Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy

BACKGROUND: Prostate alignment is subject to interobserver variability in cone-beam CT (CBCT)-based soft-tissue matching. This study aims to analyze the impact of possible interobserver variability in CBCT-based soft-tissue matching for prostate cancer radiotherapy. METHODS: Retrospective data, cons...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xiangbin, Wang, Xin, Li, Xiaoyu, Zhou, Li, Nie, Shihong, Li, Changhu, Wang, Xuetao, Dai, Guyu, Deng, Zhonghua, Zhong, Renming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8973574/
https://www.ncbi.nlm.nih.gov/pubmed/35365155
http://dx.doi.org/10.1186/s13014-022-02034-1
_version_ 1784680066418999296
author Zhang, Xiangbin
Wang, Xin
Li, Xiaoyu
Zhou, Li
Nie, Shihong
Li, Changhu
Wang, Xuetao
Dai, Guyu
Deng, Zhonghua
Zhong, Renming
author_facet Zhang, Xiangbin
Wang, Xin
Li, Xiaoyu
Zhou, Li
Nie, Shihong
Li, Changhu
Wang, Xuetao
Dai, Guyu
Deng, Zhonghua
Zhong, Renming
author_sort Zhang, Xiangbin
collection PubMed
description BACKGROUND: Prostate alignment is subject to interobserver variability in cone-beam CT (CBCT)-based soft-tissue matching. This study aims to analyze the impact of possible interobserver variability in CBCT-based soft-tissue matching for prostate cancer radiotherapy. METHODS: Retrospective data, consisting of 156 CBCT images from twelve prostate cancer patients with elective nodal irradiation were analyzed in this study. To simulate possible interobserver variability, couch shifts of 2 mm relative to the resulting patient position of prostate alignment were assumed as potential patient positions (27 possibilities). For each CBCT, the doses of the potential patient positions were re-calculated using deformable image registration-based synthetic CT. The impact of the simulated interobserver variability was evaluated using tumor control probabilities (TCPs) and normal tissue complication probabilities (NTCPs). RESULTS: No significant differences in TCPs were found between prostate alignment and potential patient positions (0.944 ± 0.003 vs 0.945 ± 0.003, P = 0.117). The average NTCPs of the rectum ranged from 5.16 to 7.29 (%) among the potential patient positions and were highly influenced by the couch shift in the anterior–posterior direction. In contrast, the average NTCPs of the bladder ranged from 0.75 to 1.12 (%) among the potential patient positions and were relatively negligible. CONCLUSIONS: The NTCPs of the rectum, rather than the TCPs of the target, were highly influenced by the interobserver variability in CBCT-based soft-tissue matching. This study provides a theoretical explanation for daily CBCT-based image guidance and the prostate-rectum interface matching procedure. Trial registration: Not applicable. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-022-02034-1.
format Online
Article
Text
id pubmed-8973574
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-89735742022-04-02 Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy Zhang, Xiangbin Wang, Xin Li, Xiaoyu Zhou, Li Nie, Shihong Li, Changhu Wang, Xuetao Dai, Guyu Deng, Zhonghua Zhong, Renming Radiat Oncol Research BACKGROUND: Prostate alignment is subject to interobserver variability in cone-beam CT (CBCT)-based soft-tissue matching. This study aims to analyze the impact of possible interobserver variability in CBCT-based soft-tissue matching for prostate cancer radiotherapy. METHODS: Retrospective data, consisting of 156 CBCT images from twelve prostate cancer patients with elective nodal irradiation were analyzed in this study. To simulate possible interobserver variability, couch shifts of 2 mm relative to the resulting patient position of prostate alignment were assumed as potential patient positions (27 possibilities). For each CBCT, the doses of the potential patient positions were re-calculated using deformable image registration-based synthetic CT. The impact of the simulated interobserver variability was evaluated using tumor control probabilities (TCPs) and normal tissue complication probabilities (NTCPs). RESULTS: No significant differences in TCPs were found between prostate alignment and potential patient positions (0.944 ± 0.003 vs 0.945 ± 0.003, P = 0.117). The average NTCPs of the rectum ranged from 5.16 to 7.29 (%) among the potential patient positions and were highly influenced by the couch shift in the anterior–posterior direction. In contrast, the average NTCPs of the bladder ranged from 0.75 to 1.12 (%) among the potential patient positions and were relatively negligible. CONCLUSIONS: The NTCPs of the rectum, rather than the TCPs of the target, were highly influenced by the interobserver variability in CBCT-based soft-tissue matching. This study provides a theoretical explanation for daily CBCT-based image guidance and the prostate-rectum interface matching procedure. Trial registration: Not applicable. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-022-02034-1. BioMed Central 2022-04-01 /pmc/articles/PMC8973574/ /pubmed/35365155 http://dx.doi.org/10.1186/s13014-022-02034-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Zhang, Xiangbin
Wang, Xin
Li, Xiaoyu
Zhou, Li
Nie, Shihong
Li, Changhu
Wang, Xuetao
Dai, Guyu
Deng, Zhonghua
Zhong, Renming
Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy
title Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy
title_full Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy
title_fullStr Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy
title_full_unstemmed Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy
title_short Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy
title_sort evaluating the impact of possible interobserver variability in cbct-based soft-tissue matching using tcp/ntcp models for prostate cancer radiotherapy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8973574/
https://www.ncbi.nlm.nih.gov/pubmed/35365155
http://dx.doi.org/10.1186/s13014-022-02034-1
work_keys_str_mv AT zhangxiangbin evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT wangxin evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT lixiaoyu evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT zhouli evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT nieshihong evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT lichanghu evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT wangxuetao evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT daiguyu evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT dengzhonghua evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy
AT zhongrenming evaluatingtheimpactofpossibleinterobservervariabilityincbctbasedsofttissuematchingusingtcpntcpmodelsforprostatecancerradiotherapy