Cargando…
Exploring the Coordination of Cardiac Ion Channels With Action Potential Clamp Technique
The patch clamp technique underwent continual advancement and developed numerous variants in cardiac electrophysiology since its introduction in the late 1970s. In the beginning, the capability of the technique was limited to recording one single current from one cell stimulated with a rectangular c...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8966222/ https://www.ncbi.nlm.nih.gov/pubmed/35370800 http://dx.doi.org/10.3389/fphys.2022.864002 |
_version_ | 1784678608108781568 |
---|---|
author | Horváth, Balázs Szentandrássy, Norbert Dienes, Csaba Kovács, Zsigmond M. Nánási, Péter P. Chen-Izu, Ye Izu, Leighton T. Banyasz, Tamas |
author_facet | Horváth, Balázs Szentandrássy, Norbert Dienes, Csaba Kovács, Zsigmond M. Nánási, Péter P. Chen-Izu, Ye Izu, Leighton T. Banyasz, Tamas |
author_sort | Horváth, Balázs |
collection | PubMed |
description | The patch clamp technique underwent continual advancement and developed numerous variants in cardiac electrophysiology since its introduction in the late 1970s. In the beginning, the capability of the technique was limited to recording one single current from one cell stimulated with a rectangular command pulse. Since that time, the technique has been extended to record multiple currents under various command pulses including action potential. The current review summarizes the development of the patch clamp technique in cardiac electrophysiology with special focus on the potential applications in integrative physiology. |
format | Online Article Text |
id | pubmed-8966222 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-89662222022-03-31 Exploring the Coordination of Cardiac Ion Channels With Action Potential Clamp Technique Horváth, Balázs Szentandrássy, Norbert Dienes, Csaba Kovács, Zsigmond M. Nánási, Péter P. Chen-Izu, Ye Izu, Leighton T. Banyasz, Tamas Front Physiol Physiology The patch clamp technique underwent continual advancement and developed numerous variants in cardiac electrophysiology since its introduction in the late 1970s. In the beginning, the capability of the technique was limited to recording one single current from one cell stimulated with a rectangular command pulse. Since that time, the technique has been extended to record multiple currents under various command pulses including action potential. The current review summarizes the development of the patch clamp technique in cardiac electrophysiology with special focus on the potential applications in integrative physiology. Frontiers Media S.A. 2022-03-16 /pmc/articles/PMC8966222/ /pubmed/35370800 http://dx.doi.org/10.3389/fphys.2022.864002 Text en Copyright © 2022 Horváth, Szentandrássy, Dienes, Kovács, Nánási, Chen-Izu, Izu and Banyasz. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Horváth, Balázs Szentandrássy, Norbert Dienes, Csaba Kovács, Zsigmond M. Nánási, Péter P. Chen-Izu, Ye Izu, Leighton T. Banyasz, Tamas Exploring the Coordination of Cardiac Ion Channels With Action Potential Clamp Technique |
title | Exploring the Coordination of Cardiac Ion Channels With Action Potential Clamp Technique |
title_full | Exploring the Coordination of Cardiac Ion Channels With Action Potential Clamp Technique |
title_fullStr | Exploring the Coordination of Cardiac Ion Channels With Action Potential Clamp Technique |
title_full_unstemmed | Exploring the Coordination of Cardiac Ion Channels With Action Potential Clamp Technique |
title_short | Exploring the Coordination of Cardiac Ion Channels With Action Potential Clamp Technique |
title_sort | exploring the coordination of cardiac ion channels with action potential clamp technique |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8966222/ https://www.ncbi.nlm.nih.gov/pubmed/35370800 http://dx.doi.org/10.3389/fphys.2022.864002 |
work_keys_str_mv | AT horvathbalazs exploringthecoordinationofcardiacionchannelswithactionpotentialclamptechnique AT szentandrassynorbert exploringthecoordinationofcardiacionchannelswithactionpotentialclamptechnique AT dienescsaba exploringthecoordinationofcardiacionchannelswithactionpotentialclamptechnique AT kovacszsigmondm exploringthecoordinationofcardiacionchannelswithactionpotentialclamptechnique AT nanasipeterp exploringthecoordinationofcardiacionchannelswithactionpotentialclamptechnique AT chenizuye exploringthecoordinationofcardiacionchannelswithactionpotentialclamptechnique AT izuleightont exploringthecoordinationofcardiacionchannelswithactionpotentialclamptechnique AT banyasztamas exploringthecoordinationofcardiacionchannelswithactionpotentialclamptechnique |