A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination

Fetal acidosis is one of the main concerns during labor. Currently, fetal blood sampling (FBS) has become the most accurate measurement of acidosis detection. However, it is invasive and does not provide a real time measurement due to laboratory procedures. Delays in diagnosis of acidosis have cause...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdul Halim, Siti Fatimah, Zakaria, Zulkarnay, Pusppanathan, Jaysuman, Mohd Noor, Anas, Norali, Ahmad Nasrul, Fazalul Rahiman, Mohd Hafiz, Mohd Muji, Siti Zarina, Abdul Rahim, Ruzairi, Engku-Husna, Engku Ismail, Ali Hassan, Muhamad Khairul, Aziz Safar, Muhammad Juhairi, Salleh, Ahmad Faizal, Mat Som, Mohd Hanafi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8963069/
https://www.ncbi.nlm.nih.gov/pubmed/35214235
http://dx.doi.org/10.3390/s22041334
_version_ 1784677914307985408
author Abdul Halim, Siti Fatimah
Zakaria, Zulkarnay
Pusppanathan, Jaysuman
Mohd Noor, Anas
Norali, Ahmad Nasrul
Fazalul Rahiman, Mohd Hafiz
Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Engku-Husna, Engku Ismail
Ali Hassan, Muhamad Khairul
Aziz Safar, Muhammad Juhairi
Salleh, Ahmad Faizal
Mat Som, Mohd Hanafi
author_facet Abdul Halim, Siti Fatimah
Zakaria, Zulkarnay
Pusppanathan, Jaysuman
Mohd Noor, Anas
Norali, Ahmad Nasrul
Fazalul Rahiman, Mohd Hafiz
Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Engku-Husna, Engku Ismail
Ali Hassan, Muhamad Khairul
Aziz Safar, Muhammad Juhairi
Salleh, Ahmad Faizal
Mat Som, Mohd Hanafi
author_sort Abdul Halim, Siti Fatimah
collection PubMed
description Fetal acidosis is one of the main concerns during labor. Currently, fetal blood sampling (FBS) has become the most accurate measurement of acidosis detection. However, it is invasive and does not provide a real time measurement due to laboratory procedures. Delays in diagnosis of acidosis have caused serious injury to the fetus, especially for the brain and the heart. This paper reviews the new technique in diagnosis of acidosis non-invasively. Magnetic Induction Spectroscopy (MIS) has been proposed to be a new device for acidosis detection in recent years. This paper explains the basic principle of MIS and outlines the design specifications and design considerations for a MIS pH probe. It is expected that readers will gain a basic understanding of the development of a MIS pH probe from this review.
format Online
Article
Text
id pubmed-8963069
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89630692022-03-30 A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination Abdul Halim, Siti Fatimah Zakaria, Zulkarnay Pusppanathan, Jaysuman Mohd Noor, Anas Norali, Ahmad Nasrul Fazalul Rahiman, Mohd Hafiz Mohd Muji, Siti Zarina Abdul Rahim, Ruzairi Engku-Husna, Engku Ismail Ali Hassan, Muhamad Khairul Aziz Safar, Muhammad Juhairi Salleh, Ahmad Faizal Mat Som, Mohd Hanafi Sensors (Basel) Review Fetal acidosis is one of the main concerns during labor. Currently, fetal blood sampling (FBS) has become the most accurate measurement of acidosis detection. However, it is invasive and does not provide a real time measurement due to laboratory procedures. Delays in diagnosis of acidosis have caused serious injury to the fetus, especially for the brain and the heart. This paper reviews the new technique in diagnosis of acidosis non-invasively. Magnetic Induction Spectroscopy (MIS) has been proposed to be a new device for acidosis detection in recent years. This paper explains the basic principle of MIS and outlines the design specifications and design considerations for a MIS pH probe. It is expected that readers will gain a basic understanding of the development of a MIS pH probe from this review. MDPI 2022-02-10 /pmc/articles/PMC8963069/ /pubmed/35214235 http://dx.doi.org/10.3390/s22041334 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Abdul Halim, Siti Fatimah
Zakaria, Zulkarnay
Pusppanathan, Jaysuman
Mohd Noor, Anas
Norali, Ahmad Nasrul
Fazalul Rahiman, Mohd Hafiz
Mohd Muji, Siti Zarina
Abdul Rahim, Ruzairi
Engku-Husna, Engku Ismail
Ali Hassan, Muhamad Khairul
Aziz Safar, Muhammad Juhairi
Salleh, Ahmad Faizal
Mat Som, Mohd Hanafi
A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination
title A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination
title_full A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination
title_fullStr A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination
title_full_unstemmed A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination
title_short A Review on Magnetic Induction Spectroscopy Potential for Fetal Acidosis Examination
title_sort review on magnetic induction spectroscopy potential for fetal acidosis examination
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8963069/
https://www.ncbi.nlm.nih.gov/pubmed/35214235
http://dx.doi.org/10.3390/s22041334
work_keys_str_mv AT abdulhalimsitifatimah areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT zakariazulkarnay areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT pusppanathanjaysuman areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT mohdnooranas areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT noraliahmadnasrul areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT fazalulrahimanmohdhafiz areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT mohdmujisitizarina areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT abdulrahimruzairi areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT engkuhusnaengkuismail areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT alihassanmuhamadkhairul areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT azizsafarmuhammadjuhairi areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT sallehahmadfaizal areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT matsommohdhanafi areviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT abdulhalimsitifatimah reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT zakariazulkarnay reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT pusppanathanjaysuman reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT mohdnooranas reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT noraliahmadnasrul reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT fazalulrahimanmohdhafiz reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT mohdmujisitizarina reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT abdulrahimruzairi reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT engkuhusnaengkuismail reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT alihassanmuhamadkhairul reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT azizsafarmuhammadjuhairi reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT sallehahmadfaizal reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination
AT matsommohdhanafi reviewonmagneticinductionspectroscopypotentialforfetalacidosisexamination