Cargando…

Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity

The purpose of this study was to investigate dose evaluation depending on dose range using optically stimulated luminescence dosimeter (OSLD) and evaluate the possibility of high dose evaluation. This study investigated a commercial OSLD and used a Co-60 gamma irradiator for irradiation. The OSLDs (...

Descripción completa

Detalles Bibliográficos
Autor principal: Han, Su Chul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8963533/
https://www.ncbi.nlm.nih.gov/pubmed/35349607
http://dx.doi.org/10.1371/journal.pone.0266110
_version_ 1784678008361058304
author Han, Su Chul
author_facet Han, Su Chul
author_sort Han, Su Chul
collection PubMed
description The purpose of this study was to investigate dose evaluation depending on dose range using optically stimulated luminescence dosimeter (OSLD) and evaluate the possibility of high dose evaluation. This study investigated a commercial OSLD and used a Co-60 gamma irradiator for irradiation. The OSLDs (N = 26) were sampled in total OSLDs (N = 46) depending on the radiation sensitivity for this study. After irradiating doses from 0.5 to 40 Gy at fixed intervals in a standard environment, the dose response of a reference OSLD (N = 5) was determined through the reading process at each dose. The dose-response curves obtained from the reference OSLD were fitted according to the dose. In the dose range below 3 Gy, a linear function was used to determine the relationship between dose and the OSLD response. Quadratic and cubic functions were applied for dose ranges of up to 15 Gy and 40 Gy, respectively. Test OSLDs (N = 21) were evaluated at various doses (2.5 to 30 Gy) using different fitting functions, according to dose ranges. When doses from 0.5 Gy to 3.0 Gy were curve-fitted to the linear function, the relationship was y = 70278.0x − 3125.3 (r(2) = 0.999). When doses of up to 15 Gy were curve-fitted to the quadratic function, the relationship was y = 628.6x(2) + 70444.6x − 6142.3 (r(2) = 0.999). Furthermore, when doses of up to 40 Gy were curve-fitted to the cubic function, the relation was y = −15.5x(3) + 527.3x(2) + 75059.6x − 16260.3 (r(2) = 0.998). Test OSLDs were evaluated for various dose ranges based on the above equation. It was confirmed that the average difference was 0.86 ± 0.27%, and it was evaluated that the largest difference occurred at 30 Gy (2.24 ± 0.24%). In this study, we prove that measurements using the OSLD at various dose ranges, including high doses, will be possible through the application of an in-house software program and a correction process.
format Online
Article
Text
id pubmed-8963533
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-89635332022-03-30 Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity Han, Su Chul PLoS One Research Article The purpose of this study was to investigate dose evaluation depending on dose range using optically stimulated luminescence dosimeter (OSLD) and evaluate the possibility of high dose evaluation. This study investigated a commercial OSLD and used a Co-60 gamma irradiator for irradiation. The OSLDs (N = 26) were sampled in total OSLDs (N = 46) depending on the radiation sensitivity for this study. After irradiating doses from 0.5 to 40 Gy at fixed intervals in a standard environment, the dose response of a reference OSLD (N = 5) was determined through the reading process at each dose. The dose-response curves obtained from the reference OSLD were fitted according to the dose. In the dose range below 3 Gy, a linear function was used to determine the relationship between dose and the OSLD response. Quadratic and cubic functions were applied for dose ranges of up to 15 Gy and 40 Gy, respectively. Test OSLDs (N = 21) were evaluated at various doses (2.5 to 30 Gy) using different fitting functions, according to dose ranges. When doses from 0.5 Gy to 3.0 Gy were curve-fitted to the linear function, the relationship was y = 70278.0x − 3125.3 (r(2) = 0.999). When doses of up to 15 Gy were curve-fitted to the quadratic function, the relationship was y = 628.6x(2) + 70444.6x − 6142.3 (r(2) = 0.999). Furthermore, when doses of up to 40 Gy were curve-fitted to the cubic function, the relation was y = −15.5x(3) + 527.3x(2) + 75059.6x − 16260.3 (r(2) = 0.998). Test OSLDs were evaluated for various dose ranges based on the above equation. It was confirmed that the average difference was 0.86 ± 0.27%, and it was evaluated that the largest difference occurred at 30 Gy (2.24 ± 0.24%). In this study, we prove that measurements using the OSLD at various dose ranges, including high doses, will be possible through the application of an in-house software program and a correction process. Public Library of Science 2022-03-29 /pmc/articles/PMC8963533/ /pubmed/35349607 http://dx.doi.org/10.1371/journal.pone.0266110 Text en © 2022 Su Chul Han https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Han, Su Chul
Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity
title Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity
title_full Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity
title_fullStr Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity
title_full_unstemmed Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity
title_short Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity
title_sort preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8963533/
https://www.ncbi.nlm.nih.gov/pubmed/35349607
http://dx.doi.org/10.1371/journal.pone.0266110
work_keys_str_mv AT hansuchul preliminarystudyfordoseevaluationdependingondoserangewithopticallystimulatedluminescencedosimeterconsideringindividualdosimetersensitivity