Cargando…

Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial

BACKGROUND: Double lumen tube (DLT) intubation is the most commonly used technique for one lung ventilation. Bronchial blockers (BB) are an alternative, especially for difficult airways. The EZ-bronchial blocker (EZB) is an innovative y-shaped and double-ended device of the BB family. METHODS: A ran...

Descripción completa

Detalles Bibliográficos
Autores principales: Risse, Joachim, Szeder, Karsten, Schubert, Ann-Kristin, Wiesmann, Thomas, Dinges, Hanns-Christian, Feldmann, Carsten, Wulf, Hinnerk, Meggiolaro, Karl Matteo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8976407/
https://www.ncbi.nlm.nih.gov/pubmed/35366801
http://dx.doi.org/10.1186/s12871-022-01637-1
_version_ 1784680566146203648
author Risse, Joachim
Szeder, Karsten
Schubert, Ann-Kristin
Wiesmann, Thomas
Dinges, Hanns-Christian
Feldmann, Carsten
Wulf, Hinnerk
Meggiolaro, Karl Matteo
author_facet Risse, Joachim
Szeder, Karsten
Schubert, Ann-Kristin
Wiesmann, Thomas
Dinges, Hanns-Christian
Feldmann, Carsten
Wulf, Hinnerk
Meggiolaro, Karl Matteo
author_sort Risse, Joachim
collection PubMed
description BACKGROUND: Double lumen tube (DLT) intubation is the most commonly used technique for one lung ventilation. Bronchial blockers (BB) are an alternative, especially for difficult airways. The EZ-bronchial blocker (EZB) is an innovative y-shaped and double-ended device of the BB family. METHODS: A randomised, controlled trial was conducted in 80 patients undergoing elective thoracic surgery using DLT or EZB for one lung ventilation (German Clinical Trial Register DRKS00014816). The objective of the study was to compare the clinical performance of EZB with DLT. Primary endpoint was total time to obtain successful one lung ventilation. Secondary endpoints were time subsections, quality of lung collapse, difficulty of intubation, any complications during the procedure, incidence of objective trauma of the oropharynx and supraglottic space and intubation-related subjective symptoms. RESULTS: 74 patients were included, DLT group (n = 38), EZB group (n = 36). Median total time to obtain one lung ventilation [IQR] in the DLT group was 234 s [207 to 294] versus 298 s [243 to 369] in the EZB group (P = 0.007). Median total time was relevantly influenced by different preparation times. Quality of lung collapse was equal in both groups, DLT group 89.5% were excellent vs. 83.3% in the EZB group (P = 0.444). Inadequate lung collapse in five patients of the EZB group resulted in unsuccessful repositioning attempts and secondary DLT placement. Endoscopic examinations revealed significantly more carina trauma (P = 0.047) and subglottic haemorrhage (P = 0.047) in the DLT group. Postoperative subjective symptoms (sore throat, hoarseness) were more common in the DLT group, as were speech problems. CONCLUSIONS: Using EZB prima facie results in prolonged time to obtain one lung ventilation with equal quality of lung collapse for the thoracic surgeon. If preparation times are omitted in the analysis, the time difference is statistically and clinically not relevant. Our data showed only little evidence for reducing objective airway trauma as well as subjective complaints. In summary both procedures were comparable in terms of times and clinical applicability. Therefore decisions for DLT or EZB should depend more on individual experience, in-house equipment and the individual patient, than on any times that are neither clinically significant nor relevant. TRIAL REGISTRATION: German Clinical Trial Register DRKS00014816, prospectively registered on 07.06.2018
format Online
Article
Text
id pubmed-8976407
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-89764072022-04-03 Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial Risse, Joachim Szeder, Karsten Schubert, Ann-Kristin Wiesmann, Thomas Dinges, Hanns-Christian Feldmann, Carsten Wulf, Hinnerk Meggiolaro, Karl Matteo BMC Anesthesiol Research BACKGROUND: Double lumen tube (DLT) intubation is the most commonly used technique for one lung ventilation. Bronchial blockers (BB) are an alternative, especially for difficult airways. The EZ-bronchial blocker (EZB) is an innovative y-shaped and double-ended device of the BB family. METHODS: A randomised, controlled trial was conducted in 80 patients undergoing elective thoracic surgery using