Cargando…

Left ventricular assist device implants in patients on extracorporeal membrane oxygenation: do we need cardiopulmonary bypass?

OBJECTIVES: Implanting a durable left ventricular assist device (LVAD) in a patient on extracorporeal life support (ECLS) is challenging. The goal of this study was to compare the results of patients from a European registry who had a durable LVAD implanted with or without transition from ECLS to ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Pappalardo, Federico, Potapov, Evgenij, Loforte, Antonio, Morshuis, Michiel, Schibilsky, David, Zimpfer, Daniel, Riebandt, Julia, Etz, Christian, Attisani, Matteo, Rinaldi, Mauro, Haneya, Assad, Ramjankhan, Faiz, Donker, Dirk, Jorde, Ulrich P, Lewin, Daniel, Wieloch, Radi, Ayala, Rafael, Cremer, Jochen, Bertoldi, Letizia, Borger, Michael, Lichtenberg, Artur, Gummert, Jan, Saeed, Diyar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8972226/
https://www.ncbi.nlm.nih.gov/pubmed/34788423
http://dx.doi.org/10.1093/icvts/ivab311
Descripción
Sumario:OBJECTIVES: Implanting a durable left ventricular assist device (LVAD) in a patient on extracorporeal life support (ECLS) is challenging. The goal of this study was to compare the results of patients from a European registry who had a durable LVAD implanted with or without transition from ECLS to cardiopulmonary bypass (CPB). METHODS: A total of 531 patients on ECLS support who had an LVAD implant between January 2010 and August 2018 were analysed; after 1:1 propensity score matching, we identified and compared 175 patients in each group. RESULTS: The duration of preoperative ECLS was 7 [standard deviation (SD) 6] vs 7 (SD 6) days in patients with or without CPB (P = 0.984). The surgical time was longer in the CPB group [285 (SD 72) vs 209 [SD 75] min; P ≤ 0.001). The postoperative chest tube output was comparable [1513 (SD 1311) vs 1390 (SD 1121) ml; P = 0.3]. However, re-exploration for bleeding was necessary in 41% vs 29% of patients with or without CPB (P = 0.01) and a significantly higher number of packed red blood cells and fresh frozen plasma [8 (SD 8) vs 6 (SD 4) units; P = 0.001 and 6 (SD 7) vs 5 (SD 5) units; P = 0.03] were administered to patients operated on with CPB. A postoperative mechanical right ventricular support device was necessary in 50% vs 41% of patients (P = 0.08). The stroke rate was not significantly different (P 0.99). No difference in survival was observed. CONCLUSIONS: Omitting CPB for an LVAD implant in patients on ECLS is safe and results in shorter operating time, less re-exploration for bleeding and fewer blood products. However, no survival benefit is observed.