Cargando…

Arthroplasty of the Knee: Current Techniques for Implant Alignment

When a total knee arthroplasty (TKA) is implanted using the traditional mechanical alignment technique, this typically results in a straight leg, independently of pre-operative or even pre-arthrotic varus or valgus alignment. With mechanical alignment, we distinguish between 2 different alignment te...

Descripción completa

Detalles Bibliográficos
Autores principales: Weber, Patrick, Gollwitzer, Hans
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8967431/
https://www.ncbi.nlm.nih.gov/pubmed/33647995
http://dx.doi.org/10.1055/a-1304-3854
_version_ 1784678838016409600
author Weber, Patrick
Gollwitzer, Hans
author_facet Weber, Patrick
Gollwitzer, Hans
author_sort Weber, Patrick
collection PubMed
description When a total knee arthroplasty (TKA) is implanted using the traditional mechanical alignment technique, this typically results in a straight leg, independently of pre-operative or even pre-arthrotic varus or valgus alignment. With mechanical alignment, we distinguish between 2 different alignment techniques: ligament balancing and bony referencing according to bony skeletal landmarks. In ligament balanced technique beside the straight mechanical axis, the prosthesis is implanted at 90° to the latter. The rotational alignment of the femur is set according to the ligament tension. In the skeletal referenced technique, the rotation of the femur is also set according to bony skeletal landmarks. As a variation of this technique, the prosthesis can be implanted with anatomical alignment. In this technique, the medial slope of the joint line of 3° in the frontal plane is respected during the implantation of TKA. Both techniques result in comparable long-term results with survival rates of almost 80% after 25 years. On the other hand, 15 – 20% of TKA patients report dissatisfaction with their clinical result. For more than 10 years now, the kinematic TKA alignment concept has been developed with the goal to achieve implantation that is adapted to the individual anatomy of the patient. The advocates of this technique expect better function of TKA. This strategy aims to reconstruct the pre-arthrotic anatomy of a given patient while preserving the existing joint line and the mechanical axis without performing ligamentary release. Studies have shown that the function of the prothesis is at least that good as in the conventional techniques. Long-term results are still sparse, but initial studies show that TKA implanted using the kinematic alignment technique exhibit comparable 10-year-survival rates to those implanted using the traditional mechanical alignment technique. Future studies need to show the limitations of this new technique and to identify patients who will or will not significantly benefit from this technique.
format Online
Article
Text
id pubmed-8967431
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-89674312022-04-01 Arthroplasty of the Knee: Current Techniques for Implant Alignment Weber, Patrick Gollwitzer, Hans Z Orthop Unfall When a total knee arthroplasty (TKA) is implanted using the traditional mechanical alignment technique, this typically results in a straight leg, independently of pre-operative or even pre-arthrotic varus or valgus alignment. With mechanical alignment, we distinguish between 2 different alignment techniques: ligament balancing and bony referencing according to bony skeletal landmarks. In ligament balanced technique beside the straight mechanical axis, the prosthesis is implanted at 90° to the latter. The rotational alignment of the femur is set according to the ligament tension. In the skeletal referenced technique, the rotation of the femur is also set according to bony skeletal landmarks. As a variation of this technique, the prosthesis can be implanted with anatomical alignment. In this technique, the medial slope of the joint line of 3° in the frontal plane is respected during the implantation of TKA. Both techniques result in comparable long-term results with survival rates of almost 80% after 25 years. On the other hand, 15 – 20% of TKA patients report dissatisfaction with their clinical result. For more than 10 years now, the kinematic TKA alignment concept has been developed with the goal to achieve implantation that is adapted to the individual anatomy of the patient. The advocates of this technique expect better function of TKA. This strategy aims to reconstruct the pre-arthrotic anatomy of a given patient while preserving the existing joint line and the mechanical axis without performing ligamentary release. Studies have shown that the function of the prothesis is at least that good as in the conventional techniques. Long-term results are still sparse, but initial studies show that TKA implanted using the kinematic alignment technique exhibit comparable 10-year-survival rates to those implanted using the traditional mechanical alignment technique. Future studies need to show the limitations of this new technique and to identify patients who will or will not significantly benefit from this technique. Georg Thieme Verlag KG 2021-03-01 /pmc/articles/PMC8967431/ /pubmed/33647995 http://dx.doi.org/10.1055/a-1304-3854 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Weber, Patrick
Gollwitzer, Hans
Arthroplasty of the Knee: Current Techniques for Implant Alignment
title Arthroplasty of the Knee: Current Techniques for Implant Alignment
title_full Arthroplasty of the Knee: Current Techniques for Implant Alignment
title_fullStr Arthroplasty of the Knee: Current Techniques for Implant Alignment
title_full_unstemmed Arthroplasty of the Knee: Current Techniques for Implant Alignment
title_short Arthroplasty of the Knee: Current Techniques for Implant Alignment
title_sort arthroplasty of the knee: current techniques for implant alignment
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8967431/
https://www.ncbi.nlm.nih.gov/pubmed/33647995
http://dx.doi.org/10.1055/a-1304-3854
work_keys_str_mv AT weberpatrick arthroplastyofthekneecurrenttechniquesforimplantalignment
AT gollwitzerhans arthroplastyofthekneecurrenttechniquesforimplantalignment