Cargando…
Effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells
This study focuses on the contact regions among neighboring nanoparticles in polymer graphene nanocomposites by the extension of nanosheets. The resistance of graphene and the contact zones represent the total resistance of the prolonged nanosheets. Furthermore, the graphene size, interphase depth,...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8967928/ https://www.ncbi.nlm.nih.gov/pubmed/35354877 http://dx.doi.org/10.1038/s41598-022-09398-0 |
_version_ | 1784678934246326272 |
---|---|
author | Zare, Yasser Rhee, Kyong Yop |
author_facet | Zare, Yasser Rhee, Kyong Yop |
author_sort | Zare, Yasser |
collection | PubMed |
description | This study focuses on the contact regions among neighboring nanoparticles in polymer graphene nanocomposites by the extension of nanosheets. The resistance of graphene and the contact zones represent the total resistance of the prolonged nanosheets. Furthermore, the graphene size, interphase depth, and tunneling distance express the effective volume portion of graphene, while the onset of percolation affects the fraction of percolated nanosheets. Finally, a model is developed to investigate the conductivity of the samples using the graphene size, interphase depth, and tunneling size. In addition to the roles played by certain factors in conductivity, the experimental conductivity data for several samples confirm the conductivity predictions. Generally, the polymer sheet in tunnels determines the total resistance of the extended nanosheets because graphene ordinarily exhibits negligible resistance. In addition, a large tunnel positively accelerates the onset of percolation, but increases the tunneling resistance and attenuates the conductivity of the nanocomposite. Further, a thicker interphase and lower percolation threshold promote the conductivity of the system. The developed model can be applied to optimize the biosensors detecting the breast cancer cells. |
format | Online Article Text |
id | pubmed-8967928 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-89679282022-04-01 Effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells Zare, Yasser Rhee, Kyong Yop Sci Rep Article This study focuses on the contact regions among neighboring nanoparticles in polymer graphene nanocomposites by the extension of nanosheets. The resistance of graphene and the contact zones represent the total resistance of the prolonged nanosheets. Furthermore, the graphene size, interphase depth, and tunneling distance express the effective volume portion of graphene, while the onset of percolation affects the fraction of percolated nanosheets. Finally, a model is developed to investigate the conductivity of the samples using the graphene size, interphase depth, and tunneling size. In addition to the roles played by certain factors in conductivity, the experimental conductivity data for several samples confirm the conductivity predictions. Generally, the polymer sheet in tunnels determines the total resistance of the extended nanosheets because graphene ordinarily exhibits negligible resistance. In addition, a large tunnel positively accelerates the onset of percolation, but increases the tunneling resistance and attenuates the conductivity of the nanocomposite. Further, a thicker interphase and lower percolation threshold promote the conductivity of the system. The developed model can be applied to optimize the biosensors detecting the breast cancer cells. Nature Publishing Group UK 2022-03-30 /pmc/articles/PMC8967928/ /pubmed/35354877 http://dx.doi.org/10.1038/s41598-022-09398-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Zare, Yasser Rhee, Kyong Yop Effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells |
title | Effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells |
title_full | Effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells |
title_fullStr | Effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells |
title_full_unstemmed | Effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells |
title_short | Effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells |
title_sort | effect of contact resistance on the electrical conductivity of polymer graphene nanocomposites to optimize the biosensors detecting breast cancer cells |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8967928/ https://www.ncbi.nlm.nih.gov/pubmed/35354877 http://dx.doi.org/10.1038/s41598-022-09398-0 |
work_keys_str_mv | AT zareyasser effectofcontactresistanceontheelectricalconductivityofpolymergraphenenanocompositestooptimizethebiosensorsdetectingbreastcancercells AT rheekyongyop effectofcontactresistanceontheelectricalconductivityofpolymergraphenenanocompositestooptimizethebiosensorsdetectingbreastcancercells |