Evaluation of electropolymerized molecularly imprinted polymers (E-MIPs) on disposable electrodes for detection of SARS-CoV-2 in saliva

We investigate electropolymerized molecularly imprinted polymers (E-MIPs) for the selective recognition of SARS-CoV-2 whole virus. E-MIPs imprinted with SARS-CoV-2 pseudoparticles (pps) were electrochemically deposited onto screen printed electrodes by reductive electropolymerization, using the wate...

Descripción completa

Detalles Bibliográficos
Autores principales: EL Sharif, H.F., Dennison, S.R., Tully, M., Crossley, S., Mwangi, W., Bailey, D., Graham, S.P., Reddy, S.M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Author(s). Published by Elsevier B.V. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8974637/
https://www.ncbi.nlm.nih.gov/pubmed/35473858
http://dx.doi.org/10.1016/j.aca.2022.339777
_version_ 1784680244664336384
author EL Sharif, H.F.
Dennison, S.R.
Tully, M.
Crossley, S.
Mwangi, W.
Bailey, D.
Graham, S.P.
Reddy, S.M.
author_facet EL Sharif, H.F.
Dennison, S.R.
Tully, M.
Crossley, S.
Mwangi, W.
Bailey, D.
Graham, S.P.
Reddy, S.M.
author_sort EL Sharif, H.F.
collection PubMed
description We investigate electropolymerized molecularly imprinted polymers (E-MIPs) for the selective recognition of SARS-CoV-2 whole virus. E-MIPs imprinted with SARS-CoV-2 pseudoparticles (pps) were electrochemically deposited onto screen printed electrodes by reductive electropolymerization, using the water-soluble N-hydroxmethylacrylamide (NHMA) as functional monomer and crosslinked with N,N′-methylenebisacrylamide (MBAm). E-MIPs for SARS-CoV-2 showed selectivity for template SARS-CoV-2 pps, with an imprinting factor of 3:1, and specificity (significance = 0.06) when cross-reacted with other respiratory viruses. E-MIPs detected the presence of SARS-CoV-2 pps in <10 min with a limit of detection of 4.9 log(10) pfu/mL, suggesting their suitability for detection of SARS-CoV-2 with minimal sample preparation. Using electrochemical impedance spectroscopy (EIS) and principal component analysis (PCA), the capture of SARS-CoV-2 from real patient saliva samples was also evaluated. Fifteen confirmed COVID-19 positive and nine COVID-19 negative saliva samples were compared against the established loop-mediated isothermal nucleic acid amplification (LAMP) technique used by the UK National Health Service. EIS data demonstrated a PCA discrimination between positive and negative LAMP samples. A threshold real impedance signal (Z(Re)) ≫ 4000 Ω and a corresponding charge transfer resistance (R(CT)) ≫ 6000 Ω was indicative of absence of virus (COVID-19 negative) in agreement with values obtained for our control non-imprinted polymer control. A Z(Re) at or below a threshold value of 600 Ω with a corresponding R(CT) of <1200 Ω was indicative of a COVID-19 positive sample. The presence of virus was confirmed by treatment of E-MIPs with a SARS-CoV-2 specific monoclonal antibody.
format Online
Article
Text
id pubmed-8974637
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Author(s). Published by Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-89746372022-04-04 Evaluation of electropolymerized molecularly imprinted polymers (E-MIPs) on disposable electrodes for detection of SARS-CoV-2 in saliva EL Sharif, H.F. Dennison, S.R. Tully, M. Crossley, S. Mwangi, W. Bailey, D. Graham, S.P. Reddy, S.M. Anal Chim Acta Article We investigate electropolymerized molecularly imprinted polymers (E-MIPs) for the selective recognition of SARS-CoV-2 whole virus. E-MIPs imprinted with SARS-CoV-2 pseudoparticles (pps) were electrochemically deposited onto screen printed electrodes by reductive electropolymerization, using the water-soluble N-hydroxmethylacrylamide (NHMA) as functional monomer and crosslinked with N,N′-methylenebisacrylamide (MBAm). E-MIPs for SARS-CoV-2 showed selectivity for