Cargando…

The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study

BACKGROUND: : Although many studies have suggested that air cells may play an important role in sigmoid sinus diverticulum and/or dehiscence (SSDD)-induced pulsatile tinnitus (PT), the exact effects remain unclear. This study aims to quantitatively investigate the effect of different degrees of pneu...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zhaohui, Liu, Wenjuan, He, Xueying, Li, Wei, Zhang, Lirong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Academy of Otology and Neurotology and the Politzer Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8975400/
https://www.ncbi.nlm.nih.gov/pubmed/34309552
http://dx.doi.org/10.5152/iao.2021.9449
_version_ 1784680372801372160
author Liu, Zhaohui
Liu, Wenjuan
He, Xueying
Li, Wei
Zhang, Lirong
author_facet Liu, Zhaohui
Liu, Wenjuan
He, Xueying
Li, Wei
Zhang, Lirong
author_sort Liu, Zhaohui
collection PubMed
description BACKGROUND: : Although many studies have suggested that air cells may play an important role in sigmoid sinus diverticulum and/or dehiscence (SSDD)-induced pulsatile tinnitus (PT), the exact effects remain unclear. This study aims to quantitatively investigate the effect of different degrees of pneumatization of temporal bone on sound transmission from the sigmoid sinus to the tympanic cavity. METHODS: : In the clinical study, 25 patients were enrolled to measure the sound intensity and frequency of SSDD-induced PT. In the experimental study, sound inputs at different frequencies at the dehiscent sigmoid plate were measured and compared among realistic object models of different degrees of pneumatization, when sound intensity in the tympanic cavity was fixed as the level of the PT sound intensity sensed by patients. RESULTS: : The sound intensity sensed by PT patients was 34.0 ± 13.0 dB SPL, which represented the sound intensity in the tympanic cavity transmitted from the dehiscent sigmoid plate. In the experimental study, when sound received in the tympanic cavity was fixed at 34 dB SPL, the mean inputs of sound intensity at the dehiscent sigmoid plate were 46.9, 46.2, 45.2, 47.1, 57, 57.4, and 74.1 dB SPL in a hypo-pneumatized model; 42.6, 43, 41.5, 43.2, 47.3, 58.2, and 78.8 dB SPL in a moderately pneumatized model; 52.6, 52.8, 48.1, 61, 64.2, 82.4, and >87.3 dB SPL in a well-pneumatized model; and 47.2, 46.2, 45.4, 49.4, 54.9, 66.6, and 77.7 dB SPL in hyper-pneumatized model, with increased sound frequencies (125-8000 Hz). The mean sound transmission distances were 41.7 mm, 45.2 mm, 47.6 mm, and 48.4 mm in successively better pneumatized models. CONCLUSION: : Sound reduces while passing through air cells and attenuation is lowest in the moderately pneumatized temporal bone, followed by the hypo- and hyper-pneumatized temporal bones, and the highest in the well-pneumatized temporal bone. Lower-frequency sound attenuation (≤1000 Hz) is less than that of higher-frequency sound (>1000 Hz).
format Online
Article
Text
id pubmed-8975400
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher European Academy of Otology and Neurotology and the Politzer Society
record_format MEDLINE/PubMed
spelling pubmed-89754002022-04-14 The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study Liu, Zhaohui Liu, Wenjuan He, Xueying Li, Wei Zhang, Lirong J Int Adv Otol Original Article BACKGROUND: : Although many studies have suggested that air cells may play an important role in sigmoid sinus diverticulum and/or dehiscence (SSDD)-induced pulsatile tinnitus (PT), the exact effects remain unclear. This study aims to quantitatively investigate the effect of different degrees of pneumatization of temporal bone on sound transmission from the sigmoid sinus to the tympanic cavity. METHODS: : In the clinical study, 25 patients were enrolled to measure the sound intensity and frequency of SSDD-induced PT. In the experimental study, sound inputs at different frequencies at the dehiscent sigmoid plate were measured and compared among realistic object models of different degrees of pneumatization, when sound intensity in the tympanic cavity was fixed as the level of the PT sound intensity sensed by patients. RESULTS: : The sound intensity sensed by PT patients was 34.0 ± 13.0 dB SPL, which represented the sound intensity in the tympanic cavity transmitted from the dehiscent sigmoid plate. In the experimental study, when sound received in the tympanic cavity was fixed at 34 dB SPL, the mean inputs of sound intensity at the dehiscent sigmoid plate were 46.9, 46.2, 45.2, 47.1, 57, 57.4, and 74.1 dB SPL in a hypo-pneumatized model; 42.6, 43, 41.5, 43.2, 47.3, 58.2, and 78.8 dB SPL in a moderately pneumatized model; 52.6, 52.8, 48.1, 61, 64.2, 82.4, and >87.3 dB SPL in a well-pneumatized model; and 47.2, 46.2, 45.4, 49.4, 54.9, 66.6, and 77.7 dB SPL in hyper-pneumatized model, with increased sound frequencies (125-8000 Hz). The mean sound transmission distances were 41.7 mm, 45.2 mm, 47.6 mm, and 48.4 mm in successively better pneumatized models. CONCLUSION: : Sound reduces while passing through air cells and attenuation is lowest in the moderately pneumatized temporal bone, followed by the hypo- and hyper-pneumatized temporal bones, and the highest in the well-pneumatized temporal bone. Lower-frequency sound attenuation (≤1000 Hz) is less than that of higher-frequency sound (>1000 Hz). European Academy of Otology and Neurotology and the Politzer Society 2021-07-01 /pmc/articles/PMC8975400/ /pubmed/34309552 http://dx.doi.org/10.5152/iao.2021.9449 Text en 2021 authors https://creativecommons.org/licenses/by-nc/4.0/ Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle Original Article
Liu, Zhaohui
Liu, Wenjuan
He, Xueying
Li, Wei
Zhang, Lirong
The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study
title The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study
title_full The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study
title_fullStr The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study
title_full_unstemmed The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study
title_short The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study
title_sort effect of degree of temporal bone pneumatization on sound transmission of pulsatile tinnitus induced by sigmoid sinus diverticulum and/or dehiscence: a clinical and experimental study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8975400/
https://www.ncbi.nlm.nih.gov/pubmed/34309552
http://dx.doi.org/10.5152/iao.2021.9449
work_keys_str_mv AT liuzhaohui theeffectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT liuwenjuan theeffectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT hexueying theeffectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT liwei theeffectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT zhanglirong theeffectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT liuzhaohui effectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT liuwenjuan effectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT hexueying effectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT liwei effectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy
AT zhanglirong effectofdegreeoftemporalbonepneumatizationonsoundtransmissionofpulsatiletinnitusinducedbysigmoidsinusdiverticulumandordehiscenceaclinicalandexperimentalstudy