Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic
The outbreak of novel COVID-19 has severely and unprecedentedly affected millions of people across the globe. The painful respiratory distress caused during this disease calls for external assistance to the victims in the form of ventilation. The most common types of artificial ventilating units ava...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8968386/ https://www.ncbi.nlm.nih.gov/pubmed/35368917 http://dx.doi.org/10.1155/2022/6436818 |
_version_ | 1784679035343732736 |
---|---|
author | Kshetry, Rohan Lal Gupta, Arnab Chattopadhyaya, Somnath Srivastava, Madhulika Sharma, Shubham Singh, Jujhar Gupta, Anirban Das Rajkumar, S. |
author_facet | Kshetry, Rohan Lal Gupta, Arnab Chattopadhyaya, Somnath Srivastava, Madhulika Sharma, Shubham Singh, Jujhar Gupta, Anirban Das Rajkumar, S. |
author_sort | Kshetry, Rohan Lal |
collection | PubMed |
description | The outbreak of novel COVID-19 has severely and unprecedentedly affected millions of people across the globe. The painful respiratory distress caused during this disease calls for external assistance to the victims in the form of ventilation. The most common types of artificial ventilating units available at the healthcare facilities and hospitals are exorbitantly expensive to manufacture, and their number is fairly inadequate even in the so-called developed countries to cater to the burning needs of an ever-increasing number of ailing human subjects. According to available reports, without the provision of ventilation, the novel COVID-19 patients are succumbing to their ailments in a huge number of cases. This colossal problem of the availability of ventilator units can be addressed to a great extent by readily producible and cost-effective ventilating units that can be used on those suffering patients during an acute emergency and in the absence of conventional expensive ventilators at hospitals and medical care units. This paper has made an attempt to design and simulate a simple, yet effective, mechanized ventilator unit, which can be conveniently assembled without a profuse skillset and operated to resuscitate an ailing human patient. The stepper motor-controlled kinematic linkage is designed to deliver the patient with a necessitated discharge of air at optimum oxygen saturation through the AMBU bag connected in a ventilation circuit. With the associated code on MATLAB, the motor control parameters such as angular displacement and speed are deduced according to the input patient conditions (age group, tidal volume, breathing rate, etc.) and thereafter fed to the controller that drives the stepper motor. With a proposed feedback loop, the real-time static and dynamic compliance, airway resistance values can be approximately determined from the pressure variation cycle and fed to the controller unit to adjust the tidal volume as and when necessary. The simplistic yet robust design not only renders easy manufacturability by conventional and rapid prototyping techniques like 3D printing at different scales but also makes the product easily portable with minimal handling difficulty. Keeping the motto of Health for All as envisioned by the WHO, this low-cost indigenously engineered ventilator will definitely help the poor and afflicted towards their right to health and will help the medical professionals buy some time to manage the patient with acute respiratory distress syndrome (ARDS) towards recovery. Moreover, this instrument mostly includes readily available functional units having standard specifications and can be considered as standard bought-out items. |
format | Online Article Text |
id | pubmed-8968386 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-89683862022-04-01 Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic Kshetry, Rohan Lal Gupta, Arnab Chattopadhyaya, Somnath Srivastava, Madhulika Sharma, Shubham Singh, Jujhar Gupta, Anirban Das Rajkumar, S. J Healthc Eng Research Article The outbreak of novel COVID-19 has severely and unprecedentedly affected millions of people across the globe. The painful respiratory distress caused during this disease calls for external assistance to the victims in the form of ventilation. The most common types of artificial ventilating units available at the healthcare facilities and hospitals are exorbitantly expensive to manufacture, and their number is fairly inadequate even in the so-called developed countries to cater to the burning needs of an ever-increasing number of ailing human subjects. According to available reports, without the provision of ventilation, the novel COVID-19 patients are succumbing to their ailments in a huge number of cases. This colossal problem of the availability of ventilator units can be addressed to a great extent by readily producible and cost-effective ventilating units that can be used on those suffering patients during an acute emergency and in the absence of conventional expensive ventilators at hospitals and medical care units. This paper has made an attempt to design and simulate a simple, yet effective, mechanized ventilator unit, which can be conveniently assembled without a profuse skillset and operated to resuscitate an ailing human patient. The stepper motor-controlled kinematic linkage is designed to deliver the patient with a necessitated discharge of air at optimum oxygen saturation through the AMBU bag connected in a ventilation circuit. With the associated code on MATLAB, the motor control parameters such as angular displacement and speed are deduced according to the input patient conditions (age group, tidal volume, breathing rate, etc.) and thereafter fed to the controller that drives the stepper motor. With a proposed feedback loop, the real-time static and dynamic compliance, airway resistance values can be approximately determined from the pressure variation cycle and fed to the controller unit to adjust the tidal volume as and when necessary. The simplistic yet robust design not only renders easy manufacturability by conventional and rapid prototyping techniques like 3D printing at different scales but also makes the product easily portable with minimal handling difficulty. Keeping the motto of Health for All as envisioned by the WHO, this low-cost indigenously engineered ventilator will definitely help the poor and afflicted towards their right to health and will help the medical professionals buy some time to manage the patient with acute respiratory distress syndrome (ARDS) towards recovery. Moreover, this instrument mostly includes readily available functional units having standard specifications and can be considered as standard bought-out items. Hindawi 2022-03-30 /pmc/articles/PMC8968386/ /pubmed/35368917 http://dx.doi.org/10.1155/2022/6436818 Text en Copyright © 2022 Rohan Lal Kshetry et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Kshetry, Rohan Lal Gupta, Arnab Chattopadhyaya, Somnath Srivastava, Madhulika Sharma, Shubham Singh, Jujhar Gupta, Anirban Das Rajkumar, S. Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic |
title | Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic |
title_full | Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic |
title_fullStr | Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic |
title_full_unstemmed | Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic |
title_short | Design and Analysis of a Low-Cost Electronically Controlled Mobile Ventilator, Incorporating Mechanized AMBU Bag, for Patients during COVID-19 Pandemic |
title_sort | design and analysis of a low-cost electronically controlled mobile ventilator, incorporating mechanized ambu bag, for patients during covid-19 pandemic |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8968386/ https://www.ncbi.nlm.nih.gov/pubmed/35368917 http://dx.doi.org/10.1155/2022/6436818 |
work_keys_str_mv | AT kshetryrohanlal designandanalysisofalowcostelectronicallycontrolledmobileventilatorincorporatingmechanizedambubagforpatientsduringcovid19pandemic AT guptaarnab designandanalysisofalowcostelectronicallycontrolledmobileventilatorincorporatingmechanizedambubagforpatientsduringcovid19pandemic AT chattopadhyayasomnath designandanalysisofalowcostelectronicallycontrolledmobileventilatorincorporatingmechanizedambubagforpatientsduringcovid19pandemic AT srivastavamadhulika designandanalysisofalowcostelectronicallycontrolledmobileventilatorincorporatingmechanizedambubagforpatientsduringcovid19pandemic AT sharmashubham designandanalysisofalowcostelectronicallycontrolledmobileventilatorincorporatingmechanizedambubagforpatientsduringcovid19pandemic AT singhjujhar designandanalysisofalowcostelectronicallycontrolledmobileventilatorincorporatingmechanizedambubagforpatientsduringcovid19pandemic AT guptaanirbandas designandanalysisofalowcostelectronicallycontrolledmobileventilatorincorporatingmechanizedambubagforpatientsduringcovid19pandemic AT rajkumars designandanalysisofalowcostelectronicallycontrolledmobileventilatorincorporatingmechanizedambubagforpatientsduringcovid19pandemic |