<Editors’ Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction

We propose two methods to evaluate system-related distortion in magnetic resonance imaging (MRI) in radiation therapy treatment planning (RTP) and demonstrate the importance of three-dimensional (3D) distortion correction (DC) by quantitatively measuring the distortion magnitude. First, a small pin...

Descripción completa

Detalles Bibliográficos
Autores principales: Kato, Yutaka, Okudaira, Kuniyasu, Kamomae, Takeshi, Kumagai, Motoki, Nagai, Youta, Taoka, Toshiaki, Itoh, Yoshiyuki, Naganawa, Shinji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nagoya University 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8971027/
https://www.ncbi.nlm.nih.gov/pubmed/35391999
http://dx.doi.org/10.18999/nagjms.84.1.29
_version_ 1784679557004001280
author Kato, Yutaka
Okudaira, Kuniyasu
Kamomae, Takeshi
Kumagai, Motoki
Nagai, Youta
Taoka, Toshiaki
Itoh, Yoshiyuki
Naganawa, Shinji
author_facet Kato, Yutaka
Okudaira, Kuniyasu
Kamomae, Takeshi
Kumagai, Motoki
Nagai, Youta
Taoka, Toshiaki
Itoh, Yoshiyuki
Naganawa, Shinji
author_sort Kato, Yutaka
collection PubMed
description We propose two methods to evaluate system-related distortion in magnetic resonance imaging (MRI) in radiation therapy treatment planning (RTP) and demonstrate the importance of three-dimensional (3D) distortion correction (DC) by quantitatively measuring the distortion magnitude. First, a small pin phantom was scanned at multiple positions using an external laser guide for accurate phantom placement and combined into one image encompassing a large area. Direct plane images were used for evaluating in-plane distortion and multiplanar reconstruction images for through-plane distortion with no DC, two-dimensional (2D) DC, and 3D DC. Second, a large grid sheet was scanned as the direct plane of the phantom placement. The distortion magnitude was determined by measuring the displacement between the MRI and reference coordinates. The measured distortions were compared between in- and through-plane when applying DC and between the two methods. The small pin phantom method can be used to evaluate a wide range of distortions, whereas data from the entire plane can be obtained with a single scan using the grid sheet without a laser guide. The mean distortion magnitudes differed between the methods. Furthermore, the 3D DC reduced in- and through-plane distortions. In conclusion, the small pin phantom method can be used to evaluate a wide range of distortions by creating a combined image, whereas the grid sheet method is simpler, accurate, repeatable, and does not require a special-order phantom or laser guide. As 3D DC reduces both in- and through-plane distortions, it can be used to improve RTP quality.
format Online
Article
Text
id pubmed-8971027
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nagoya University
record_format MEDLINE/PubMed
spelling pubmed-89710272022-04-06 <Editors’ Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction Kato, Yutaka Okudaira, Kuniyasu Kamomae, Takeshi Kumagai, Motoki Nagai, Youta Taoka, Toshiaki Itoh, Yoshiyuki Naganawa, Shinji Nagoya J Med Sci Original Paper We propose two methods to evaluate system-related distortion in magnetic resonance imaging (MRI) in radiation therapy treatment planning (RTP) and demonstrate the importance of three-dimensional (3D) distortion correction (DC) by quantitatively measuring the distortion magnitude. First, a small pin phantom was scanned at multiple positions using an external laser guide for accurate phantom placement and combined into one image encompassing a large area. Direct plane images were used for evaluating in-plane distortion and multiplanar reconstruction images for through-plane distortion with no DC, two-dimensional (2D) DC, and 3D DC. Second, a large grid sheet was scanned as the direct plane of the phantom placement. The distortion magnitude was determined by measuring the displacement between the MRI and reference coordinates. The measured distortions were compared between in- and through-plane when applying DC and between the two methods. The small pin phantom method can be used to evaluate a wide range of distortions, whereas data from the entire plane can be obtained with a single scan using the grid sheet without a laser guide. The mean distortion magnitudes differed between the methods. Furthermore, the 3D DC reduced in- and through-plane distortions. In conclusion, the small pin phantom method can be used to evaluate a wide range of distortions by creating a combined image, whereas the grid sheet method is simpler, accurate, repeatable, and does not require a special-order phantom or laser guide. As 3D DC reduces both in- and through-plane distortions, it can be used to improve RTP quality. Nagoya University 2022-02 /pmc/articles/PMC8971027/ /pubmed/35391999 http://dx.doi.org/10.18999/nagjms.84.1.29 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ).
spellingShingle Original Paper
Kato, Yutaka
Okudaira, Kuniyasu
Kamomae, Takeshi
Kumagai, Motoki
Nagai, Youta
Taoka, Toshiaki
Itoh, Yoshiyuki
Naganawa, Shinji
<Editors’ Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
title <Editors’ Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
title_full <Editors’ Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
title_fullStr <Editors’ Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
title_full_unstemmed <Editors’ Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
title_short <Editors’ Choice> Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
title_sort <editors’ choice> evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8971027/
https://www.ncbi.nlm.nih.gov/pubmed/35391999
http://dx.doi.org/10.18999/nagjms.84.1.29
work_keys_str_mv AT katoyutaka editorschoiceevaluationofsystemrelatedmagneticresonanceimaginggeometricdistortioninradiationtherapytreatmentplanningtwoapproachesandeffectivenessofthreedimensionaldistortioncorrection
AT okudairakuniyasu editorschoiceevaluationofsystemrelatedmagneticresonanceimaginggeometricdistortioninradiationtherapytreatmentplanningtwoapproachesandeffectivenessofthreedimensionaldistortioncorrection
AT kamomaetakeshi editorschoiceevaluationofsystemrelatedmagneticresonanceimaginggeometricdistortioninradiationtherapytreatmentplanningtwoapproachesandeffectivenessofthreedimensionaldistortioncorrection
AT kumagaimotoki editorschoiceevaluationofsystemrelatedmagneticresonanceimaginggeometricdistortioninradiationtherapytreatmentplanningtwoapproachesandeffectivenessofthreedimensionaldistortioncorrection
AT nagaiyouta editorschoiceevaluationofsystemrelatedmagneticresonanceimaginggeometricdistortioninradiationtherapytreatmentplanningtwoapproachesandeffectivenessofthreedimensionaldistortioncorrection
AT taokatoshiaki editorschoiceevaluationofsystemrelatedmagneticresonanceimaginggeometricdistortioninradiationtherapytreatmentplanningtwoapproachesandeffectivenessofthreedimensionaldistortioncorrection
AT itohyoshiyuki editorschoiceevaluationofsystemrelatedmagneticresonanceimaginggeometricdistortioninradiationtherapytreatmentplanningtwoapproachesandeffectivenessofthreedimensionaldistortioncorrection
AT naganawashinji editorschoiceevaluationofsystemrelatedmagneticresonanceimaginggeometricdistortioninradiationtherapytreatmentplanningtwoapproachesandeffectivenessofthreedimensionaldistortioncorrection