Proximal femoral replacement for non-neoplastic conditions: a systematic review on current outcomes

Proximal femoral replacement (PFR) is a well-established treatment for neoplasia of the proximal femur. The use of this surgical technique for non-neoplastic conditions has increased over the years. We carried out a systematic review of the literature to study the indications, complications, and fun...

Descripción completa

Detalles Bibliográficos
Autores principales: Di Martino, Alberto, Pederiva, Davide, Bordini, Barbara, Di Carlo, Gabriele, Panciera, Alessandro, Geraci, Giuseppe, Stefanini, Niccolò, Faldini, Cesare
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8964877/
https://www.ncbi.nlm.nih.gov/pubmed/35348913
http://dx.doi.org/10.1186/s10195-022-00632-z
Descripción
Sumario:Proximal femoral replacement (PFR) is a well-established treatment for neoplasia of the proximal femur. The use of this surgical technique for non-neoplastic conditions has increased over the years. We carried out a systematic review of the literature to study the indications, complications, and functional results when PFR is used for non-neoplastic conditions. Twenty-seven studies were included in the review with a total of 828 PFRs with a mean follow-up of 50 months (range 1–225 months). The main indications were infection (28%), periprosthetic fracture (27%), aseptic loosening (22%), and fracture (16%). The rate of reoperation was 20.3% overall. The overall revision rate was 15.4%. The main complications were dislocation (10.2%) and infection (7.3%). After 2010, the rates of reoperation (25.5% versus 18.2%), loosening (9.4% versus 3.2%), and dislocation (15.7% versus 7.9%) were lower than before 2010. The 30-day mortality ranged from 0% to 9%. The hip function scores improved post-surgery. In conclusion, the use of PFR in non-neoplastic conditions remains a marginal tool, associated with low direct mortality and high complication rates, but we expect its use to increase in the near future.