DLT or EZB for one lung ventilation (German Clinical Trial Register DRKS00014816). The objective of the study was to compare the clinical performance of EZB with DLT. Primary endpoint was total time to obtain successful one lung ventilation. Secondary endpoints were time subsections, quality of lung collapse, difficulty of intubation, any complications during the procedure, incidence of objective trauma of the oropharynx and supraglottic space and intubation-related subjective symptoms. RESULTS: 74 patients were included, DLT group (n = 38), EZB group (n = 36). Median total time to obtain one lung ventilation [IQR] in the DLT group was 234 s [207 to 294] versus 298 s [243 to 369] in the EZB group (P = 0.007). Median total time was relevantly influenced by different preparation times. Quality of lung collapse was equal in both groups, DLT group 89.5% were excellent vs. 83.3% in the EZB group (P = 0.444). Inadequate lung collapse in five patients of the EZB group resulted in unsuccessful repositioning attempts and secondary DLT placement. Endoscopic examinations revealed significantly more carina trauma (P = 0.047) and subglottic haemorrhage (P = 0.047) in the DLT group. Postoperative subjective symptoms (sore throat, hoarseness) were more common in the DLT group, as were speech problems. CONCLUSIONS: Using EZB prima facie results in prolonged time to obtain one lung ventilation with equal quality of lung collapse for the thoracic surgeon. If preparation times are omitted in the analysis, the time difference is statistically and clinically not relevant. Our data showed only little evidence for reducing objective airway trauma as well as subjective complaints. In summary both procedures were comparable in terms of times and clinical applicability. Therefore decisions for DLT or EZB should depend more on individual experience, in-house equipment and the individual patient, than on any times that are neither clinically significant nor relevant. TRIAL REGISTRATION: German Clinical Trial Register DRKS00014816, prospectively registered on 07.06.2018 BioMed Central 2022-04-02 /pmc/articles/PMC8976407/ /pubmed/35366801 http://dx.doi.org/10.1186/s12871-022-01637-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Risse, Joachim
Szeder, Karsten
Schubert, Ann-Kristin
Wiesmann, Thomas
Dinges, Hanns-Christian
Feldmann, Carsten
Wulf, Hinnerk
Meggiolaro, Karl Matteo
Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial
title Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial
title_full Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial
title_fullStr Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial
title_full_unstemmed Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial
title_short Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial
title_sort comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery—a randomised controlled clinical trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8976407/
https://www.ncbi.nlm.nih.gov/pubmed/35366801
http://dx.doi.org/10.1186/s12871-022-01637-1
work_keys_str_mv AT rissejoachim comparisonofleftdoublelumentubeandyshapedanddoubleendedbronchialblockerforonelungventilationinthoracicsurgeryarandomisedcontrolledclinicaltrial
AT szederkarsten comparisonofleftdoublelumentubeandyshapedanddoubleendedbronchialblockerforonelungventilationinthoracicsurgeryarandomisedcontrolledclinicaltrial
AT schubertannkristin comparisonofleftdoublelumentubeandyshapedanddoubleendedbronchialblockerforonelungventilationinthoracicsurgeryarandomisedcontrolledclinicaltrial
AT wiesmannthomas comparisonofleftdoublelumentubeandyshapedanddoubleendedbronchialblockerforonelungventilationinthoracicsurgeryarandomisedcontrolledclinicaltrial
AT dingeshannschristian comparisonofleftdoublelumentubeandyshapedanddoubleendedbronchialblockerforonelungventilationinthoracicsurgeryarandomisedcontrolledclinicaltrial
AT feldmanncarsten comparisonofleftdoublelumentubeandyshapedanddoubleendedbronchialblockerforonelungventilationinthoracicsurgeryarandomisedcontrolledclinicaltrial
AT wulfhinnerk comparisonofleftdoublelumentubeandyshapedanddoubleendedbronchialblockerforonelungventilationinthoracicsurgeryarandomisedcontrolledclinicaltrial
AT meggiolarokarlmatteo comparisonofleftdoublelumentubeandyshapedanddoubleendedbronchialblockerforonelungventilationinthoracicsurgeryarandomisedcontrolledclinicaltrial