Cargando…

Cadaveric Examination of the Radiographic Safe Zone for Open Reduction and Internal Fixation of the Calcaneus Posterior Facet

BACKGROUND: The purpose of this study is to define a safe zone for screw placement on a lateral radiograph of the calcaneus taking into account the lateral to medial convexity of the posterior facet. Such findings may serve to improve surgical quality during open reduction and internal fixation (ORI...

Descripción completa

Detalles Bibliográficos
Autores principales: Brand, Jordan, Elaydi, Ali, Moran, Jay, Yoo, Brad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8969522/
https://www.ncbi.nlm.nih.gov/pubmed/35372747
http://dx.doi.org/10.1177/24730114221088838
_version_ 1784679266652258304
author Brand, Jordan
Elaydi, Ali
Moran, Jay
Yoo, Brad
author_facet Brand, Jordan
Elaydi, Ali
Moran, Jay
Yoo, Brad
author_sort Brand, Jordan
collection PubMed
description BACKGROUND: The purpose of this study is to define a safe zone for screw placement on a lateral radiograph of the calcaneus taking into account the lateral to medial convexity of the posterior facet. Such findings may serve to improve surgical quality during open reduction and internal fixation (ORIF) of the posterior facet of the calcaneus. METHODS: Eleven cadaveric calcanei were harvested and the articular margins of the posterior facet were outlined with a radiopaque wire. Lateral radiographs, similar to those used for intraoperative fluoroscopy, of each specimen were obtained and calibrated to a standardized marker. The proximal-to-distal length of the posterior facet was then divided into quadrants. The greatest height difference between the superolateral and inferomedial surfaces outlined by the radiopaque marker were measured in the 2 most posterior quadrants, as screw insertion in this area would be mostly likely to risk screw penetration during ORIF. RESULTS: The average distance from the osseous surface to the radiographic marker was 3.3 ± 1.2 mm in the most posterior quadrant (fourth quadrant) and 3.2 ± 1.6 mm in the quadrant just anterior to this (third quadrant). The range for unsafe screw placement was 1.7 to 5.6 mm below the osseous surface in the fourth quadrant and 1.1 to 6.6 mm in the third quadrant. CONCLUSION: Intraoperative radiographic assessment of the safety of subchondral posterior facet screws does not correlate to its osteology. Because of the superolateral to inferomedial convexity of the posterior facet of the calcaneus, overly long screws may appear to be radiographically intraosseous, though in actuality the screw may be intra-articular. On average, screws placed in the fourth quadrant of the facet are at less risk if 3.3 mm inferior to the upper margin of the osseous shadow on fluoroscopic imaging and 3.2 mm inferior in the third quadrant. Though limited by a small sample size, this study sets a foundation for future research into this complex osteology. LEVEL OF EVIDENCE: Level V, mechanism-based reasoning.
format Online
Article
Text
id pubmed-8969522
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-89695222022-04-01 Cadaveric Examination of the Radiographic Safe Zone for Open Reduction and Internal Fixation of the Calcaneus Posterior Facet Brand, Jordan Elaydi, Ali Moran, Jay Yoo, Brad Foot Ankle Orthop Article BACKGROUND: The purpose of this study is to define a safe zone for screw placement on a lateral radiograph of the calcaneus taking into account the lateral to medial convexity of the posterior facet. Such findings may serve to improve surgical quality during open reduction and internal fixation (ORIF) of the posterior facet of the calcaneus. METHODS: Eleven cadaveric calcanei were harvested and the articular margins of the posterior facet were outlined with a radiopaque wire. Lateral radiographs, similar to those used for intraoperative fluoroscopy, of each specimen were obtained and calibrated to a standardized marker. The proximal-to-distal length of the posterior facet was then divided into quadrants. The greatest height difference between the superolateral and inferomedial surfaces outlined by the radiopaque marker were measured in the 2 most posterior quadrants, as screw insertion in this area would be mostly likely to risk screw penetration during ORIF. RESULTS: The average distance from the osseous surface to the radiographic marker was 3.3 ± 1.2 mm in the most posterior quadrant (fourth quadrant) and 3.2 ± 1.6 mm in the quadrant just anterior to this (third quadrant). The range for unsafe screw placement was 1.7 to 5.6 mm below the osseous surface in the fourth quadrant and 1.1 to 6.6 mm in the third quadrant. CONCLUSION: Intraoperative radiographic assessment of the safety of subchondral posterior facet screws does not correlate to its osteology. Because of the superolateral to inferomedial convexity of the posterior facet of the calcaneus, overly long screws may appear to be radiographically intraosseous, though in actuality the screw may be intra-articular. On average, screws placed in the fourth quadrant of the facet are at less risk if 3.3 mm inferior to the upper margin of the osseous shadow on fluoroscopic imaging and 3.2 mm inferior in the third quadrant. Though limited by a small sample size, this study sets a foundation for future research into this complex osteology. LEVEL OF EVIDENCE: Level V, mechanism-based reasoning. SAGE Publications 2022-03-28 /pmc/articles/PMC8969522/ /pubmed/35372747 http://dx.doi.org/10.1177/24730114221088838 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Brand, Jordan
Elaydi, Ali
Moran, Jay
Yoo, Brad
Cadaveric Examination of the Radiographic Safe Zone for Open Reduction and Internal Fixation of the Calcaneus Posterior Facet
title Cadaveric Examination of the Radiographic Safe Zone for Open Reduction and Internal Fixation of the Calcaneus Posterior Facet
title_full Cadaveric Examination of the Radiographic Safe Zone for Open Reduction and Internal Fixation of the Calcaneus Posterior Facet
title_fullStr Cadaveric Examination of the Radiographic Safe Zone for Open Reduction and Internal Fixation of the Calcaneus Posterior Facet
title_full_unstemmed Cadaveric Examination of the Radiographic Safe Zone for Open Reduction and Internal Fixation of the Calcaneus Posterior Facet
title_short Cadaveric Examination of the Radiographic Safe Zone for Open Reduction and Internal Fixation of the Calcaneus Posterior Facet
title_sort cadaveric examination of the radiographic safe zone for open reduction and internal fixation of the calcaneus posterior facet
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8969522/
https://www.ncbi.nlm.nih.gov/pubmed/35372747
http://dx.doi.org/10.1177/24730114221088838
work_keys_str_mv AT brandjordan cadavericexaminationoftheradiographicsafezoneforopenreductionandinternalfixationofthecalcaneusposteriorfacet
AT elaydiali cadavericexaminationoftheradiographicsafezoneforopenreductionandinternalfixationofthecalcaneusposteriorfacet
AT moranjay cadavericexaminationoftheradiographicsafezoneforopenreductionandinternalfixationofthecalcaneusposteriorfacet
AT yoobrad cadavericexaminationoftheradiographicsafezoneforopenreductionandinternalfixationofthecalcaneusposteriorfacet