Cargando…
Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study
BACKGROUND: The test battery classically used for return-to-sport (RTS) decision-making after anterior cruciate ligament (ACL) reconstruction (ACLR) may not be sufficient, as it does not include a qualitative analysis of movement. Therefore, the Landing Error Scoring System (LESS) scale was adapted...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
NASMI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8975581/ https://www.ncbi.nlm.nih.gov/pubmed/35391866 http://dx.doi.org/10.26603/001c.33066 |
_version_ | 1784680394821468160 |
---|---|
author | Measson, Maxime V. Ithurburn, Matthew P. Rambaud, Alexandre JM. |
author_facet | Measson, Maxime V. Ithurburn, Matthew P. Rambaud, Alexandre JM. |
author_sort | Measson, Maxime V. |
collection | PubMed |
description | BACKGROUND: The test battery classically used for return-to-sport (RTS) decision-making after anterior cruciate ligament (ACL) reconstruction (ACLR) may not be sufficient, as it does not include a qualitative analysis of movement. Therefore, the Landing Error Scoring System (LESS) scale was adapted to a primary functional test in the typical RTS test battery: the single leg hop for distance (SHD). HYPOTHESIS/ PURPOSE: The aim of this study was to determine the intra-rater reliability of the LESS scale adapted to the SHD (SHD-LESS scale) in healthy young athletes. STUDY DESIGN: Reliability analysis METHODS: Nineteen healthy individuals (14 men, 5 women; mean age: 22.4 years) participated in the study. Participants performed the SHD tasks on both limbs (dominant and non-dominant) using a standardized protocol in two sessions that were one week apart (single reviewer; 2-dimensional video). Intra-class correlation coefficients (ICC2,1) were used to measure the reproducibility of the scale in the dominant (dom) and non-dominant (nondom) limbs. Additionally, limb data (dom and nondom) were pooled and evaluated collectively with intra-class correlation coefficients. The Kappa coefficient was used to assess the reproducibility of each individual item of SHD-LESS scale. RESULTS: The intra-rater reliability was good (ICCdom = 0.77; ICCnondom = 0.87; ICCpooled = 0.87) for the overall SHD-LESS scale scores. Agreement of SHD-LESS individual items ranged from 62% to 100%. Dorsiflexion at initial contact (97% agreement; kappa value=0.79) and knee valgus after landing (88% agreement; kappa value=0.65) had excellent agreement and kappa values. CONCLUSION: The newly-adapted SHD-LESS scale showed good intra-rater reliability overall. Further studies should evaluate the impact of using the SHD-LESS scale within the RTS test battery on outcomes in patients after ACLR. LEVEL OF EVIDENCE: 3 |
format | Online Article Text |
id | pubmed-8975581 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | NASMI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89755812022-04-06 Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study Measson, Maxime V. Ithurburn, Matthew P. Rambaud, Alexandre JM. Int J Sports Phys Ther Original Research BACKGROUND: The test battery classically used for return-to-sport (RTS) decision-making after anterior cruciate ligament (ACL) reconstruction (ACLR) may not be sufficient, as it does not include a qualitative analysis of movement. Therefore, the Landing Error Scoring System (LESS) scale was adapted to a primary functional test in the typical RTS test battery: the single leg hop for distance (SHD). HYPOTHESIS/ PURPOSE: The aim of this study was to determine the intra-rater reliability of the LESS scale adapted to the SHD (SHD-LESS scale) in healthy young athletes. STUDY DESIGN: Reliability analysis METHODS: Nineteen healthy individuals (14 men, 5 women; mean age: 22.4 years) participated in the study. Participants performed the SHD tasks on both limbs (dominant and non-dominant) using a standardized protocol in two sessions that were one week apart (single reviewer; 2-dimensional video). Intra-class correlation coefficients (ICC2,1) were used to measure the reproducibility of the scale in the dominant (dom) and non-dominant (nondom) limbs. Additionally, limb data (dom and nondom) were pooled and evaluated collectively with intra-class correlation coefficients. The Kappa coefficient was used to assess the reproducibility of each individual item of SHD-LESS scale. RESULTS: The intra-rater reliability was good (ICCdom = 0.77; ICCnondom = 0.87; ICCpooled = 0.87) for the overall SHD-LESS scale scores. Agreement of SHD-LESS individual items ranged from 62% to 100%. Dorsiflexion at initial contact (97% agreement; kappa value=0.79) and knee valgus after landing (88% agreement; kappa value=0.65) had excellent agreement and kappa values. CONCLUSION: The newly-adapted SHD-LESS scale showed good intra-rater reliability overall. Further studies should evaluate the impact of using the SHD-LESS scale within the RTS test battery on outcomes in patients after ACLR. LEVEL OF EVIDENCE: 3 NASMI 2022-04-01 /pmc/articles/PMC8975581/ /pubmed/35391866 http://dx.doi.org/10.26603/001c.33066 Text en https://creativecommons.org/licenses/by-nc/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (4.0) (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Original Research Measson, Maxime V. Ithurburn, Matthew P. Rambaud, Alexandre JM. Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study |
title | Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study |
title_full | Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study |
title_fullStr | Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study |
title_full_unstemmed | Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study |
title_short | Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study |
title_sort | intra-rater reliability of a qualitative landing scale for the single-hop test: a pilot study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8975581/ https://www.ncbi.nlm.nih.gov/pubmed/35391866 http://dx.doi.org/10.26603/001c.33066 |
work_keys_str_mv | AT meassonmaximev intraraterreliabilityofaqualitativelandingscaleforthesinglehoptestapilotstudy AT ithurburnmatthewp intraraterreliabilityofaqualitativelandingscaleforthesinglehoptestapilotstudy AT rambaudalexandrejm intraraterreliabilityofaqualitativelandingscaleforthesinglehoptestapilotstudy |