Cargando…

Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study

OBJECTIVES: Evaluation of the safety and efficacy of the Penumbra device as an adjunct to percutaneous coronary intervention (PCI) in patients with myocardial infarction (MI) and a large thrombus burden that requires thrombectomy. BACKGROUND: For patients with acute MI, PCI is the primary reperfusio...

Descripción completa

Detalles Bibliográficos
Autores principales: Tashtish, Nour, Chami, Tarek, Dong, Tony, Chami, Besher, Al-Kindi, Sadeer, Mously, Haytham, Janus, Scott, Hammad, Tarek, Shishehbor, Mehdi H., Gupta, Anjan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8976598/
https://www.ncbi.nlm.nih.gov/pubmed/35401062
http://dx.doi.org/10.1155/2022/5692964
_version_ 1784680610563883008
author Tashtish, Nour
Chami, Tarek
Dong, Tony
Chami, Besher
Al-Kindi, Sadeer
Mously, Haytham
Janus, Scott
Hammad, Tarek
Shishehbor, Mehdi H.
Gupta, Anjan
author_facet Tashtish, Nour
Chami, Tarek
Dong, Tony
Chami, Besher
Al-Kindi, Sadeer
Mously, Haytham
Janus, Scott
Hammad, Tarek
Shishehbor, Mehdi H.
Gupta, Anjan
author_sort Tashtish, Nour
collection PubMed
description OBJECTIVES: Evaluation of the safety and efficacy of the Penumbra device as an adjunct to percutaneous coronary intervention (PCI) in patients with myocardial infarction (MI) and a large thrombus burden that requires thrombectomy. BACKGROUND: For patients with acute MI, PCI is the primary reperfusion method. Large thrombus burden has always been a limitation of successful reperfusion. However, the use of current aspiration devices has been associated with an increased incidence of stroke. METHODS: We performed a retrospective chart review at the University Hospitals Medical Center in Cleveland. Our study included data from patients who underwent PCI for ST segment elevation myocardial infarction (STEMI) and non-ST segment elevation myocardial infarction (NSTEMI) assisted by the Penumbra Cat RX device (a wide-lumen thrombus aspiration catheter) between May 2019 and February 2021. The primary outcome was the final thrombolysis in myocardial infarction (TIMI) flow. The secondary endpoints were a composite of adverse cardiac events at 6 months. About 50% of the patients did undergo transfemoral PCI as per preference of individual operators. The Penumbra thrombectomy device can be used both by radial and femoral approach and does not need any different guide catheter use. RESULTS: TIMI flow 3 was achieved in 111 patients (90.2%). The secondary endpoint occurred in 11 patients (8.9%, 3 MI, 8 heart failure hospitalizations). There were no stroke events or device-related complications. The door-to-balloon time was not affected by usage of the Penumbra device. Failure in the restoration of TIMI 3 flow was associated with the use of balloon angioplasty prior to the application of the Penumbra device, leading to distal embolization. CONCLUSIONS: The Penumbra Cat RX provides safe and effective thrombus removal with better clinical outcomes, even in high-risk patients with acute coronary syndrome.
format Online
Article
Text
id pubmed-8976598
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-89765982022-04-08 Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study Tashtish, Nour Chami, Tarek Dong, Tony Chami, Besher Al-Kindi, Sadeer Mously, Haytham Janus, Scott Hammad, Tarek Shishehbor, Mehdi H. Gupta, Anjan J Interv Cardiol Research Article OBJECTIVES: Evaluation of the safety and efficacy of the Penumbra device as an adjunct to percutaneous coronary intervention (PCI) in patients with myocardial infarction (MI) and a large thrombus burden that requires thrombectomy. BACKGROUND: For patients with acute MI, PCI is the primary reperfusion method. Large thrombus burden has always been a limitation of successful reperfusion. However, the use of current aspiration devices has been associated with an increased incidence of stroke. METHODS: We performed a retrospective chart review at the University Hospitals Medical Center in Cleveland. Our study included data from patients who underwent PCI for ST segment elevation myocardial infarction (STEMI) and non-ST segment elevation myocardial infarction (NSTEMI) assisted by the Penumbra Cat RX device (a wide-lumen thrombus aspiration catheter) between May 2019 and February 2021. The primary outcome was the final thrombolysis in myocardial infarction (TIMI) flow. The secondary endpoints were a composite of adverse cardiac events at 6 months. About 50% of the patients did undergo transfemoral PCI as per preference of individual operators. The Penumbra thrombectomy device can be used both by radial and femoral approach and does not need any different guide catheter use. RESULTS: TIMI flow 3 was achieved in 111 patients (90.2%). The secondary endpoint occurred in 11 patients (8.9%, 3 MI, 8 heart failure hospitalizations). There were no stroke events or device-related complications. The door-to-balloon time was not affected by usage of the Penumbra device. Failure in the restoration of TIMI 3 flow was associated with the use of balloon angioplasty prior to the application of the Penumbra device, leading to distal embolization. CONCLUSIONS: The Penumbra Cat RX provides safe and effective thrombus removal with better clinical outcomes, even in high-risk patients with acute coronary syndrome. Hindawi 2022-03-26 /pmc/articles/PMC8976598/ /pubmed/35401062 http://dx.doi.org/10.1155/2022/5692964 Text en Copyright © 2022 Nour Tashtish et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Tashtish, Nour
Chami, Tarek
Dong, Tony
Chami, Besher
Al-Kindi, Sadeer
Mously, Haytham
Janus, Scott
Hammad, Tarek
Shishehbor, Mehdi H.
Gupta, Anjan
Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study
title Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study
title_full Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study
title_fullStr Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study
title_full_unstemmed Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study
title_short Routine Use of the “Penumbra” Thrombectomy Device in Myocardial Infarction: A Real-World Experience—ROPUST Study
title_sort routine use of the “penumbra” thrombectomy device in myocardial infarction: a real-world experience—ropust study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8976598/
https://www.ncbi.nlm.nih.gov/pubmed/35401062
http://dx.doi.org/10.1155/2022/5692964
work_keys_str_mv AT tashtishnour routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT chamitarek routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT dongtony routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT chamibesher routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT alkindisadeer routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT mouslyhaytham routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT janusscott routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT hammadtarek routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT shishehbormehdih routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy
AT guptaanjan routineuseofthepenumbrathrombectomydeviceinmyocardialinfarctionarealworldexperienceropuststudy