Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity
The purpose of this study was to investigate dose evaluation depending on dose range using optically stimulated luminescence dosimeter (OSLD) and evaluate the possibility of high dose evaluation. This study investigated a commercial OSLD and used a Co-60 gamma irradiator for irradiation. The OSLDs (...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8963533/ https://www.ncbi.nlm.nih.gov/pubmed/35349607 http://dx.doi.org/10.1371/journal.pone.0266110 |
_version_ | 1784678008361058304 |
---|---|
author | Han, Su Chul |
author_facet | Han, Su Chul |
author_sort | Han, Su Chul |
collection | PubMed |
description | The purpose of this study was to investigate dose evaluation depending on dose range using optically stimulated luminescence dosimeter (OSLD) and evaluate the possibility of high dose evaluation. This study investigated a commercial OSLD and used a Co-60 gamma irradiator for irradiation. The OSLDs (N = 26) were sampled in total OSLDs (N = 46) depending on the radiation sensitivity for this study. After irradiating doses from 0.5 to 40 Gy at fixed intervals in a standard environment, the dose response of a reference OSLD (N = 5) was determined through the reading process at each dose. The dose-response curves obtained from the reference OSLD were fitted according to the dose. In the dose range below 3 Gy, a linear function was used to determine the relationship between dose and the OSLD response. Quadratic and cubic functions were applied for dose ranges of up to 15 Gy and 40 Gy, respectively. Test OSLDs (N = 21) were evaluated at various doses (2.5 to 30 Gy) using different fitting functions, according to dose ranges. When doses from 0.5 Gy to 3.0 Gy were curve-fitted to the linear function, the relationship was y = 70278.0x − 3125.3 (r(2) = 0.999). When doses of up to 15 Gy were curve-fitted to the quadratic function, the relationship was y = 628.6x(2) + 70444.6x − 6142.3 (r(2) = 0.999). Furthermore, when doses of up to 40 Gy were curve-fitted to the cubic function, the relation was y = −15.5x(3) + 527.3x(2) + 75059.6x − 16260.3 (r(2) = 0.998). Test OSLDs were evaluated for various dose ranges based on the above equation. It was confirmed that the average difference was 0.86 ± 0.27%, and it was evaluated that the largest difference occurred at 30 Gy (2.24 ± 0.24%). In this study, we prove that measurements using the OSLD at various dose ranges, including high doses, will be possible through the application of an in-house software program and a correction process. |
format | Online Article Text |
id | pubmed-8963533 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-89635332022-03-30 Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity Han, Su Chul PLoS One Research Article The purpose of this study was to investigate dose evaluation depending on dose range using optically stimulated luminescence dosimeter (OSLD) and evaluate the possibility of high dose evaluation. This study investigated a commercial OSLD and used a Co-60 gamma irradiator for irradiation. The OSLDs (N = 26) were sampled in total OSLDs (N = 46) depending on the radiation sensitivity for this study. After irradiating doses from 0.5 to 40 Gy at fixed intervals in a standard environment, the dose response of a reference OSLD (N = 5) was determined through the reading process at each dose. The dose-response curves obtained from the reference OSLD were fitted according to the dose. In the dose range below 3 Gy, a linear function was used to determine the relationship between dose and the OSLD response. Quadratic and cubic functions were applied for dose ranges of up to 15 Gy and 40 Gy, respectively. Test OSLDs (N = 21) were evaluated at various doses (2.5 to 30 Gy) using different fitting functions, according to dose ranges. When doses from 0.5 Gy to 3.0 Gy were curve-fitted to the linear function, the relationship was y = 70278.0x − 3125.3 (r(2) = 0.999). When doses of up to 15 Gy were curve-fitted to the quadratic function, the relationship was y = 628.6x(2) + 70444.6x − 6142.3 (r(2) = 0.999). Furthermore, when doses of up to 40 Gy were curve-fitted to the cubic function, the relation was y = −15.5x(3) + 527.3x(2) + 75059.6x − 16260.3 (r(2) = 0.998). Test OSLDs were evaluated for various dose ranges based on the above equation. It was confirmed that the average difference was 0.86 ± 0.27%, and it was evaluated that the largest difference occurred at 30 Gy (2.24 ± 0.24%). In this study, we prove that measurements using the OSLD at various dose ranges, including high doses, will be possible through the application of an in-house software program and a correction process. Public Library of Science 2022-03-29 /pmc/articles/PMC8963533/ /pubmed/35349607 http://dx.doi.org/10.1371/journal.pone.0266110 Text en © 2022 Su Chul Han https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Han, Su Chul Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity |
title | Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity |
title_full | Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity |
title_fullStr | Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity |
title_full_unstemmed | Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity |
title_short | Preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity |
title_sort | preliminary study for dose evaluation depending on dose range with optically stimulated luminescence dosimeter considering individual dosimeter sensitivity |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8963533/ https://www.ncbi.nlm.nih.gov/pubmed/35349607 http://dx.doi.org/10.1371/journal.pone.0266110 |
work_keys_str_mv | AT hansuchul preliminarystudyfordoseevaluationdependingondoserangewithopticallystimulatedluminescencedosimeterconsideringindividualdosimetersensitivity |