around the iridotomy hole. Eyes with a thicker lens are more likely to experience angle opening because of the LPI.
format Online
Article
Text
id pubmed-8962180
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-89621802022-03-30 Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2 Chen, Xiaoxiao Wang, Xiaolei Tang, Yizhen Sun, Xinghuai Chen, Yuhong BMC Ophthalmol Research BACKGROUND: Laser peripheral iridotomy (LPI) is effective in primary angle-closure suspects (PACS); however, predictors for anterior segment alterations after LPI are limited. We aimed to evaluate the anterior segment biometric parameters before and after LPI in PACS using the recently developed, CASIA 2 device of anterior segment optical coherence tomography (AS-OCT). METHODS: We performed LPI in 52 PACS. Anterior segment parameters, including anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber volume (ACV), iris curvature (ICURVE), iridotrabecular contact (ITC), lens vault (LV), lens thickness (LT), radius of the lens, angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular iris angle (TIA) at different distances (i.e., 500 μm from the sclera spur), were evaluated before and after LPI using CASIA 2. RESULTS: Eyes of PACS after LPI had a greater ACV, AOD, ARA, TISA, and TIA, and a lower ITC and ICURVE (all p < 0.001) than those before LPI. On a 360° scan, the anterior chamber angle in the superior quadrant increased the most after the LPI. A higher baseline LT was significantly associated with a greater postoperative increase in AOD 500, ARA 500, TISA 500, and TIA 500 (p = 0.001, p = 0.010, p = 0.004, and p < 0.001, respectively). CONCLUSIONS: We found that LPI widens the anterior chamber angle in the PACS, especially, in the superior quadrant around the iridotomy hole. Eyes with a thicker lens are more likely to experience angle opening because of the LPI. BioMed Central 2022-03-28 /pmc/articles/PMC8962180/ /pubmed/35351034 http://dx.doi.org/10.1186/s12886-022-02366-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Chen, Xiaoxiao
Wang, Xiaolei
Tang, Yizhen
Sun, Xinghuai
Chen, Yuhong
Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2
title Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2
title_full Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2
title_fullStr Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2
title_full_unstemmed Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2
title_short Optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using CASIA2
title_sort optical coherence tomography analysis of anterior segment parameters before and after laser peripheral iridotomy in primary angle-closure suspects by using casia2
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8962180/
https://www.ncbi.nlm.nih.gov/pubmed/35351034
http://dx.doi.org/10.1186/s12886-022-02366-2
work_keys_str_mv AT chenxiaoxiao opticalcoherencetomographyanalysisofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomyinprimaryangleclosuresuspectsbyusingcasia2
AT wangxiaolei opticalcoherencetomographyanalysisofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomyinprimaryangleclosuresuspectsbyusingcasia2
AT tangyizhen opticalcoherencetomographyanalysisofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomyinprimaryangleclosuresuspectsbyusingcasia2
AT sunxinghuai opticalcoherencetomographyanalysisofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomyinprimaryangleclosuresuspectsbyusingcasia2
AT chenyuhong opticalcoherencetomographyanalysisofanteriorsegmentparametersbeforeandafterlaserperipheraliridotomyinprimaryangleclosuresuspectsbyusingcasia2