template SARS-CoV-2 pps, with an imprinting factor of 3:1, and specificity (significance = 0.06) when cross-reacted with other respiratory viruses. E-MIPs detected the presence of SARS-CoV-2 pps in <10 min with a limit of detection of 4.9 log(10) pfu/mL, suggesting their suitability for detection of SARS-CoV-2 with minimal sample preparation. Using electrochemical impedance spectroscopy (EIS) and principal component analysis (PCA), the capture of SARS-CoV-2 from real patient saliva samples was also evaluated. Fifteen confirmed COVID-19 positive and nine COVID-19 negative saliva samples were compared against the established loop-mediated isothermal nucleic acid amplification (LAMP) technique used by the UK National Health Service. EIS data demonstrated a PCA discrimination between positive and negative LAMP samples. A threshold real impedance signal (Z(Re)) ≫ 4000 Ω and a corresponding charge transfer resistance (R(CT)) ≫ 6000 Ω was indicative of absence of virus (COVID-19 negative) in agreement with values obtained for our control non-imprinted polymer control. A Z(Re) at or below a threshold value of 600 Ω with a corresponding R(CT) of <1200 Ω was indicative of a COVID-19 positive sample. The presence of virus was confirmed by treatment of E-MIPs with a SARS-CoV-2 specific monoclonal antibody. The Author(s). Published by Elsevier B.V. 2022-05-08 2022-04-01 /pmc/articles/PMC8974637/ /pubmed/35473858 http://dx.doi.org/10.1016/j.aca.2022.339777 Text en © 2022 The Author(s) Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
EL Sharif, H.F.
Dennison, S.R.
Tully, M.
Crossley, S.
Mwangi, W.
Bailey, D.
Graham, S.P.
Reddy, S.M.
Evaluation of electropolymerized molecularly imprinted polymers (E-MIPs) on disposable electrodes for detection of SARS-CoV-2 in saliva
title Evaluation of electropolymerized molecularly imprinted polymers (E-MIPs) on disposable electrodes for detection of SARS-CoV-2 in saliva
title_full Evaluation of electropolymerized molecularly imprinted polymers (E-MIPs) on disposable electrodes for detection of SARS-CoV-2 in saliva
title_fullStr Evaluation of electropolymerized molecularly imprinted polymers (E-MIPs) on disposable electrodes for detection of SARS-CoV-2 in saliva
title_full_unstemmed Evaluation of electropolymerized molecularly imprinted polymers (E-MIPs) on disposable electrodes for detection of SARS-CoV-2 in saliva
title_short Evaluation of electropolymerized molecularly imprinted polymers (E-MIPs) on disposable electrodes for detection of SARS-CoV-2 in saliva
title_sort evaluation of electropolymerized molecularly imprinted polymers (e-mips) on disposable electrodes for detection of sars-cov-2 in saliva
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8974637/
https://www.ncbi.nlm.nih.gov/pubmed/35473858
http://dx.doi.org/10.1016/j.aca.2022.339777
work_keys_str_mv AT elsharifhf evaluationofelectropolymerizedmolecularlyimprintedpolymersemipsondisposableelectrodesfordetectionofsarscov2insaliva
AT dennisonsr evaluationofelectropolymerizedmolecularlyimprintedpolymersemipsondisposableelectrodesfordetectionofsarscov2insaliva
AT tullym evaluationofelectropolymerizedmolecularlyimprintedpolymersemipsondisposableelectrodesfordetectionofsarscov2insaliva
AT crossleys evaluationofelectropolymerizedmolecularlyimprintedpolymersemipsondisposableelectrodesfordetectionofsarscov2insaliva
AT mwangiw evaluationofelectropolymerizedmolecularlyimprintedpolymersemipsondisposableelectrodesfordetectionofsarscov2insaliva
AT baileyd evaluationofelectropolymerizedmolecularlyimprintedpolymersemipsondisposableelectrodesfordetectionofsarscov2insaliva
AT grahamsp evaluationofelectropolymerizedmolecularlyimprintedpolymersemipsondisposableelectrodesfordetectionofsarscov2insaliva
AT reddysm evaluationofelectropolymerizedmolecularlyimprintedpolymersemipsondisposableelectrodesfordetectionofsarscov2insaliva