1-Year Outcomes of a Multicenter Randomized Controlled Trial of the Ankura II Thoracic Endoprosthesis for the Endovascular Treatment of Stanford Type B Aortic Dissections
BACKGROUND: The Ankura II Thoracic Stent Graft System (Lifetech, Shenzhen, China) is an evolution of the Ankura stent graft. This study reports one-year outcomes of the Ankura II Thoracic Stent Graft System for endovascular treatment of Stanford type B aortic dissections. METHODS: The Ankura II Thor...
Autores principales: | Shu, Chang, He, Hao, Fu, Weiguo, Guo, Wei, Li, Ming, Xi, Erping, Guo, Shuguang, Chen, Xueming, Xiao, Zhanxiang, Yu, Shiqiang, Huang, Jianhua, Dai, Xiangchen, Wang, Zhiwei, Li, Wei, Zheng, Qingshan, Li, Quanming, Wang, Lunchang, Li, Xin, Wang, Junwei, Gu, Feng |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8964940/ https://www.ncbi.nlm.nih.gov/pubmed/35369315 http://dx.doi.org/10.3389/fcvm.2022.805585 |
Ejemplares similares
-
Endovascular treatment of infrarenal aortic aneurysm using the ANKURA stent graft – one-center case series
por: Nowakowski, Przemysław, et al.
Publicado: (2023) -
Endovascular repair for retrograde type A intramural hematoma with focal intimal disruption in descending aorta
por: Li, Jiehua, et al.
Publicado: (2021) -
Self-Radiopaque Markers Guiding Physician-Modified Fenestration (S-Fenestration) in Aortic Arch Endovascular Repair
por: Li, Xin, et al.
Publicado: (2021) -
Funnel technique for wide infrarenal aneurysm neck with Lifetech Ankura™ Stent Graft System
por: İşcan, Hakkı Zafer, et al.
Publicado: (2021) -
Application of thoracic endovascular aortic repair (TEVAR) in treating dwarfism with Stanford B aortic dissection: A case report
por: Qiu, Jian, et al.
Publicado: (2018)